7
Operating instructions
To check the actual flow, proceed as follows:
When the oil temperature has reached the set
point, check the throughput of the separated oil.
100 - 120 l/h is recommended. With this flow the
enclosed filler cup will be filled within 35 - 40
seconds. Proceed as follows:
-
Stop the pump.
G0912611
-
Loosen the return hose fitted to the oil tank
and connect the special return pipe.
-
Start the pump and fill the cup.
-
When the cap is filled, stop the pump and
pour the oil back into the oil tank.
-
Start the pump.
G0912431
Return pipe
44