8
Trouble shooting
8.16 Separation temperature too low
Possible cause
Action
Throughput too high
Reduce the flow
8.17 Heater trips
Possible cause
Action
Thermoswitch TS tripped (located in heater
control cabinet)
Reset the thermoswitch
8.18 Oil leaks from heater
Possible cause
Action
Oil leaking from heater
Remove the cover and tighten the four screws
holding the electric cartridges.