3500W Digital Inverter with Pure Sine Wave
AFTER SALES SUPPORT
e-mail: [email protected]
1800 909 909
MODEL: №. INF3800A • 03/2016 • 52299
(toll free)
18
AFTER SALES SUPPORT
(toll free)
3500W Digital Inverter with Pure Sine Wave
e-mail: [email protected]
1800 909 909
MODEL: №.
INF3800A • 03/2016 • 52299
Indicators
Indicators
This generator has three main LED indicators to indicate to the operator
various conditions as follows:
1. Low oil indicator (Fig L)
The low oil indicator light (7) is a yellow LED and will illuminate when the
oil level of the generator is too low. The generator will stop operating
within 10 seconds if the yellow light comes on. If the oil level is on the
extreme low level the LED may flash on and off quickly and the generator
will run unevenly. The yellow LED will illuminate when the generator is
being attempted to start if the oil is low, i.e. when the cord is being pulled,
the yellow LED will glow if there is insufficient oil. In this condition, the
generator will not start. In this condition you need to add oil for the
generator to operate.
2. Load Status indicator (Fig M)
The red load status indicator light (8) advises the operator that a fault
has been detected and the power supply to the control panel has been
interrupted. When the red load status indicator is operating red, there is NO
240Va.c. available to the control panel.
When the engine is running the load status indicator light (8) flashes under
the following conditions:
a. Flashing once indicates low voltage protection, caused by the engine
rotation speed not meeting the specified reqauirements.
b. Flashing twice indicates the engine is overheated, caused by high
temperature.
c. Flashing 3 times indicates overload protection caused by an excessive
electrical overload.
d. Flashing 4 times indicates there is an electrical problem most likely caused
by a short circuit.
In any of the above instances, when the red load status indicator light
(8) turns on, the power supply to the control panel will be disconnected
automatically.
NOTE:
The engine must be stopped and the issue resolved before the
power supply will be restored.