12
- Coin selector setup
Among the accepted coins (0.05-to-2 $), the following ones get enabled by default: 1.00 $ - 2.00 $.
To modify this condition, press OK to get to the first option (ex. 2 $) and highlight it, then press UP
or DOWN to reverse its state
. Press OK to shift to the next option (ex. 1 $).
- Dispensing Mode setup
Allows to choose whether to dispense C
OINS
or T
OKENS
or T
OKENS
+C
HANGE
, and whether the
DISPENSING MODE
will be
AUTOMATIC
or
MANUAL
.
It also permits to monitor the level of the coins in the hopper(s) by the electronic sensors.
NOTICE: monitoring of level sensors is disabled by default. This means that the board does not know when the hopper
is empty, so it will send the pay-out command even if there are no coins available.
If instead the monitoring has been enabled, and there are not enough coins in the hoppers, the display will warn that
the hoppers is empty. There are yet contained 20 coins approximately, to be able to complete the change payout.
PAY ATTENTION!: when re-programming from token to coins, always do RESTORE DEFAULT
CONFIGURATION and ACCOUNTS RESET, or else bonuses given will false the Accounts records.
7.3.7 E
MPTY OUT
H
OPPERS
Use this function to make the selected hopper pay out all the contained coins / tokens.
When depletion hase been completed, the paid out value will be displayed.
Set up
Coin acceptor
< 2,00 > 1,00 0,50
OK OK OK
< 2,00 > 1,00 0,50
NO
OK OK
2,00 < 1,00 > 0,50
OK OK OK
2,00 1,00 < 0,50 >
OK
NO
OK
SET UP
DISPENSING MODE
Set up
COINS
Level sensors
enabled
Level sensors
disabled
Set up
TOKENS
Set up Hopper 1:
1,00 $
(*) Use keys Down and Up to
modify values
(*)
Set up Hopper 2:
0,50 $
(*)
Set up
CHANGE
Dispense mode
AUTOMATIC
Dispense mode
MANUAL
(**) NOTICE:
1.
DO NOT USE TOKENS IN
HopperCD!
2.
Option TOKEN+CHANGE
only if two
Hoppers
are in
circuit. DO NOT USE
TOKENS IN HopperCD!
(**)
(**)
EMPTY OUT
HOPPER
Empty out
Hopper 1
Deplete Hopper 1
Total nn,nn $
Empty out
Hopper 2
Deplete Hopper 2
Totale nn,nn $
Exit