![Alfa level LKH UltraPure-10 Instruction Manual Download Page 21](http://html1.mh-extra.com/html/alfa-level/lkh-ultrapure-10/lkh-ultrapure-10_instruction-manual_2895203021.webp)
5 Maintenance
Read the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
5.3
Dismantling of pump/shaft seals
Step 1
Flushing set for double mechanical shaft seal:
1. Remove flow meter.
2. Remove flushing set (54) from pump casing (29) and lower tube.
3007-0096
Step 2
Unscrew cap nuts (24) and remove washers (24a) and pump
casing (29).
3001-0020_1
Step 3
Double mechanical shaft seal:
Unscrew tubes (42) using a spanner.
3001-0021