CONNECTIONS
BAT1 Li.Poli 7.4V
BAT2 Li.Poli 7.4V
BATTERY INPUT 1
BATTERY INPUT 2
REDUNDANT POWER SUPPLY OUTPUTS
OUTPUT 1 STABILIZED
OUTPUT 2 STABILIZED
Before using the Double Voltage select on the back side of the device the output voltage suitable for receiver and servos in your possession.
With both batteries connected to the Double Voltage (in “BAT1” and “BAT2” inputs) press the button and keep it pressed for at least two
seconds; when LEDs light on, release the button.
Once turned on the system activates the two outputs “OUT1” and “OUT2” and LEDs start to flash at different frequences according to the
batteries status.
If one battery is discharged or missing, the LED is steady on (See the paragraph “Batteries status”).
With the device turned on, press the button and keep it pressed for at least two seconds for turning it off.
As soon as the button is pressed the LEDs become steady on and after two seconds they turn off, at this point you can release the button and
the device is off.
Note:
Before turning the device off or at the end of a session of use, is always recommended to check the batteries status as the system keeps
memory of the lowest voltage recorded during the last session. When you turn the device off this value is resetted.
TURNING ON:
TURNING OFF:
ATTENTION: WHEN YOU CONNECT THE FIRST BATTERY, THE DEVICE AUTOMATICALLY TURNS ON (THIS IS BECAUSE IF THERE WAS AN UNSTEADY
CONTACT AND POWER SUPPLY WERE CUT OFF, AT THE RETURNING OF POWER THE DEVICE WOULD TURN ON AUTONOMOUSLY). IT IS
THEREFORE NECESSARY, AFTER CONNECTING THE FIRST BATTERY, TO TURN THE DEVICE OFF AND ON AGAIN TO RESET THE BATTERY STATUS
INDICATORS
ATTENTION: if you won’t be using the device for more than 1 week, disconnect batteries from the device.
USAGE
Summary of Contents for DoubleVoltage
Page 6: ...EXAMPLE OK KO EXAMPLE ...
Page 7: ...OK KO EXAMPLE EXAMPLE ...