11
(4 d) Automatic defrost function
When the machine operates in low ambient temperature, the evaporator
surface may be frozen. In order to make the machine operates normally, the
machine is equipped with defrost function.
1.
When the temperature sensor fixed on the evaporator copper pipe
detects the temperature is
≤
-1°C: The machine will change to
automatically defrost program, the machine will defrost automatically
after it operates for 20minutes.
2.
When the frost on the evaporator melt and the temperature sensor
detects the ambient temperature is
≥
3°C and the melting time is longer
than 5 minutes, the machine will stop defrosting and turn in to
dehumidify function.
3.
When defrosting, the red defrost indicator lights up.
4.
When defrosting, the compressor stops working, the fan speed is in
middle grade (when the machine defrost in dry mode, fan operates in
high speed and the fan icon does not show in the display). The
dehumidify function will be turned up after defrosting, and the fan will
turn back into the former setting grade.
(4 e) Water full defensive function
When the machine operates and the water in the water tank rises to the
setting level, 10 beeps alarm and the red water full indicator (FULL) lights up.
The machine stops working and the air plate will turn off. Remove the water
tank, pour out the water and then install the water tank. The machine will
operate in the former settings, the red water full indicator turns off (the
dehumidify function will reboot when the time between the water full and
install the water tank is longer than 3 minutes).