(4 d) Automatic defrost function 

When the machine operates in low ambient temperature, the evaporator 

surface may be frozen. In order to make the machine operates normally, the 

machine is equipped with defrost function. 

1.

 

When the temperature sensor fixed on the evaporator copper pipe 
detects the temperature is 

-1°C: The machine will change to 

automatically defrost program, the machine will defrost automatically 
after it operates for 20minutes.   

2.

 

When the frost on the evaporator melt and the temperature sensor 
detects the ambient temperature is 

3°C and the melting time is longer 

than 5 minutes, the machine will stop defrosting and turn in to 
dehumidify function. 

3.

 

When defrosting, the red defrost indicator        lights up. 

4.

 

When defrosting, the compressor stops working, the fan speed is in 
middle grade (when the machine defrost in dry mode, fan operates in 
high speed and the fan icon does not show in the display). The 
dehumidify function will be turned up after defrosting, and the fan will 
turn back into the former setting grade. 

   

(4 e) Water full defensive function 

When the machine operates and the water in the water tank rises to the 

setting level, 10 beeps alarm and the red water full indicator (FULL) lights up. 

The machine stops working and the air plate will turn off. Remove the water 

tank, pour out the water and then install the water tank. The machine will 

operate in the former settings, the red water full indicator turns off (the 

dehumidify function will reboot when the time between the water full and 

install the water tank is longer than 3 minutes). 

Summary of Contents for ARCTUS FENJA 25

Page 1: ...1 A AR RC CT TU US S F FE EN NJ JA A 2 25 5 User Manual...

Page 2: ...lay c Operating instruction d Automatic defrost function e Water full defensive function f Compressor stop boot defensive function g Low temperature and high temperature defensive function h Temperatu...

Page 3: ...be caused in high temperature condition Neither place it in the sun in case that the color of casing fades or discolors 4 Please do not use it in the place which exists much dust corrosive gas or flam...

Page 4: ...shock 11 Please do not unplug the power cord when your hand is wet in case of electric shock 12 Please turn off the machine before unplug the power cord in case of electric shock or other dangers 13...

Page 5: ...t or similarly qualified persons in order to avoid a hazard 2 Operating Condition 1 Lowest working condition Temperature 5 relative humidity 40 RH Highest working condition Temperature 35 relative hum...

Page 6: ...6 3 Name of components Front and top Rear Control Panel Air deflector Water Tank Handle Air intake Continuous drain pipe...

Page 7: ...function 4 Speed button SPEED Press this button to choose middle grade or low grade working condition 5 Swing button SWING Turn on or turn off the air outlet swing function 6 Timer button TIMER Press...

Page 8: ...machine operates press ON OFF the machine stops operating and the air plate will turn off automatically 3 Dehumidify button DEHUMIDIFY Press dehumidify button can set automatically dehumidifying cont...

Page 9: ...the display shows Dry icon and the machine operates in Dry mode The dehumidifier s operate is out of ambient humidity control and operates in continuously dehumidifying state The air plate swings aut...

Page 10: ...sition in the swing range The swing icon shows in the display in swing mode 7 Timer button TIMER Press this button can set Power on off time a Timer to turn on the machine When the machine is power of...

Page 11: ...osting the red defrost indicator lights up 4 When defrosting the compressor stops working the fan speed is in middle grade when the machine defrost in dry mode fan operates in high speed and the fan i...

Page 12: ...en you remove water tank then install it or turn off then turn on the machine 4 g Low temperature and high temperature defensive function In case that the machine is damaged when it operates in abnorm...

Page 13: ...wer cord The machine has no power off memory function 4 h Temperature and humidity sensor fault detect function When the connectors on the temperature and humidity sensor get loose off line or bad con...

Page 14: ...t will remain the former operate mode If there is a power failure unplug the power cord or the power outage when the machine operates the machine will reboot automatically and operate in continuously...

Page 15: ...e remove and place the water tank gently When cleaning the casing please use clean and soft cloth please do not use alcohol gasoline benzene or other chemical solvent Keep the filter clean Please plac...

Page 16: ...long time Please pack it up when the machine becomes dry and please keep it in dry environment in order to lengthen its life Please place the machine straight do not make it up side down When doing m...

Page 17: ...ity water tank 5 L Size 372 282 614 mm This product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled w...

Reviews: