8
Transportation, storage and disposal
8.3.4
Removing the preservation
Aids:
-
Solvent
-
Steam-jet cleaning device with
wax-dissolving additives
!
WARN
ING
Risk of injury through emitted preservative
oil.
Wear protective clothing during all the work.
Remove the blind flange with caution to relieve any
pressure inside the pump.
Collect the emitted oil safely and dispose of it in an
environmentally compatible manner.
1.
Clean the outside of the pump with
solvents, if necessary using a steam-jet
cleaning device.
2.
Remove the blind flange on the pressure
side.
3.
Drain the pump, collecting the preservative
oil in a suitable vessel.
4.
Remove the blind flange on the suction
side.
5.
To remove the residual oil, rinse the pump
with the pumped liquid.
8.4
Disposing of the pump
Aids:
-
Solvents or industrial cleaners suitable for
the pumped liquid
53