13
and it twinkles. When the detected temperature is
≥40
°C: the temperature
data shows 40°C or the ambient temperature and it twinkles.
When the temperature sensor detects that the temperature is continuously
≥40
°C in 2 minutes, the machine will stop working and boot the over-heat
defensive function. The red defrost indicator lights up for 3 seconds and
twinkles for 2 seconds. There is no response when you press any button.
1
)
When the machine is in over-temperature defensive function, please
unplug the power cord and when it has relieved the defensive function, it
can be turned on.
2
)
When the machine is in low temperature or high temperature defensive
functions unplug the power cord. The machine has no power off memory
function.
(4 h) Temperature and humidity sensor fault detect function
.
When the connectors on the temperature and humidity sensor get loose,
off line or bad contacted, the showed ambient temperature is 0°C, and the
humidity is 0%RH. The continuously dehumidify icon twinkles and the
machine turns to continuously dehumidifying.
You can press setting buttons to set automatically dehumidify, continuously
dehumidify and blow, but the machine will not operate according to your
setting, it will turn to continuously dehumidify mode.
You can press Dry button to set dry mode. Also the speed function, swing
function and timer function can be set. This malfunction will not influence
the dehumidification.
When the temperature sensor on the evaporator copper pipe is open circuit,
short circuit or connectors become loose, the red defrost indicator