OmniSwitch 6850/6850E Series Power Supplies
OmniSwitch 6850/6850E Series Power Supplies
page 4-20
OmniSwitch 6850/6850E Series Hardware Users Guide
June 2011
Viewing the Power Supply Status
The switch constantly monitors the power supply operation. If either the primary or backup power source
(optional) unexpectedly shuts down, the switch sends out a notification to the user. In addition, the power
LED on the chassis front panel display solid amber.
Note.
For detailed LED information, refer to
“Status LEDs” on page 2-54
.
To check the number of power supplies currently operating, and the status of each power supply, use the
show power
command. For example:
-> show power
Power Supplies in chassis 1
PS Operational Status
---------+-------------------
PS-1 UP
PS-2 NOT PRESENT
The primary (i.e., factory-installed) power supply is listed as
PS-1
in the
show power
command output.
The backup power supply is listed as
PS-2
. In the example above, there is no backup power supply