background image

OmniSwitch 6850E Series Chassis and Hardware Components

page 3-12

OmniSwitch 6850/6850E Series Hardware Users Guide

June 2011

OmniSwitch 6850E-P24X Rear Panel

OS6850E-P24X Rear Panel

Note . 

 The rear panel of the PoE models contain three DB-25 power supply connectors. One of the 

connectors is the for the primary power supply and two of the connectors are for the redundant power 
supplies.  The primary power supply must be connected to the primary connector. A redundant power 
supply can be connected to either of the redundant connectors. 

Item

Description

A

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply. 

B

Grounding Block

Type LCD8-10A-L grounding lug

C

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

D

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

E

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

C

A

B

D

E

Summary of Contents for OS6850-48

Page 1: ...Part No 060209 10 Rev K June 2011 OmniSwitch 6850 6850E Series Hardware Users Guide www alcatel lucent com...

Page 2: ...atel Lucent OmniVista are registered trademarks of Alcatel Lucent OmniAccess Omni Switch Router PolicyView RouterView SwitchManager VoiceView WebView X Cell X Vision and the Xylan logo are trademarks...

Page 3: ...al Support xv Chapter 1 OmniSwitch 6850 6850E Series 1 1 Availability Features 1 2 Software Rollback 1 2 Backup Power Supplies 1 2 Hot Swapping 1 3 Hardware Monitoring 1 3 Chapter 2 OmniSwitch 6850 Se...

Page 4: ...Power Cords 2 67 Specifications 2 67 Console Port 2 68 Serial Connection Default Settings 2 68 Modifying the Serial Connection Settings 2 68 Console Port Pinouts 2 70 10 100 Ethernet Port RJ 45 Pinout...

Page 5: ...t Port RJ 45 Pinout 3 34 10 100 1000 Mbps Power over Ethernet Port RJ 45 Pinout 3 34 RJ 45 Console Port Connector Pinout 3 35 Chapter 4 OmniSwitch 6850 6850E Series Power Supplies 4 1 OmniSwitch 6850...

Page 6: ...ity Disconnect is Enabled Incoming PD Port has Highest Priority Level 5 10 Priority Disconnect is Enabled Incoming PD Port has Lowest Priority Level 5 10 Priority Disconnect is Disabled 5 11 Monitorin...

Page 7: ...6 40 Appendix A Regulatory Compliance and Safety Information A 1 Declaration of Conformity CE Mark A 1 Waste Electrical and Electronic Equipment WEEE Statement A 1 China RoHS Hazardous Substance Tabl...

Page 8: ...er a de litio A 12 Advertencia sobre la tensi n de operaci n A 12 Advertencia sobre la desconexi n de la fuente A 12 Advertencia sobre una apropiada conexi n a tierra A 13 Leer informaci n importante...

Page 9: ...es your switch hardware components and basic switch hardware procedures Supported Platforms This information in this guide applies to the following products OmniSwitch 6850 24 24L P24 P24L 24X P24X Om...

Page 10: ...une 2011 Unsupported Platforms The information in this guide does not apply to the following products OmniSwitch original version with no numeric model name OmniSwitch 6600 Family OmniSwitch 6800 Seri...

Page 11: ...es backup power supplies etc in greater depth What is in this Manual This users guide includes the following hardware related information Descriptions of stand alone and stacked configurations Descrip...

Page 12: ...up a password and setting up stacks It also includes succinct overview information on fundamental aspects of the switch such as hardware LEDs the soft ware directory structure stacking CLI conventions...

Page 13: ...Configuration Guide contains overview information procedures and examples on how standard networking technologies are configured on the OmniSwitch The OmniSwitch AOS Release 6 Advanced Routing Config...

Page 14: ...ude the software directory architecture image rollback protections authenticated switch access managing switch files system configuration using SNMP and using web management software WebView OmniSwitc...

Page 15: ...excuses technical support You ll also receive regular software updates to maintain and maximize your Alcatel Lucent prod uct s features and functionality and on site hardware replacement through our...

Page 16: ...Technical Support About This Guide page xvi OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Page 17: ...rate layer 2 forwarding and layer 3 routing with advanced services effective availability resiliency and security features and are ideal for the following network applications Enterprise workgroups LA...

Page 18: ...o referred to as image rollback essentially allows the OmniSwitch to return to a prior last known good version of software in the event of a system software problem The switch controls software rollba...

Page 19: ...ds a trap to the user The trap is displayed on the console in the form of a text error message In the case of an over threshold temperature condition the chassis displays an amber TMP LED in addition...

Page 20: ...Availability Features OmniSwitch 6850 6850E Series page 1 4 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Page 21: ...0 P48L 48 port 10 100 Power over Ethernet PoE OmniSwitch 6850 U24X OS6850 U24X 24 port Gigabit SFP with 10 Gigabit uplinks OmniSwitch 6850 24 OS6850 24 24 port 10 100 1000 OmniSwitch 6850 48 OS6850 48...

Page 22: ...11 This chapter includes detailed information on these chassis types Topics include OmniSwitch 6850 Series chassis descriptions Technical specifications Switch mounting Booting OmniSwitch 6850 Series...

Page 23: ...figurable to be 10 100 1000Base T or 1000Base X high speed connections The front panel of the OS6850 24L chassis contains the following major components System status and slot indicator LEDs 20 unshar...

Page 24: ...nector provides a DTE console connection Status and Slot Indicator LEDs For information on the OS6850 24L s status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can be...

Page 25: ...10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Ope...

Page 26: ...witch 6850 24L OmniSwitch 6850 Series Chassis and Hardware Components page 2 6 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 Maximum cable distance RJ 45 100 meters OS6850 24L Specificat...

Page 27: ...nfigurable to 10 100 1000Base T or 1000Base X high speed connec tions The front panel of the OS6850 48L chassis contains the following major components System status and slot indicator LEDs 44 unshare...

Page 28: ...atus and Slot Indicator LEDs For detailed information on OS6850 48L status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can be used for quick upgrades Combo SFP The OS...

Page 29: ...pplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Operating Temperature 0 to 45 de...

Page 30: ...configurable to be 10 100 1000Base T PoE or 1000Base X high speed connections The front panel of the OS6850 P24L chassis contains the following major components System status and slot indicator LEDs 2...

Page 31: ...J 45 con nector provides a DTE console connection Status and Slot Indicator LEDs For information on the OS6850 P24L s status and slot indicator LEDs refer to page 2 53 USB Port High speed port which c...

Page 32: ...s Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative...

Page 33: ...page 2 13 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Page 34: ...y configurable to 10 100 1000Base T PoE or 1000Base X high speed connections The front panel of the OS6850 P48L chassis contains the following major components System status and slot indicator LEDs 44...

Page 35: ...nection Status and Slot Indicator LEDs For detailed information on OS6850 P48L s status and slot indica tor LEDs refer to page 2 53 USB Port High speed USB port which can be used for quick upgrades Co...

Page 36: ...Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative...

Page 37: ...page 2 17 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Page 38: ...ering 24 1000Base X SFP connectors two 2 10 Gigabit XFP connectors as well as four combo individually configurable to 10 100 1000Base T The front panel of the OS6850 U24X chassis contains the followin...

Page 39: ...provides two combo 10 100 1000BaseT By default when an SFP is installed in a combo port it takes over the port number of the corresponding RJ 45 Ethernet port In other words if an SFP is installed in...

Page 40: ...ssis Width rack mount flanges not included 17 5 inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed W...

Page 41: ...sers Guide June 2011 page 2 21 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 10...

Page 42: ...witch offering 20 unshared 10 100 1000 Base T as well as four combo individually configurable to be 10 100 1000 Base T or 1000 Base X high speed connections The front panel of the OS6850 24 chassis co...

Page 43: ...RJ 45 port for console connections Console connec tions are used by network admin istrators for switch management This female RJ 45 connector provides a DTE console connec tion Status and Slot Indica...

Page 44: ...epth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage...

Page 45: ...Switch 6850 Series Chassis and Hardware Components OmniSwitch 6850 24 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 2 25 Maximum cable distance RJ 45 100 meters OS6850 24 Specificat...

Page 46: ...p switch offering 44 unshared 10 100 1000Base T as well as four combo individually configurable to 10 100 1000Base T or 1000Base X high speed connec tions The front panel of the OS6850 48 chassis cont...

Page 47: ...us and Slot Indicator LEDs For detailed information on OS6850 48 status and slot indicator LEDs refer to page 2 53 OmniSwitch 6850 48 USB Console OK PRI PWR BPS CLASS 1 LASER PRODUCT 1 2 3 4 1 2 3 4 5...

Page 48: ...5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Operat...

Page 49: ...Switch 6850 Series Chassis and Hardware Components OmniSwitch 6850 48 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 2 29 Maximum cable distance RJ 45 100 meters OS6850 48 Specificat...

Page 50: ...1000 Base T Power over two 2 10 Gigabit XFP connectors as well as four combo individually configurable to 10 100 1000 Base T or 1000 Base X high speed connections The front panel of the OS6850 24X ch...

Page 51: ...s four combo SFP connectors for 1000Base X high speed connections By default when an SFP is installed in a combo port it takes over the port number of the corresponding RJ 45 Ethernet port In other wo...

Page 52: ...idth rack mount flanges not included 17 5 inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight...

Page 53: ...sers Guide June 2011 page 2 33 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 10...

Page 54: ...ch 6850 48X The OmniSwitch 6850 48X is a stackable edge workgroup switch offering 48 unshared 10 100 1000Base T and two 2 10 Gigabit XFP connectors The front panel of the OS6850 48X chassis contains t...

Page 55: ...t The front panel provides one RJ 45 port for console connections Console connections are used by network administrators for switch management This female RJ 45 connector provides a DTE console connec...

Page 56: ...dity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Operating Temperature 0 to 45 degrees Celsius Storage Temperature 20 to 70 degrees Celsius Altitude Operating altitude sea le...

Page 57: ...20 unshared 10 100 1000 Base T Power over Ethernet PoE as well as four combo individually configurable to 10 100 1000 Base T PoE or 1000 Base X high speed connections The front panel of the OS6850 P24...

Page 58: ...n nector provides a DTE console connection Status and Slot Indicator LEDs For information on the OS6850 P24 s status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can b...

Page 59: ...nches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Rela...

Page 60: ...June 2011 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Page 61: ...44 unshared 10 100 1000 Base T Power over Ethernet PoE as well as four combo individually configurable to 10 100 1000 Base T PoE or 1000 Base X high speed connections The front panel of the OS6850 P48...

Page 62: ...onnection Status and Slot Indicator LEDs For information on the OS6850 P48 s status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can be used for quick upgrades OmniSwi...

Page 63: ...inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Rel...

Page 64: ...June 2011 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Page 65: ...Power over Ethernet PoE two 2 10 Gigabit XFP connectors as well as four combo individu ally configurable to 10 100 1000 Base T PoE or 1000 Base X high speed connections The front panel of the OS6850...

Page 66: ...es two for 10 Gbps Small Form Factor Pluggable XFP transceiv ers OmniSwitch 6850 P24X USB Console OK PRI PWR BPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 26 25 CLASS 1 LASE...

Page 67: ...hassis Width rack mount flanges not included 17 5 inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed...

Page 68: ...ints Internet cameras and other devices requiring power over Ethernet Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded...

Page 69: ...e OmniSwitch 6850 P48X is a stackable edge workgroup switch offering 48 unshared 10 100 1000Base T Power over Ethernet PoE and two 2 10 Gigabit XFP connectors The front panel of the OS6850 P48X chassi...

Page 70: ...2 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 10 100 1000Mbps PoE The OS6850 P48X provides 48 fixed 10 100 1000BaseT non combo PoE 1 48 These are auto sensing and auto MDIX and use RJ 45 connector...

Page 71: ...Relative Humidity Storage Operating Temperature 0 to 45 degrees Celsius Storage Temperature 20 to 70 degrees Celsius Altitude Operating altitude sea level at 40 degrees Celsius and 10000 feet at 0 deg...

Page 72: ...h 6850 P48X OmniSwitch 6850 Series Chassis and Hardware Components page 2 52 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 Maximum cable distance RJ 45 RJ 45 100 meters OS6850 P48X Speci...

Page 73: ...7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Slot Indicator LED The slot indicator LED dis plays the switch s current slot...

Page 74: ...plays blinking green when transmitting or receiving packets in a link up state off when no link is detected It displays solid amber 10 100 Mbps for a valid link displays blinking amber when transmit t...

Page 75: ...n optional redundant power supply Two stacking A and B Grounding block for type LCD8 10A L grounding lug Note The figure shows a pre production version of the chassis without product safety and compli...

Page 76: ...ord s OmniSwitch 6850 Series Chassis Top View Note Never obstruct the air vents located at the sides of the chassis Obstructing these vents can cause switch failure Clearance is not required at the to...

Page 77: ...es Otherwise airflow may become restricted Restricted airflow can cause your switch to overheat overheating can lead to switch failure See Airflow Considerations on page 2 56 for more information on c...

Page 78: ...ive internal switch components from physical damage by closing off the chassis When blank cover panels are missing air does not take the direct route from the air intake vent through the chassis and t...

Page 79: ...sides of the switch For recommended clearances refer to page 2 56 Also be sure that you have placed the chassis within the reach of all the required AC power sources 3 If you are installing a single i...

Page 80: ...rack mounting hardware For more information contact your Alcatel Lucent representative Alcatel Lucent does not provide rack mount screws Use the screws supplied by the rack vendor To prevent a rack f...

Page 81: ...are secure Attaching the Switch to the Rack Note Be sure to install the screws in the bottom hole of each flange as shown before proceeding 7 Once the screws at the bottom of each flange are secure in...

Page 82: ...most switch and bottom most switch in the stack must be connected using a redundant stacking cable Refer to Chapter 6 Managing OmniSwitch 6850 6850E Series Stacks for more information on the redundan...

Page 83: ...iled information on cabling patterns Be sure that cable connector is completely inserted and fully seated in the chassis 3 Insert the other end of the stacking cable into the stacking port of the swit...

Page 84: ...to the bottom switch Connect the redundant cable now Refer to the diagram below for more information Redundant Connection Between Top and Bottom Switches 6 Once all stacking cable connectors are inser...

Page 85: ...ers from the states shown in the table above refer to page 2 53 for more infor mation Contact Alcatel Lucent Customer Support if the LED state persists For information on logging in and configuring yo...

Page 86: ...for more infor mation Contact Alcatel Lucent Customer Support if the LED state persists For information on logging in and configuring your OmniSwitch 6850 Series stack refer to the OmniSwitch 6850 Ser...

Page 87: ...es in an IEC 320 attachment plug and the other end terminates in a NEMA 5 15P plug The power cord to be used with 230 Volt configuration is minimum type SJT SVT 18 3 rated 250 Volts AC 10 Amps with a...

Page 88: ...ge will display For switches in a stacked configuration all changes must be configured before the switches are cabled together In other words you must configure these settings when each switch is oper...

Page 89: ...ile at the boot prompt Boot commit file When the commit file command is used changes will not be enabled until after the next switch reboot 8 You can also save your changes in real time to the switch...

Page 90: ...Ethernet Port RJ 45 Pinout non PoE Gigabit Ethernet Port RJ 45 Pinout 10 100 1000 Mbps Power over Ethernet Port RJ 45 Pinout Pin Number Description 1 RX 2 RX 3 TX 4 not used 5 not used 6 TX 7 not used...

Page 91: ...and Hardware Components Console Port OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 2 71 RJ 45 Console Port Connector Pinout Pin Number Signals as DTE Console Port 1 NC 2 NC 3 RXD 4...

Page 92: ...Console Port OmniSwitch 6850 Series Chassis and Hardware Components page 2 72 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Page 93: ...mniSwitch 6850E P24 on page 3 5 OmniSwitch 6850E 24X see OmniSwitch 6850E 24X on page 3 8 OmniSwitch 6850E P24X see OmniSwitch 6850E P24X on page 3 11 OmniSwitch 6850E 48 see OmniSwitch 6850E 48 on pa...

Page 94: ...rt C System Status LEDs Provides status on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbere...

Page 95: ...el Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector DB...

Page 96: ...50E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8 36 lbs 3...

Page 97: ...us on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbe...

Page 98: ...ary power supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 co...

Page 99: ...tack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Dept...

Page 100: ...0 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports are on bottom row E SFP Combo Ports and LEDs Comb...

Page 101: ...nel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector DB...

Page 102: ...50E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8 40 lbs 3...

Page 103: ...100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports are on bottom row E SFP Combo Ports and LEDs C...

Page 104: ...r supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 connector...

Page 105: ...stack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Dep...

Page 106: ...rt C System Status LEDs Provides status on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbere...

Page 107: ...ation labels All production versions of the chassis have these labels OS6850E 48 Rear Panel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 co...

Page 108: ...6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8...

Page 109: ...t C System Status LEDs Provides status on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numb...

Page 110: ...supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 connector f...

Page 111: ...Per stack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 R...

Page 112: ...dware software primary and redundant power D 10 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports are...

Page 113: ...anel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector D...

Page 114: ...6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8...

Page 115: ...are software primary and redundant power D 10 100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports a...

Page 116: ...r supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 connector...

Page 117: ...Per stack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 R...

Page 118: ...lement ID B USB Port High speed USB port C System Status LEDs Provides status on hardware software primary and redundant power D SFP Ports and LEDs Combo and non combo SFP connectors for various suppo...

Page 119: ...Panel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector...

Page 120: ...sh memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8 31 lbs 3 77 kg Relative Humidity Operating 5 to 9...

Page 121: ...ule Refer to OmniSwitch 6850E LED Status Indicators on page 3 31 for LED status information Refer to OmniSwitch 6850E Port Numbering on page 3 30 for port numbering To check the status of the uplink s...

Page 122: ...Switch 6850E Series switches OS6850E Port Numbering Table Non Combo Ports Combo Ports Non Combo SFP Ports Stacking Uplink Ports OS6850E 24 1 20 21 24 25 26 OS6850E P24 1 20 21 24 25 26 OS6850E 24X 1 2...

Page 123: ...tack Switch is idle not primary or secondary PWR Solid Green Solid Amber Off Primary power supply operational Primary power supply failure Primary power supply not present BPS Solid Green Solid Amber...

Page 124: ...message will display For switches in a stacked configuration all changes must be configured before the switches are cabled together In other words you must configure these settings when each switch is...

Page 125: ...file at the boot prompt Boot commit file When the commit file command is used changes will not be enabled until after the next switch reboot 8 You can also save your changes in real time to the switc...

Page 126: ...inout non PoE Gigabit Ethernet Port RJ 45 Pinout 10 100 1000 Mbps Power over Ethernet Port RJ 45 Pinout Pin Number Description 1 RX 2 RX 3 TX 4 not used 5 not used 6 TX 7 not used 8 not used Pin Numbe...

Page 127: ...and Hardware Components Console Port OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 3 35 RJ 45 Console Port Connector Pinout Pin Number Signals as DTE Console Port 1 NC 2 NC 3 RXD 4...

Page 128: ...Console Port OmniSwitch 6850E Series Chassis and Hardware Components page 3 36 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Page 129: ...Supplies OmniSwitch 6850 6850E Series switches various Power over Ethernet PoE and non PoE AC and DC Power supplies This chapter includes detailed information on these power supply types Topics includ...

Page 130: ...here is a power shelf provided with the unit that slides into the rear of the chassis and is used to hold the power supplies See the table below for valid configurations The power supplies can also be...

Page 131: ...2011 page 4 3 Power Supply Shelf Alcatel Lucent requires the use of power supply shelf when the power supply is used in a 1U i e 1 5 inches 3 8 cm configuration In a 2U i e 3 inches 7 6 cm configurat...

Page 132: ...lled as either a primary or redundant power supply 900W AC System PoE Power Supply P S Component Description Model PS 900AC P Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E 48...

Page 133: ...either a primary or redundant power supply 510W AC System PoE Power Supply P S Component Description Model PS 510W AC Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E PoE Models...

Page 134: ...either a primary or redundant power supply 510W AC Enhanced System PoE Power Supply P S Component Description Model PS 510W AC E Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850...

Page 135: ...her a primary or redundant power supply 360W AC System PoE Power Supply P S Component Description Model PS 360W AC Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E PoE Models In...

Page 136: ...ther a primary or redundant power supply 360W Enhanced AC System PoE Power Supply P S Component Description Model PS 360W AC E Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E P...

Page 137: ...wer Supply provides system power and can be installed as a redundant system power supply 126W AC System Power Supply P S Component Description Model PS 126W AC Provides Primary and Redundant System an...

Page 138: ...provides full system power and can be installed as a redundant system power supply 120W 48VDC System Power Supply P S Component Description Model PS 120W DC Provides Primary and Redundant System and...

Page 139: ...onal installation steps See DC Power Supply Considerations on page 4 16 for more information Anti Static Warning Before handling any components free yourself of static by wearing a grounding strap or...

Page 140: ...t a power supply shelf and connect the power supply with a cable Power Supply Shelf Rack Mounting Steps Follow the steps below to rack mount the power supply shelf 1 Align the threaded holes in the pr...

Page 141: ...y shelf 4 After the rack mount flanges and the power supply are secured to the shelf mark the holes on the rack where the shelf is to be installed 5 Lift and position the shelf until the rack mount fl...

Page 142: ...with a cable 1 Be sure the switch and power shelf are securely fastened to the rack 2 Connect the proper end of the supplied power supply cable to the appropriately labeled primary or backup connector...

Page 143: ...wer Supplies OmniSwitch 6850 6850E Series Power Supplies OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 4 15 Redundant Small Power Supplies i e 126W Redundant Large Power Supplies i...

Page 144: ...page 4 12 DC power supplies e g the PS 120W DC have the following additional considerations Connect to a 48V or 60V reliably grounded DC SELV source Use common DC return connections for the DC power...

Page 145: ...are Users Guide June 2011 page 4 17 Connecting a DC Power Source The DC power supply on your switch contains a power connector with three 3 square slots for connect ing the positive negative and groun...

Page 146: ...5 mm off the end of each wire removing the outer insulation to expose the copper core 2 Open the clamp for the ground wire slot by inserting a small flat tip screwdriver into the top of the appropria...

Page 147: ...ctor You should be able to pull on the wire and not dislodge it Warning For DC input voltages the positive wire of the sourcing equipment such as a battery or rectifier must be connected to the positi...

Page 148: ...user In addition the power LED on the chassis front panel display solid amber Note For detailed LED information refer to Status LEDs on page 2 54 To check the number of power supplies currently opera...

Page 149: ...ra tional status use the show chassis command For example show chassis Chassis 1 Model Name OS6850 48 Description 10 100 1000 Part Number 902274 10 Hardware Revision 005 Serial Number 439L0024 Manufac...

Page 150: ...nal Monitoring Commands CLI Commands Used for Monitoring a Chassis show cmm Displays the basic hardware and status information for primary and secondary management modules if applicable show ni Displa...

Page 151: ...e powering of attached devices via Ethernet For consistency this chapter and the CLI Command Reference Guide refer to the feature as Power over Ethernet PoE Additional terms such as Powered Device PD...

Page 152: ...CLI Reference Guide Topics and configuration procedures described in this chapter include Power over Ethernet Specifications on page 5 3 Viewing Power Status on page 5 4 Configuring Power over Ethern...

Page 153: ...oE administrative status Enabled Default PoE operational status Disabled PoE must be activated on a switch by switch basis via the lanpower start com mand Platforms supporting PoE OmniSwitch 6850 PoE...

Page 154: ...s of power supplies installed in the backup power supply use the show power command as shown below show power Slot PS Wattage Type Status Location 1 1 1 2 360 AC UP External 1 3 2 1 510 AC UP External...

Page 155: ...ustment based on the power class detected This will prevent the switch from delivering more than the maximum power allowed based on a device s class During class detection the switch will allocate the...

Page 156: ...e lanpower stop command To disable PoE on a specific PoE capable port enter a slot port number For example lanpower stop 8 22 To disable PoE for all PoE capable in a slot enter the corresponding slot...

Page 157: ...f power the slot can use to power all attached devices until the value is modified by the user Note Changing the maximum power available to a slot or port does not reserve or immediately allocate that...

Page 158: ...npower capacitor detection followed by the slot number of the switch and enable For example to enable the capacitor detection method on the switch with slot number 2 enter lanpower capacitor detection...

Page 159: ...y disconnect uses port priority and port number criteria for determining the power status of incom ing PDs refer to the illustrated examples on pages 5 10 through 5 11 Reminder Priority disconnect app...

Page 160: ...r off the system software first selects the port with the lowest configured priority level For exam ple if a critical priority device is being added to a slot in which five existing devices are attach...

Page 161: ...1 Priority Disconnect is Disabled Reminder Priority disconnect examples are applicable only when there is inadequate power remaining to power an incoming device When priority disconnect is disabled po...

Page 162: ...unt of power budget remaining for PoE modules Total amount of power remaining for additional switch functions When entering the show lanpower command you must include a valid slot number in the comman...

Page 163: ...to their working as individual stand alone switches an OmniSwitch can also be linked together to work as a single virtual chassis known as a stack With stacks users can easily expand their switching c...

Page 164: ...s within the stack on page 6 5 Stack cabling on page 6 18 Slot numbering on page 6 22 Hot Swapping modules in a stack on page 6 27 Reloading switches on page 6 29 Changing the secondary module to prim...

Page 165: ...t 1 saved mode OS6850E Changing OS6850E Daughter Module Mode The OmniSwitch daughter module can be set to either stacking or uplink mode The mode must be set according to the module installed and how...

Page 166: ...h 6850 6850E Series Hardware Users Guide June 2011 The following example shows how to change the mode to stacking using the interfaces mode command interfaces 1 25 mode stacking WED JUL 01 18 08 29 HS...

Page 167: ...Module CMM and management module refer to those switches operating in a stack either in the primary or secondary management roles Switches operating in an idle role are essentially acting as network i...

Page 168: ...A stack of four switches is operating normally The stack consists of a primary module secondary module and two elements operating in idle status The software on all elements in the stack is synchroni...

Page 169: ...stack consists of a primary module and a secondary module The software on both elements in the stack is synchronized The primary management module fails or is taken offline e g powered off or reboote...

Page 170: ...econfigured slot information has been cleared For more information on using the lowest MAC address to determine the primary switch in a stack refer to the diagram below Primary Management Module Selec...

Page 171: ...t is important that each element in a stack is assigned a unique slot number Do not assign duplicate slot numbers to elements in a stack Otherwise one or more switches will be forced into pass through...

Page 172: ...via stacking cables All switches are currently powered off The user powers on a single switch in the stack In this case the bottom most switch is powered on The user now powers on the remaining switch...

Page 173: ...ine the secondary management module refer to the diagram below Secondary Management Module Selection Using the Stacking Connection to the Primary Switch Note For information on dynamic slot numbering...

Page 174: ...pass through mode refer to page 6 14 Primary Slot 1 Slot 3 Slot 4 Secondary Slot 2 Assumes Slot 1 Assumes Slot 3 Assumes Slot 4 Assumes Slot 2 Saved Slot 1 Four switches are stacked all switches are c...

Page 175: ...ernet ports The primary management module is like an NI module with the added task of overall stack management the secondary management module is like an NI with the added responsibility of backing up...

Page 176: ...the rest of the stack will not be disrupted Any elements in the stack not operating in pass through mode continue to operate normally The most common reason for one or more switches to enter pass thro...

Page 177: ...B NI Role State Saved Link A Remote Remote Link B Remote Remote Slot State NI Port State NI Port 1 PRIMARY RUNNING 1 UP 1001 StackA UP 2 StackA 2 SECONDARY RUNNING 2 UP 1 StackB UP 1001 StackB 1001 PA...

Page 178: ...e and using the optional reload syntax in the command line reboot the module stack set slot 1001 saved slot 3 reload When the module comes up it assumes the new unique slot position in this case slot...

Page 179: ...StackA 1003 PASS THRU DUP SLOT 2 UP 1002 StackB UP 2 StackA 1002 PASS THRU DUP SLOT 2 UP 1 StackB UP 1003 StackA 1 PRIMARY RUNNING 1 UP 3 StackB UP 1002 StackA 3 IDLE RUNNING 3 UP 4 StackB UP 1 StackA...

Page 180: ...nded that the cabling pattern remains consistent across the stack In addi tion for a stack to have effective redundancy a redundant stacking cable must be installed between the upper most and bottom m...

Page 181: ...portant For a stacked configuration to have effective redundancy a redundant stacking cable must be installed between the upper most and bottom most switch in the chassis at all times A stack of eight...

Page 182: ...lowing a Stacking Link Failure Data enters slot 1 via a 10 100 1000 Ethernet port The data is passed to slot 2 over the stacking cable connection then exits slot 2 via one of its 10 100 1000 Ethernet...

Page 183: ...acking cable connection exists between the top most and bottom most switches in the stack use the show stack status command For example show stack status Redundant cable status present Tokens used 12...

Page 184: ...a unique slot number To view the current slot assignments for a stack use the show ni or show module commands The slot number is also displayed on the front panel of each switch by the LED located on...

Page 185: ...to the diagrams below for more information on dynamic slot numbering Note As the slot numbers are dynamically assigned boot slot cfg files are auto generated in the flash directory of each switch Whe...

Page 186: ...Numbering Example 2 Slot 5 Idle Slot 4 Idle Slot 3 Idle In this example the bottom switch is elected the primary management module for the stack It can be assumed that this switch has the low est MAC...

Page 187: ...y and secondary switches at either the top or the bottom of the stack For this example the primary and second ary roles will be assigned to the top of the stack This is accomplished by entering the fo...

Page 188: ...ack s flash directories use the stack clear slot command on all modules and then reboot the stack For example stack clear slot 1 stack clear slot 2 stack clear slot 3 stack clear slot 4 stack clear sl...

Page 189: ...econdary management module Also removing a switch from a stacked configuration can disrupt stack cabling at the rear of the stack When removing a module be sure that stacking link integrity including...

Page 190: ...tack s by following the steps below 1 Make sure all switches are running the same software version 2 Clear the saved slot information from all incoming modules This will ensure that they are each assi...

Page 191: ...ed For example reload primary Note A primary management module reload can also be scheduled for a later time or date For informa tion on scheduling a primary module reload as well as additional comman...

Page 192: ...ment module The slot 2 switch is the secondary The user reloads the stack s primary management module by issuing the reload primary command Any data flow on the primary switch s Ethernet is interrupte...

Page 193: ...ion on scheduling a secondary module reload as well as additional command details refer to the OmniSwitch CLI Reference Guide Reloading the Secondary Management Module In a Stack of Three or More In t...

Page 194: ...ment module The slot 2 switch is the secondary The user reloads the stack s secondary management module by issuing the reload secondary command Any data flow on the secondary switch s Ethernet is inte...

Page 195: ...1 is reloaded it resumes its previous idle role Although it has the lowest possible saved slot number it does not take over the primary management role In order for this switch to take over the primar...

Page 196: ...mary switch s last known good software is propagated to all switches the synchronization process helps ensure effective redundancy across the stack Effects of Saved Slot Number Information on the Relo...

Page 197: ...tches that do not have saved slot information The primary management role will be given to the switch with the lowest saved slot number The secondary management role will be given to the switch with t...

Page 198: ...top switch in the stack and the third from top switch in the stack are reloaded simultaneously a problem will occur The switch between the two non adjacent switches will become isolated and the virtu...

Page 199: ...the switches in the stack are synchronized Otherwise data flow and switch management functions may be interrupted due to incorrect or outdated software when a switch takes over the primary management...

Page 200: ...man agement module The slot 2 switch is the secondary A takeover is initiated by the user the primary management module is automatically reloaded Any data flow on the primary switch s Ethernet is int...

Page 201: ...times To determine whether a stack is in need of synchronization use the show running directory command For example show running configuration CONFIGURATION STATUS Running CMM PRIMARY CMM Mode DUAL CM...

Page 202: ...w chassis Displays basic configuration and status information for the switch chassis show cmm Displays basic hardware and status information for primary and secondary management modules operating in t...

Page 203: ...wesentlichen Anforderungen und sonstigen Bestimmungen der Richtlinien 2004 108 EG EMV Richtlinie 2006 95 EG Niederspannungsrichtlinie 91 263 EWG Telekommunikationsendeinrichtungen falls zutreffend 199...

Page 204: ...ubstance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard This table shows where these substances may be found in the supply cha...

Page 205: ...ina RoHS Hazardous Substance Table OmniSwitch 6850 6850E Hardware Users Guide June 2011 page A 3 Products are packaged using one or more of the following packaging materials Corrugated Cardboard Corru...

Page 206: ...UL 60950 1 2nd Edition 2007 03 27 CAN CSA C22 2 No 60950 1 07 2nd Edition 2007 03 EN 60950 1 2006 with Amendment II 2009 IEC 60950 1 2005 2nd Edition AS NZS TS 001 and 60950 2005 Australia UL AR Arge...

Page 207: ...equipment It is suggested that the user use only shielded and grounded cables to ensure compliance with FCC Rules If this equipment does cause interference to radio or television reception the user is...

Page 208: ...a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance...

Page 209: ...nt trois fonctions importantes ils vitent tout risque de choc lectrique l int rieur du ch ssis ils font barrage aux interf rences lectromagn tiques susceptibles d alt rer le fonctionnement des autres...

Page 210: ...ect il est recommand de ne pas regarder fixement l int rieur de ces ouvertures Installez les caches connecteurs pr vus cet effet Deutsch Die Laser strahlen an der Blenden ffnung unsichtbares Licht ab...

Page 211: ...ement Warning To avoid shock hazard The power cord must be connected to a properly wired and earth receptacle Any equipment to which this product will attached must also be connected to properly wired...

Page 212: ...Guide Deutsch Der Getting Started Guide welcher diese Anlage beiliegt enth lt wichtige Sicherheitsinformationen ber die sie sich beim Arbeiten mit den Hardwareeinheiten bewu t sein sollten Sie sollten...

Page 213: ...Weil elektrostatische Aufladung ESD Teile der Anlage besch digen k nnten m ssen sie sich selbst erden bevor sie mit der Hardware Installation beginnen Zu diesem Zweck stellt Alcatel Lucent ein Erdung...

Page 214: ...dvertencia de radiaci n l ser invisible Los lasers emiten radiaci n invisible de la apertura abierta cuando no se conecta ning n cable de fibra ptica Al quitar los cables no mire fijamente en las aber...

Page 215: ...e restrinja el acceso Una ubicaci n con acceso restringido es una donde est seguro y limitado el acceso al personal de servicio que tiene un clave especial u otros medios de la seguridad Advertencia d...

Page 216: ...Instrucciones de seguridad en espa ol Regulatory Compliance and Safety Information page A 14 OmniSwitch 6850 6850E Hardware Users Guide June 2011...

Page 217: ...k mounting 2 60 rear panel 2 55 3 3 3 6 3 9 3 12 3 15 3 18 3 21 3 24 3 27 tabletop 2 59 chassis types OS6850 24 2 22 OS6850 24L 2 3 OS6850 24X 2 30 OS6850 48 2 26 OS6850 48L 2 7 OS6850 48X 2 34 OS6850...

Page 218: ...iSwitch 6850 P48L OS6850 P48X see OmniSwitch 6850 P48X OS6850 U24X see OmniSwitch 6850 U24X P pass through modules 6 14 reloading 6 33 pinouts 2 70 3 34 PoE 5 1 defaults 5 5 monitoring 5 4 5 12 priori...

Page 219: ...keover command 6 37 technical specifications console port 2 68 2 71 3 32 3 35 OmniSwitch 6850 24 2 24 3 4 OmniSwitch 6850 24L 2 5 OmniSwitch 6850 24X 2 32 OmniSwitch 6850 48 2 28 3 16 OmniSwitch 6850...

Page 220: ...Index Index 4 OmniSwitch 6850 Series Hardware Users Guide June 2011...

Reviews: