20/30
ALFA IN a.s. ©
www.alfain.eu
3. Press the encoder
V5
to confirm the change.
4. Press any button, or after 10 s, to exit the menu without saving changes.
5. Secondary parameters are common for methods manual and synergy.
Synergy method allows to set more secondary parameters.
Symbol
Meaning
Range (Default)
Mark
ISP
(Initial speed)
Approaching speed
10 - 100 % (30 %)
PrG
(Pre gas time)
Pre gas
0 - 20 s (0,1 s)
PoG
(Post gas time)
Post gas
0 - 20 s (0,5 s)
brn
(Burn back)
Burn back
0 - 150 ms (50 ms)
SCu
(Start current)
Start current
10 - 200 % (130 %)
2, 4
bCu
(Bilevel current)
Second current
10 - 200 % (100 %
= turned off)
2, 4
ECu
(End current)
End current
10 - 200 % (70 %)
2, 4
tuP
(Time UP)
Time up
0,1 - 10,0 s (0,1 s)
2, 4
tdo
(Time DOWN)
Time down
0,1 - 10,0 s (0,1 s)
2, 4
t S
(Time START)
Time of start current 0,1 - 10,0 s (0,1 s)
2
t E
(Time END)
Time of end current
0,1 - 10,0 s (0,1 s)
2
CAL
(Calibration menu)
Calibration menu
x.xx (version sw
PCB engine)
(*)
The last menu item is
CAL
– it is used to enter the calibration menu, which is
intended only for authorized service.
Parameters marked as 2 are available only in 2T stairs mode.
Parameters marked as 4 are available only in 4T stairs mode.
WELDING HOURS COUNTER
If you enter to secondary parameters menu, you can always display this value.
By long-pressing the button
V4 (1)
will be displayed the welding time in hours.
CALIBRATION MENU
u-l
Calibration of voltage and current (password protected -
intended for authorized service)
Cu1
Cooling unit oFF/on/Aut
Cu2
Flow sensor
1 – pressure switch / flow sensor
2 – flowmeter (Hall-Effect)
Cor
Zeroing of the correction (YES = zeroing of the correction
when is changed the output value in the synergic mode)
CrE
See CALIBRATION OF THE WELDING CIRCUIT
By long-pressing the button
V4 (1)