5 Technical data
It is important to observe the technical data during installation, operation and maintenance.
Inform personnel about the technical data.
5.1
Technical data
Attention!
Never touch the Steam Generator or the pipelines when processing hot liquids or when
sterilising.
Never service the Steam Generator when it is hot.
Danger of burns!
Technical data
Max. working pressure
350 kPa (3.5 bar)
Max. working temperature
130 °C
Weight
12 kg
Capacity
Tank volume
1.1 L
Total steam time (full tank, 2 bar)
15 mins.
Steam time for sterilisation (2 bar)
2 mins.
Start-up time (full tank)
10-12 mins.
Materials
Water container and pipes
1.4404 (316L)
Steam hose
Inside: NBR food grade
Outside: NBR/PVC
Pistol handle
Brass
Other parts
PA 6.6 30% GF, aluminium, copper
Spare parts
Spare parts
See section 6 Parts list and service kit