4 Installation
All position numbers and item numbers refer to the drawings shown and specified in chapter 8.1 IMXD without middle
section and 8.2 IMXD with middle section.
Step 10
1. The oil vent plugs are removed on the gear motor (see chapter 9.3 Drive unit instructions).
4306-0019
Step 11
Attach electrical motor to frequency converter (see chapter 9.3 Drive unit instructions for connection of cables to the electrical
motor).
NOTE
If an alternative frequency converter is used the ramp up shall be set to 8 sec and the maximum output voltage to 60%
of max voltage on electrical motor.
Installation of the (IMXD) is completed by attaching the supply lines to the flange connections of the DN125 and DN80 valve body.
The gear motor shall be limited to run between 10 and 50Hz.
18
Summary of Contents for IsoMix External Drive
Page 1: ...100000727 EN1 2018 11 Original manual Instruction Manual Alfa Laval IsoMix External Drive IMXD...