17/30
ALFA IN a.s. ©
www.alfain.eu
1. Left display
V10
shows SYN, right display
V11
shows the number of
synergistic curve.
2. Selects the synergic curve (program number) using the encoder
V16
according to the table, which is located inside. To confirm the program
number press the encoder
V5
.
3. If you press any button other than
V5
, or after 10 s, you exit the menu.
CALIBRATION OF THE WELDING CIRCUIT
Welding features of the synergic curve depends on many factors, for example:
on the torch length, ground cable length, qrounding quality, weldment distance
from the grounding place etc. Therefore, it is appropriate to perform the
calibration of the welding circuit for actual welding conditions.
1. Simultaneously press
V20
and
V5
encoder and you will enter the menu for
secondary parameters.
2. Choose CAL parameter by the encoder
V5
and press it to confirm.
3. Set CrE by the encoder
V5
and press it to confirm.
4. Unscrew the gas nozzle of the welding torch.
5. Cut off the welding wire tightly at the welding jet.
6. Piece of the welding wire (about 50 mm) give to the wire feeder.
In the current jet cannot be now any welding wire.
7. Place the welding tip of welding torch on a clean or cleaned place of the
workpiece by the gentle pressure, press and hold the torch button for 2 s.
For a moment flows the short-circuit current. Short-circuit current helps to
determine and screen the new resistence. (Value can be from 0 mΩ to 60
mΩ – for users aren’t these values important, factory reset CrE = 10 mΩ,
you can set this value by the encoder
V16
).
8. Right display
V11
shows
Err
, if an error occurs. You must repeat the
measurement.
9. Screw back the gas nozzle of the welding torch.
10.
Insert the welding wire.
QUICK SETTING THE JOB - MEMORY
Works for all welding methods.
1. Long press (4s) one of the buttons
V4
(1,2,3,4,5,6) to save set parameters
to memory.
2. Short press one of the buttons
V4
(1,2,3,4,5,6) to load parameters from
memory.
3. Display shows
no Job
, if at the desired position isn’t saved any JOB.