rF Mode (Standard Pre-Selection Mode)
Work Order Validation via the dispense Keypad
0.00
L
7.2
Dispensed
Quantity
RF COM
Batch Size
When the battery pack is attached to the meter, the meter will
automatically enter the RF mode. the trigger is in a locked-out
position and no oil can be dispensed until a dispense order is
received by the meter.
1. Press the
rESET
button on the meter to enable it to receive a dispense order provided by the dispense Keypad. the
trigger will unlock.
2. Pull the trigger to begin the dispensing of luid. the valve will automatically lock in place, even though the trigger will fall
back to the closed position. the low will automatically shut of when the programmed amount has been dispensed.
3. to top of, pull the trigger to dispense luid and release when the desired amount has been reached.
4. Press the
rESET
button when inished. the total quantity will be transmitted to the keypad and the meter will return to a
locked-out position. the meter is now ready to receive the next dispense order from the keypad.
10 sec
02
Result s tored in
Dispense Keypad
Preselection : Pull the trigger until it
latches and RELEASE the trigger.
No pres election (0 liter): Pull and HOLD
the trigger. The trigger won´t latch.
Press the
RESET button
Press the
RESET button
The red button will STOP
a dispense at any time.
Order stored in
Dispense Keypad
10 sec
02
CLACK
02
Fluid Management System
Page 32
Alemite LLC
Revision (09-13)
SER RFC-PLUS