4 Installation
Step 4
Lift off the control head and be aware that the 4 O-rings (E) remain
in the grooves.
2109-0032
E
E
Step 5
Turn the control head 180 degrees and check that the marking (F)
is aligned with the NO symbol.
2109-0033
F
Step 6
Re-attach the control head to the actuator by tightening the 4
screws (G) with a tightening torque of 2Nm.
2109-0034
G
G
Step 7
Reconnect the air supply and re-power the Unique Control to
complete the change.