AE–1800 Instruction Manual
Customizing Operation via Menu System
4.12.4.2.
Selecting Parameters for RS–232C
Port (
continued – 2 / 2
)
If your RS–232C application requires a different set of parameters, select the
appropriate values by following the steps given below:
(1) Press
/
to highlight the desired parameter.
For example, to change the parity bit status to non–parity, highlight “
3:PARITY
.
”
(2) Press
/
to highlight the desired value, and then press
.
For example, highlight “
NONE
” and press
.
Figure 4-33 Changing Parity Bit Status Parameter – Example
(3) Press
to return to the previous submenu or
to return to the first receiver
text page.
4.12.4.3.
Selecting Parameters for RS–422
Port
The parameters for the
RS–422
port are initially set as follows:
Figure 4-34 Checking Current Parameters for RS–422
・
Data Bits: 8 bits
・
Stop Bits: 1 bit
・
Parity:
Odd parity
・
Bit Rate: 4800 baud
The current parameter values
can be checked by selecting
“
2:RS–422
” as shown at right.
Each parameter can be changed in the same manner as in the example given above
(paragraph 4.12.4.2). Be sure to press
after selecting the desired value.
(
continued on next page
)
1: RS–232C
1: DATA BITS
7
I
8
I
2: STOP BITS
I
1
I 2
3: PARITY
I ODD
I
NONE
I
4: BIT RATE
i
0.11
4.8
9.6 19.2 38.4
(1) Highlight this with
/
.
(2) Highlight this with
/
, and press
.
3: SET BIT FORMAT & RATE
1: RS– 232C
2: RS– 422
3: I / O DATA
2: RS–422
1: DATA BITS
I 7
I
8
I
2: STOP BITS I
1
I 2
3: PARITY
i
ODD
NONE
4: BIT RATE
0.11
4.8
9.6
19.2
38.4