3 Installation
The instruction manual is part of delivery. Study the instructions carefully.
The Agitator is for permanent fastening.
Make sure the motor corresponds to the environment.
Check the direction of rotation before operation.
Step 8
3.4.5 See illustrations, 7.1, 7.2, and 7.5.3.
The Mechanical seal pos. 28 (28.1, 28.2, 28.3, 28.4, 28.5, 28.6) consist of several parts as labelled below – the parts cannot be
ordered separately – only as one complete mechanically seal pos. 28.
A. Add some food-approved grease to the O-ring pos. 28.2 and mount it on the stationary seal ring pos. 28.1.
B. Press both parts (pos. 28.1 and pos. 28.2) into the “Flange, Upper” pos. 5.
C. Add some food-approved grease to the O-ring pos. 28.4 and slides the parts pos. 28.3, 28.4, 28.6 and 28.5 onto the shaft.
D. Mount the “Flange, Upper” pos. 5 onto the “Console for Agitator” pos. 4 – ensure that it is positioned rotation-wise
as required.
E. Press in the two “Guide Pin” pos. 12.
F. Add some Loctite
®
to the four screws pos. 19, mount them with the “Washers” pos. 16 and tighten the screws sequentially
to 51 Nm.
G. Mount the “Parallel Key” pos. 78 using the “Screw” pos. 79.
Figure 9, Greasing 28.4
Figure 11, 28.1 and 28.2
Figure 10, 28.1, 28.1 and 5