OPERATING INSTRUCTIONS
31
of
38
www.alfalaval.com
7.4.0 Disconnecting the CIP-unit
STEP 1
– Disconnecting HE form CIP unit
When disconnecting the hoses from the CIP-unit, inspect them for visible damages.
Avoid damaging the electrical cables, or the inlets and outlets of the unit.
STEP 2
– Rinsing CIP unit
Turn the valves to the following positions and fill the tank (in case of CIP 400L both
tanks) to 1/3 with fresh water. Start the pump for about 3 minutes. Stop the pump.
Valve tag
number
Status
V01
Open
V02
Open
V03
Closed
V04
Closed
V05
Closed
V07 (tank)
Open
V08
Closed
V11
Closed
STEP 3
– Draining CIP unit
When opening valve V11, if there is no hose connected to this valve, make sure that
a collection vessel is placed below to avoid spillage of residual liquid
Turn the valves to position according to below description. After securing tank
drainage, open V06 and drain the unit
Valve tag
number
Status
V01
Open
V02
Open
V03
Open
V04
Open
V05
Open
V07 (tank)
Open
V08
Open
V11
Open