![Alfa Laval ALP 15-85 Manual Download Page 27](http://html1.mh-extra.com/html/alfa-laval/alp-15-85/alp-15-85_manual_2895164027.webp)
5
Maintenance
5.
Loosen the connecting screws 914.2
between the pump 001 and adapter
housing 180 and remove the adapter
housing, see Fig. 3.
6.
Loosen the fixing screw on the pump-side
coupling half 052.1 and remove the
coupling half using suitable mounting
levers.
Installing the coupling
1.
Slide the pump-side coupling half 052.1
onto the shaft until it stops. Heating the
coupling to 80–100 °C facilitates mounting.
Tighten the fixing screw of the coupling half.
2.
Place the adapter housing 180 on the pump
and tighten the connecting screws 914.2,
see Fig. 4.
X027201A
3.
Measure and write down the distance X
between the face of the coupling and the
connecting surface of the adapter housing,
see Fig. 5.
X027211A
27
Summary of Contents for ALP 15-85
Page 6: ... ...
Page 8: ...1 EC Declaration of Conformity ...
Page 10: ...2 Warning signs in text ...
Page 18: ...3 Function Description ...
Page 22: ...4 Fault Finding ...
Page 36: ...6 Technical Data 6 4 1 Dimension drawing of ALP pump and pump unit X027341A 36 ...
Page 40: ...6 Technical Data ...