12
Remove the water tank
(4 f) Compressor stop/boot defensive function
When the machine operates, the machine turns into the compress
defensive function when any operation causes the machine stops working.
The compressor will stop to operate after 3 minutes, which is the
compressor can not reboot in 3 minutes, while other functions are normal.
When operating, the dehumidify function will boot after 3 minutes when
you remove water tank then install it or turn off then turn on the machine.
(4 g) Low temperature and high temperature defensive function
In case that the machine is damaged when it operates in abnormal
environment or when the air intake temperature and humidity sensor
detects that the ambient is
≤0
°or
≥40
°C, the machine stops working and
change into temperature defensive function. The buzzer will alarm 3 long
beeps and 2 short beeps. The temperature which shows in the display
twinkle and there will be no repose when you press any button.
When the detected temperature is
≤0
°C: the temperature data shows 0°C