3 Operation
Study the instructions carefully and pay special attention to the warnings!
Ensure that the Steam Generator operates smoothly.
The items refer to the parts list and service kits section.
Step 3
1. Unscrew the tank cap (C) and fill the tank with water (maximum
volume is 1L)
2. Mount the tank cap (C) (tighten by hand)
B = Sight glass for water level
C
B
2900-0143
Step 4
1. Open the gas valve (D).
2. Press and hold the safety valve (E) while pressing the ignition
switch (F). Release the safety valve (E) 5 seconds after the
flame is initiated.
3. Wait until the tank pressure reaches 3 bars.
D
2900-0144
F
E
8