4 Installation
Digital version – PNP
Supply voltage
Supply voltage
24 VDC ± 10%
Max. power consumption of the sensor unit
Solenoid valve not active
50mA
Solenoid valve active
65mA
Output signals from the sensor unit to the connected digital interface (PLC).
Nominal voltage
Same as connected to the Unique Control
Load current
50 mA typical, 100 mA max
Voltage drop
Typical 3V @ 50 mA
Electrical connection for digital version (PNP)
Solenoid
Solenoid common (black)
Internal connections (1, 2)
Supply 24 VDC
Supply 0 VDC
Power supply (3, 4)
De-energised valve
Energised valve
PLC input signals (5, 6, 7)
Pressure alarm
Solenoid valve
PLC output signal (8)
2109-0042
1
3
4
2
5
7
8
6
14
Summary of Contents for ESE02126-EN