8

Keylock

Keylock prevents accidental key
entries during scanning.

1. To lock the keypad, press 

until KEYLOCK appears.

2. To unlock the keypad, press

until KEYLOCK disappears.

Note:

See page 4 for function keys,

controls and indicators while reading
this guide.

Setting the Squelch

To set the squelch, you must be in the
manual mode. No signal should be
present when adjusting squelch.

1. Press 

until you do not

hear a signal.

2. Adjust 

VOLUME

to a comfortable

listening level.

3. Think of the Squelch Control as a

gate. Turn 

SQUELCH

fully counter-

clockwise. This raises the "Squelch-
Gate" so high that no signals can
get through.

Basic Operation

4. Turn 

SQUELCH

fully clockwise until

you hear a hiss. This lowers the
"Squelch-Gate" so that everything
gets through - noise, weak, medium
and strong signals.

5. Turn 

SQUELCH

back counter-

clockwise just until the hiss stops.
Now the "Squelch Gate" allows only
strong signals through.

 

 

 

 

 

 

 

 

 

Summary of Contents for AE 77 H

Page 1: ...Albrecht AE 77 H Programmable Hand Held Scanner Operating Guide...

Page 2: ......

Page 3: ...use of this scanning radio in a motor vehicle may be prohibited regulated or require a permit in certain states cities and or local jurisdictions Your local law enforcement officials should be able t...

Page 4: ...ys 1 2 7 10 8 11 12 6 5 3 13 4 13 9 Controls and Indicators 21 24 18 23 22 20 19 14 Antenna Connector 15 Phone Jack 16 Squelch Control 17 On Off Volume Control Included in Your Package Antenna Belt cl...

Page 5: ...Lockout 10 Lockout in Manual Mode 10 Locking a Channel While Scanning 11 Lockout Tips 11 Restore a Locked Out Channel 11 Restore All Locked out Channels 12 Priority Scan 12 Changing the Priority Chan...

Page 6: ...frequency coverage is not totally continuous from 66 MHz to 512 MHz Preprogrammed Band Search See last page annex for Frequency Bands Feature Highlights These are helpful guidelines when using your n...

Page 7: ...the polarity symbols inside the battery compartment Warning Do not mix alkaline batteries with Ni Cd batteries Be sure to install four batteries of the same type 3 Replace cover and press down until...

Page 8: ...nt when adjusting squelch 1 Press until you do not hear a signal 2 Adjust VOLUME to a comfortable listening level 3 Think of the Squelch Control as a gate Turn SQUELCH fully counter clockwise This rai...

Page 9: ...and go back to Step 3 Programming Tips Group similar frequencies into adjacent channels For example program Marine frequencies in channels 1 through 10 and public services into channels 11 through 20...

Page 10: ...nnel When the transmission ends scanning resumes automatically after two seconds Channel Lockout You can lockout any channel so it is not reviewed during normal scanning You can restore the channel to...

Page 11: ...nnel is no longer in the scanning sequence Lockout Tips To quickly lockout a series of channels start with the lowest number channel For example if you are locking out channels 4 7 8 12 and 15 start w...

Page 12: ...anner monitors the channel until the transmission ends then resumes normal scanning You can designate any of the 100 available channels as your priority channel Changing the Priority Channel You canno...

Page 13: ...ect the band you wish to search 3 Wait for about 2 seconds and the UBC105XLT will begin searching that Band Or press LIMIT again to begin 4 Press LIMIT at any time to stop the search on a frequency Pr...

Page 14: ...ess 2 Select a channel a Enter the channel number b Then press OR Enter the frequency 3 Press or to start seaching 4 Press LIMIT at any time to stop the search on a frequency Press LIMIT to resume sea...

Page 15: ...ssed last 4 Press LIMIT to resume searching BAND Channel Skip If a particular channel continues to interrupt search scanning it is possible to set your scanner to skip the frequency If your scanner st...

Page 16: ...s PROG again STEP STEP Storing Search Frequencies You can quickly store any frequency you find during search 4 Press MON CLR and number key to select the MONITOR MEMORY OR MON CLR repeatedly 5 Press t...

Page 17: ...the height or angle of the antenna Do not plug the scanner into an outlet controlled by a wall switch because long power interruptions may cause memory loss Cleaning Disconnect the power to the unit b...

Page 18: ...be in a remote area which could require an optional multi band antenna Check with your dealer or local electronics store Scan won t stop 1 Adjust squelch threshold refer to page 8 Setting the Squelch...

Page 19: ...using optional adapter or 4 AA alkaline or rechargeable nickel cadmium batteries Antenna Rubber antenna included External jacks Earphone jack DC Charge jack DC power jack Size 64 5 W x 42 5 D x 147 H...

Page 20: ...olgenden europ ischen Normen entspricht is in conformity to following European Standards EU Richtlinien EU directives 73 23 EEC LVD 89 336 EEC EMC and 99 5 EEC R TTE EN 301 489 1 EN 301 489 5 EN 301 4...

Page 21: ...s Factory Programmed Search Ranges Display MHz Application b1 84 0150 87 2550 Police Rescue and Fire Brigade Germany only b2 108 0000 137 9916 Air band b3 137 0000 143 9950 Weather satellites and mili...