Bluetooth 2D Imager Barcode Scanner
Configuration Guide
MK-5800BT
Page 1: ...Bluetooth 2D Imager Barcode Scanner Configuration Guide MK 5800BT ...
Page 2: ...d the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RF exposure warning This equipment must be installed and operated in accordance with ...
Page 3: ...ode Required EAN 13 Beginning with 414 419 Add On Code Required EAN 13 Beginning with 434 439 Add On Code Required EAN 13 Beginning with 977 Add On Code Required EAN 13 Beginning with 978 Add On Code Required EAN 13 Beginning with 979 Add On Code Required Code 32 Italian Pharma Code Code 32 Prefix Transmit Code 32 Check Digit and Transmit Code 32 Start Stop Character features in Chapter 8 Note Fir...
Page 4: ...odes Same Barcode 5 Sense Mode 6 Decode Session Timeout 6 Image Stabilization Timeout 7 Timeout between Decodes 7 Continue after Good Read 7 Timeout between Decodes Same Barcode 8 Sensitivity 9 Continuous Mode 10 Decode Session Timeout 10 Timeout between Decodes 10 Timeout between Decodes Same Barcode 11 Chapter 3 Scanning Preferences 12 Introduction 12 Decode Area 12 Whole Area Decoding 12 Specif...
Page 5: ...t NGR Message 21 Chapter 6 Prefix Suffix 22 Global Settings 23 Enable Disable All Prefix Suffix 23 Prefix Sequences 23 Custom Prefix 24 Enable Disable Custom Prefix 24 Set Custom Prefix 24 AIM ID Prefix 25 Code ID Prefix 25 Restore All Default Code IDs 25 Modify Code ID 26 Custom Suffix 29 Enable Disable Custom Suffix 29 Set Custom Suffix 29 Terminating Character Suffix 30 Enable Disable Terminati...
Page 6: ...re Factory Defaults 36 Enable Disable AIM 128 36 Set Length Range for AIM 128 36 EAN 8 37 Restore Factory Defaults 37 Enable Disable EAN 8 37 Transmit Check Digit 38 Add On Code 38 Add On Code Required 39 EAN 8 Extension 39 EAN 13 40 Restore Factory Defaults 40 Enable Disable EAN 13 40 Transmit Check Digit 40 Add On Code 41 Add On Code Required 41 EAN 13 Beginning with 290 Add On Code Required 42 ...
Page 7: ... Add On Code 49 Add On Code Required 49 UPC E 50 Restore Factory Defaults 50 Enable Disable UPC E 50 Transmit Check Digit 50 Add On Code 51 Add On Code Required 51 Transmit System Character 0 51 UPC E Extension 52 UPC A 53 Restore Factory Defaults 53 Enable Disable UPC A 53 Transmit Check Digit 53 Add On Code 54 Add On Code Required 54 Transmit Preamble Character 55 Interleaved 2 of 5 56 Restore F...
Page 8: ...lts 64 Enable Disable Standard 25 64 Set Length Range for Standard 25 64 Check Digit Verification 65 Code 39 66 Restore Factory Defaults 66 Enable Disable Code 39 66 Transmit Start Stop Character 66 Set Length Range for Code 39 67 Check Digit Verification 67 Enable Disable Code 39 Full ASCII 67 Enable Disable Code 32 68 Code 32 Prefix 68 Transmit Code 32 Check Digit 69 Transmit Code 32 Start Stop ...
Page 9: ...1 76 Set Length Range for Code 11 76 Transmit Check Digit 77 Check Digit Verification 77 Plessey 78 Restore Factory Defaults 78 Enable Disable Plessey 78 Set Length Range for Plessey 78 Check Digit Verification 79 MSI Plessey 80 Restore Factory Defaults 80 Enable Disable MSI Plessey 80 Set Length Range for MSI Plessey 80 Transmit Check Digit 81 Check Digit Verification 81 2D Symbologies 82 PDF 417...
Page 10: ...rcode 87 Mirror Image 87 Data Matrix Twin Code 88 Character Encoding 88 Chinese Sensible Code 89 Restore Factory Defaults 89 Enable Disable Chinese Sensible Code 89 Set Length Range for Chinese Sensible Code 89 Chapter 8 Image Control 90 Image Flipping 90 Flip 91 Flip Vertically 91 Flip Horizontally 91 Chapter 9 Batch Programming 92 Introduction 92 Create a Batch Command 93 Create a Batch Barcode ...
Page 11: ...Program the Decoding Area 108 h Program the Custom Prefix Suffix 108 i Program the Terminating Character Suffix 109 j Program the Code ID 109 k Program the NGR Message 109 l Program the Length Range Maximum Minimum Lengths for a Symbology 110 m Program the Code Page 110 n Program the Custom Inter keystroke Delay 111 o Program the engine to get proper output for Russian encoded with Windows 1251 11...
Page 12: ... your engine To exit the setup mode scan the Exit Setup barcode If the scanner has exited the setup mode only some special programming barcodes such as the Enter Setup barcode and Restore All Factory Defaults barcode can be read Enter Setup Exit Setup Factory Defaults Scanning the following barcode can restore the scanner to the factory defaults Note Use this feature with discretion Restore All Fa...
Page 13: ...s no longer present Rereading the same barcode is not allowed if it was decoded previously in the same round For good read the engine transmits decoded data via communication port To activate another round of multiple scans the Host needs to first negate the trigger waits 20ms or longer and then drive the TRIG pin low Batch Mode ...
Page 14: ...ivate another session the Host needs to first negate the trigger waits 20ms or longer and then drive the TRIG pin low Trigger Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt It is programmable in 1ms increments from 100ms to 3 600 000ms When it is set to 0 the timeout is infinite The default setting is 3 000ms To learn how to program ...
Page 15: ...igger Mode to automatically enter the sleep or low power mode if no operation or communication is performed for a time period user programmable When the scanner is in the sleep mode receiving trigger signal can awake the scanner The scanner returns to full operation within 100ms The parameter below specifies how long the scanner remains idle no operation or communication occurs before it is put in...
Page 16: ...w the engine to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Same Barcode Allow the engine to re read same barcode The following parameter sets the timeout between decodes for same barcode It is programmable in 1ms increments from 0ms to 65 535ms The default setting is 1 500ms To learn how to program this parameter see Appendix 4 Time...
Page 17: ...nger present or the barcode is decoded or the decode session timeout expires The trigger signal needs to be negated before the scanner is able to monitor ambient illumination again Sense Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt If the timeout expires or the barcode is decoded the engine goes back to monitoring ambient illuminat...
Page 18: ...ut between decode sessions When a decode session ends next session will not happen until the timeout between decodes expires It is programmable in 1ms increments from 0ms to 65 535ms The default setting is 1 000ms To learn how to program this parameter see Appendix 4 Timeout between Decodes Continue after Good Read Continue after Good Read The scanner starts next decode session after good read Pau...
Page 19: ... the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Same Barcode Allow the scanner to re read same barcode Disable Timeout between Decodes Same Barcode Enable Timeout between Decodes Same Barcode The following parameter sets the timeout between decodes for same barcode It is programmable in 1ms increments from 0ms to 65 535ms...
Page 20: ...ironment Medium Sensitivity Low Sensitivity High Sensitivity Enhanced Sensitivity If the above four options fail to meet your needs you may program the threshold value of illumination change Illumination changes that reach or surpass the predefined threshold value will cause the scanner to start a decode session The lower the threshold value the greater the sensitivity of the engine The default th...
Page 21: ...arcode reading Continuous Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt It is programmable in 1ms increments from 100ms to 3 600 000ms When it is set to 0 the timeout is infinite The default setting is 3 000ms To learn how to program this parameter see Appendix 4 Decode Session Timeout Timeout between Decodes This parameter sets the...
Page 22: ...w the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Same Barcode Allow the scanner to re read same barcode Disable Timeout between Decodes Same Barcode Enable Timeout between Decodes Same Barcode The following parameter sets the timeout between decodes for same barcode It is programmable in 1ms increments from 0ms to 65 535m...
Page 23: ... its field of view from the center to the periphery and transmits the barcode that has been first decoded Whole Area Decoding Specific Area Decoding The scanner attempts to read barcode s within a specified decoding area and transmits the barcode that has been first decoded This option allows the scanner to narrow its field of view to make sure it reads only those barcodes intended by the user For...
Page 24: ...e white box is the decoding area Since Barcode 1 passes through the decoding area it will be read Barcode 2 does not pass through the decoding area so it will not be read You can define the decoding area using the Top of Decoding Area Bottom of Decoding Area Left of Decoding Area and Right of Decoding Area barcodes as well as numeric barcode s that represent s a desired percentage 0 100 To learn h...
Page 25: ...Enter Setup Exit Setup 14 Top of Decoding Area Bottom of Decoding Area Left of Decoding Area Right of Decoding Area ...
Page 26: ...lumination options are provided to improve the lighting conditions during every image capture Normal Illumination LEDs are turned on during image capture Always ON Illumination LEDs keep ON after the engine is powered on OFF Illumination LEDs are OFF all the time Normal OFF Always ON ...
Page 27: ...allows positioning the target barcode within its field of view and thus makes decoding easier Normal The scnner projects an aiming pattern only during barcode scanning capture Always ON Aiming pattern is constantly ON after the scanner is powered on OFF Aiming pattern is OFF all the time Normal OFF Always ON ...
Page 28: ...Enter Setup 17 Exit Setup Chapter 5 Beep LED Notifications Startup Beep If startup beep is enabled the scanner will beep after being turned on Enable Startup Beep Disable Startup Beep ...
Page 29: ...cuit to drive a beeper after decoding a non programming barcode Scan the appropriate barcode below to enable or disable the emission of good read beep Beep type frequency and volume are also user programmable Good Read Beep On for Non programming Barcode Good Read Beep Off for Non programming Barcode Beep Type Type 1 Type 3 Type 2 ...
Page 30: ...haracters contained in barcode data may be unavailable on the selected keyboard USB HID KBW As a result the scanner fails to transmit the unknown characters Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected Beep on Unknown Character Do Not Beep on Unknown Character ...
Page 31: ...Enter Setup Exit Setup 20 Good Read Beep for Programming Barcode Good Read Beep On for Programming Barcode Good Read Beep Off for Programming Barcode ...
Page 32: ...barcode is not decoded Transmit NGR Message Do Not Transmit NGR Message Edit NGR Message To edit an NGR message scan the Edit NGR Message barcode and the numeric barcodes corresponding to the ASCII values hex of desired characters and then scan the Save barcode An NGR message can contain 0 7 characters ASCII value of character 0x00 0xFF Edit NGR Message ...
Page 33: ...cter suffix like Carriage Return or Line Feed can also be the alternatives Data formatting may include Append AIM ID Code ID custom prefix before the decoded data Append custom suffix after the decoded data Append terminating character to the end of the data The following formats can be used when editing barcode data Code ID Custom Prefix AIM ID DATA Custom Suffix Terminating Character Custom Pref...
Page 34: ... data with no prefix suffix Enable All Prefix Suffix Allow user to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission Enable All Prefix Suffix Disable All Prefix Suffix Prefix Sequences Code ID Custom Prefix AIM ID Custom Prefix Code ID AIM ID ...
Page 35: ...e numeric barcodes representing the hexadecimal values of a desired prefix and then scan the Save barcode Refer to Appendix 3 ASCII Table for hexadecimal values of characters Note A custom prefix cannot exceed 11 characters Set Custom Prefix Example Set the custom prefix to CODE 1 Check the hex values of CODE in the ASCII Table CODE 43 4F 44 45 2 Scan the Enter Setup barcode 3 Scan the Set Custom ...
Page 36: ...ine will add the symbology identifier before the scanned data after decoding Enable AIM ID Prefix Disable AIM ID Prefix Code ID Prefix Code ID can also be used to identify barcode type Unlike AIM ID Code ID is user programmable Code ID can only consist of one or two English letters Enable Code ID Prefix Disable Code ID Prefix Restore All Default Code IDs For the information of default Code IDs see...
Page 37: ... ID of PDF417 to p 1 Check the hex value of p in the ASCII Table p 70 2 Scan the Enter Setup barcode 3 Scan the Modify PDF417 Code ID barcode 4 Scan the numeric barcodes 7 and 0 5 Scan the Save barcode 6 Scan the Exit Setup barcode Modify PDF417 Code ID Modify Data Matrix Code ID Modify QR Code ID Modify Chinese Sensible Code ID Modify Code 128 Code ID Modify GS1 128 Code ID ...
Page 38: ...dify AIM 128 Code ID Modify EAN 8 Code ID Modify EAN 13 Code ID Modify UPC E Code ID Modify UPC A Code ID Modify ISBN Code ID Modify ISSN Code ID Modify Code 39 Code ID 7 8 Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID ...
Page 39: ... Modify ITF 6 Code ID Modify Codabar Code ID Modify Industrial 25 Code ID Modify Standard 25 Code ID Modify Matrix 25 Code ID Modify COOP 25 Code ID Modify Code 11 Code ID Modify Plessey Code ID Modify MSI Plessey Code ID Modify GS1 Databar Code ID ...
Page 40: ...e numeric barcodes representing the hexadecimal values of a desired suffix and then scan the Save barcode Refer to Appendix 3 ASCII Table for hexadecimal values of characters Note A custom suffix cannot exceed 11 characters Set Custom Suffix Example Set the custom suffix to CODE 1 Check the hex values of CODE in the ASCII Table CODE 43 4F 44 45 2 Scan the Enter Setup barcode 3 Scan the Set Custom ...
Page 41: ... of data which means nothing can be added after it A terminating character suffix cannot exceed 7 characters Enable Disable Terminating Character Suffix To enable disable terminating character suffix scan the appropriate barcode below Enable Terminating Character Suffix Disable Terminating Character Suffix ...
Page 42: ...Character Suffix barcode and the numeric barcodes representing the hexadecimal value of a desired terminating character and then scan the Save barcode Refer to Appendix 3 ASCII Table for hexadecimal values of terminating characters Note A terminating character suffix cannot exceed 7 characters Set Terminating Character Suffix Example Set the terminating character suffix to 0x0D 1 Scan the Enter Se...
Page 43: ... programming barcodes Enable All Symbologies Disable All Symbologies Enable Disable 1D Symbologies If the Disable 1D Symbologies feature is enabled the scanner will not be able to read any 1D barcodes Enable 1D Symbologies Disable 1D Symbologies Enable Disable 2D Symbologies If the Disable 2D Symbologies feature is enabled the scanner will not be able to read any 2D barcodes Enable 2D Symbologies ...
Page 44: ...e examples of regular barcode and inverse barcode are shown below Regular Barcode Inverse Barcode Video Reverse is used to allow the scanner to read barcodes that are inverted Video Reverse ON Read both regular barcodes and inverse barcodes Video Reverse OFF Read regular barcodes only The engine shows a slight decrease in scanning speed when Video Reverse is ON Video Reverse ON Video Reverse OFF ...
Page 45: ...34 1D Symbologies Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 Set Length Range for Code 128 Set the Minimum Length Set the Maximum Length ...
Page 46: ... Setup GS1 128 UCC EAN 128 Restore Factory Defaults Restore the Factory Defaults of GS1 128 Enable Disable GS1 128 Enable GS1 128 Disable GS1 128 Set Length Range for GS1 128 Set the Minimum Length Set the Maximum Length ...
Page 47: ...xit Setup 36 AIM 128 Restore Factory Defaults Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 Enable AIM 128 Disable AIM 128 Set Length Range for AIM 128 Set the Minimum Length Set the Maximum Length ...
Page 48: ...Enter Setup 37 Exit Setup EAN 8 Restore Factory Defaults Restore the Factory Defaults of EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 ...
Page 49: ...by blue dotted line is an EAN 8 barcode while the part circled by red dotted line is add on code Enable 2 Digit Add On Code Disable 2 Digit Add On Code Enable 5 Digit Add On Code Disable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of EAN 8 barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add O...
Page 50: ... EAN 8 barcodes that contain add on codes EAN 8 Add On Code Required EAN 8 Add On Code Not Required EAN 8 Extension Disable EAN 8 Zero Extend Transmit EAN 8 barcodes as is Enable EAN 8 Zero Extend Add five leading zeros to decoded EAN 8 barcodes to extend to13 digits Enable EAN 8 Zero Extend Disable EAN 8 Zero Extend ...
Page 51: ...t Setup 40 EAN 13 Restore Factory Defaults Restore the Factory Defaults of EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit Do Not Transmit EAN 13 Check Digit ...
Page 52: ...he scanner decodes a mix of EAN 13 barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code when presented with an EAN 13 plus add on barcode It can also decode EAN 13 barcodes without add on codes Add On Code Required When EAN 13 Add On Code Required is selected the scanner will only read ...
Page 53: ... on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 378 379 Add On Code Required This setting programs the scanner to require an add on code 2 digit or 5 digit on EAN 13 barcodes that begin with a 378 or 379 The following settings can be programmed Require Add On Code All EAN 13 barcodes that begin with a 378 or 379 must have...
Page 54: ...d depending on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 434 439 Add On Code Required This setting programs the scanner to require an add on code 2 digit or 5 digit on EAN 13 barcodes that begin with a 434 or 439 The following settings can be programmed Require Add On Code All EAN 13 barcodes that begin with a 434 or 43...
Page 55: ...d depending on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 978 Add On Code Required This setting programs the scanner to require an add on code 2 digit or 5 digit on EAN 13 barcodes that begin with 978 The following settings can be programmed Require Add On Code All EAN 13 barcodes that begin with 978 must have a 2 digit ...
Page 56: ... that begin with 979 must have a 2 digit or 5 digit add on code The EAN 13 barcode with the add on code is then transmitted If the required add on code is not found the EAN 13 barcode is discarded Do Not Require Add On Code If you have selected Require Add On Code and you want to disable this feature scan Do Not Require Add On Code EAN 13 barcodes are handled depending on your selection for the Ad...
Page 57: ...Enter Setup Exit Setup 46 ISSN Restore Factory Defaults Restore the Factory Defaults of ISSN Enable Disable ISSN Enable ISSN Disable ISSN ...
Page 58: ... Code The scanner decodes a mix of ISSN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISSN and ignores the add on code when presented with an ISSN plus add on barcode It can also decode ISSN barcodes without add on codes Add On Code Required When ISSN Add On Code Required is selected the scanner will only read ISS...
Page 59: ...Enter Setup Exit Setup 48 ISBN Restore Factory Default Restore the Factory Defaults of ISBN Enable Disable ISBN Enable ISBN Disable ISBN Set ISBN Format ISBN 13 ISBN 10 ...
Page 60: ... Code The scanner decodes a mix of ISBN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISBN and ignores the add on code when presented with an ISBN plus add on barcode It can also decode ISBN barcodes without add on codes Add On Code Required When ISBN Add On Code Required is selected the scanner will only read ISB...
Page 61: ... Exit Setup 50 UPC E Restore Factory Defaults Restore the Factory Defaults of UPC E Enable Disable UPC E Enable UPC E Disable UPC E Transmit Check Digit Transmit UPC E Check Digit Do Not Transmit UPC E Check Digit ...
Page 62: ...e The scanner decodes a mix of UPC E barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC E and ignores the add on code when presented with a UPC E plus add on barcode It can also decode UPC E barcodes without add on codes Add On Code Required When UPC E Add On Code Required is selected the scanner will only read UPC...
Page 63: ...rcode is the system character 0 Transmit System Character 0 Do Not Transmit System Character 0 UPC E Extension Disable UPC E Extend Transmit UPC E barcodes as is Enable UPC E Extend Extend UPC E barcodes to make them compatible in length to UPC A Enable UPC E Extend Disable UPC E Extend ...
Page 64: ... 53 Exit Setup UPC A Restore Factory Defaults Restore the Factory Defaults of UPC A Enable Disable UPC A Enable UPC A Disable UPC A Transmit Check Digit Transmit UPC A Check Digit Do Not Transmit UPC A Check Digit ...
Page 65: ...e The scanner decodes a mix of UPC A barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC A and ignores the add on code when presented with a UPC A plus add on barcode It can also decode UPC A barcodes without add on codes Add On Code Required When UPC A Add On Code Required is selected the scanner will only read UPC...
Page 66: ... and System Character can be transmitted as part of a UPC A barcode Select one of the following options for transmitting UPC A preamble to the host device transmit system character only or transmit system character and country code 0 for USA System Character Country Code System Character ...
Page 67: ...estore Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set Length Range for Interleaved 2 of 5 Set the Minimum Length Set the Maximum Length ...
Page 68: ...r Verification The scanner checks the integrity of all Interleaved 2 of 5 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification Note If the Do Not Transmit Check Digit After Verification opt...
Page 69: ...ength of 14 characters and the last character as the check character Restore the Factory Defaults of ITF 14 Disable ITF 14 Enable ITF 14 But Do Not Transmit Check Digit Enable ITF 14 and Transmit Check Digit Note It is advisable not to enable ITF 14 and Interleaved 2 of 5 at the same time ...
Page 70: ... length of 6 characters and the last character as the check character Restore the Factory Defaults of ITF 6 Disable ITF 6 Enable ITF 6 But Do Not Transmit Check Digit Enable ITF 6 and Transmit Check Digit Note It is advisable not to enable ITF 6 and Interleaved 2 of 5 at the same time ...
Page 71: ...x 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Set Length Range for Matrix 2 of 5 Set the Minimum Length Set the Maximum Length ...
Page 72: ...Enter Setup 61 Exit Setup Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification ...
Page 73: ... Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Industrial 2 of 5 Disable Industrial 2 of 5 Set Length Range for Industrial 2 of 5 Set the Minimum Length Set the Maximum Length ...
Page 74: ...Enter Setup 63 Exit Setup Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification ...
Page 75: ...d 2 of 5 IATA 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Standard 25 Enable Disable Standard 25 Enable Standard 25 Disable Standard 25 Set Length Range for Standard 25 Set the Minimum Length Set the Maximum Length ...
Page 76: ...Enter Setup 65 Exit Setup Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification ...
Page 77: ...6 Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do Not Transmit Start Stop Character ...
Page 78: ...k Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification Enable Disable Code 39 Full ASCII The engine can be configured to identify all ASCII characters by scanning the appropriate barcode below Enable Code 39 Full ASCII Disable Code 39 Full ASCII ...
Page 79: ...able Code 32 Code 39 must be enabled and Code 39 check digit verification must be disabled for this parameter to function Disable Code 32 Enable Code 32 Code 32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character A to all Code 32 barcodes Code 32 must be enabled for this parameter to function Disable Code 32 Prefix Enable Code 32 Prefix ...
Page 80: ...bled for this parameter to function Do Not Transmit Code 32 Check Digit Transmit Code 32 Check Digit Transmit Code 32 Start Stop Character Code 32 must be enabled for this parameter to function Do Not Transmit Code 32 Start Stop Character Transmit Code 32 Start Stop Character ...
Page 81: ...xit Setup 70 Codabar Restore Factory Defaults Restore the Factory Defaults of Codabar Enable Disable Codabar Enable Codabar Disable Codabar Set Length Range for Codabar Set the Minimum Length Set the Maximum Length ...
Page 82: ...Setup Check Digit Verification Disable Transmit Check Digit After Verification Do Not Transmit Check Digit After Verification Transmit Start Stop Character Transmit Start Stop Character Do not Transmit Start Stop Character ...
Page 83: ...Format You can choose your desired start stop character format by scanning the appropriate barcode below ABCD ABCD as the Start Stop Character ABCD TN E as the Start Stop Character Start Stop Character in Uppercase Start Stop Character in Lowercase ...
Page 84: ...3 Exit Setup Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable Disable Code 93 Enable Code 93 Disable Code 93 Set Length Range for Code 93 Set the Minimum Length Set the Maximum Length ...
Page 85: ...Enter Setup Exit Setup 74 Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification ...
Page 86: ...estore Factory Defaults Restore the Factory Defaults of GS1 Databar Enable Disable GS1 Databar Enable GS1 DataBar Disable GS1 DataBar Transmit Application Identifier 01 Transmit Application Identifier 01 Do Not Transmit Application Identifier 01 ...
Page 87: ...xit Setup 76 Code 11 Restore Factory Defaults Restore the Factory Defaults of Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Set Length Range for Code 11 Set the Minimum Length Set the Maximum Length ...
Page 88: ... Do Not Transmit Check Digit Check Digit Verification Disable One Check Digit MOD11 Two Check Digits MOD11 MOD11 Two Check Digits MOD11 MOD9 One Check Digit MOD11 Len 10 Two Check Digits MOD11 MOD11 Len 10 One Check Digit MOD11 Len 10 Two Check Digits MOD11 MOD9 Len 10 ...
Page 89: ...xit Setup 78 Plessey Restore Factory Defaults Restore the Factory Defaults of Plessey Enable Disable Plessey Enable Plessey Disable Plessey Set Length Range for Plessey Set the Minimum Length Set the Maximum Length ...
Page 90: ...Enter Setup 79 Exit Setup Check Digit Verification Disable Do Not Transmit Check Digit After Verification Transmit Check Digit After Verification ...
Page 91: ... MSI Plessey Restore Factory Defaults Restore the Factory Defaults of MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Set Length Range for MSI Plessey Set the Minimum Length Set the Maximum Length ...
Page 92: ...er Setup 81 Exit Setup Transmit Check Digit Transmit Check Digit Do Not Transmit Check Digit Check Digit Verification Disable One Check Digit MOD10 Two Check Digits MOD10 MOD10 Two Check Digits MOD10 MOD11 ...
Page 93: ...up 82 2D Symbologies PDF 417 Restore Factory Defaults Restore the Factory Defaults of PDF 417 Enable Disable PDF 417 Enable PDF 417 Disable PDF 417 Set Length Range for PDF 417 Set the Minimum Length Set the Maximum Length ...
Page 94: ...pecifications and be placed closely together There are 3 options for reading PDF417 twin codes Single PDF417 Only Read either PDF417 code Twin PDF417 Only Read both PDF417 codes Both Single Twin Read both PDF417 codes If successful transmit as twin PDF417 only Otherwise try single PDF417 only Single PDF417 Only Twin PDF417 Only Both Single Twin Character Encoding Default Character Encoding UTF 8 ...
Page 95: ...Restore Factory Defaults Restore the Factory Defaults of QR Code Enable Disable QR Code Enable QR Code Disable QR Code Set Length Range for QR Code Set the Minimum Length Set the Maximum Length Micro QR Enable Micro QR Disable Micro QR ...
Page 96: ...have similar specifications and be placed closely together There are 3 options for reading QR twin codes Single QR Only Read either QR code Twin QR Only Read both QR codes Both Single Twin Read both QR codes If successful transmit as twin QR only Otherwise try single QR only Single QR Only Twin QR Only Both Single Twin Character Encoding Default Character Encoding UTF 8 ...
Page 97: ... Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable Disable Data Matrix Enable Data Matrix Disable Data Matrix Set Length Range for Data Matrix Set the Minimum Length Set the Maximum Length ...
Page 98: ...Enter Setup 87 Exit Setup Rectangular Barcode Enable Rectangular Barcode Disable Rectangular Barcode Mirror Image Decode Mirror Images Do Not Decode Mirror Images ...
Page 99: ...a Matrix twin codes Single Data Matrix Only Read either Data Matrix code Twin Data Matrix Only Read both Data Matrix codes Transmission order Data Matrix code on the left in the upper position followed by the one on the right in the lower position Both Single Twin Read both Data Matrix codes If successful transmit as twin Data Matrix only Otherwise try single Data Matrix only Single Data Matrix On...
Page 100: ... Factory Defaults Restore the Factory Defaults of Chinese Sensible Code Enable Disable Chinese Sensible Code Enable Chinese Sensible Code Disable Chinese Sensible Code Set Length Range for Chinese Sensible Code Set the Minimum Length Set the Maximum Length ...
Page 101: ... Fig 9 2 Horizontal Flipped Image It happens when horizontal reflection occurs along the optical path To get standard images enable the Flip Horizontally option Fig 9 3 Vertical Flipped Image It happens when vertical reflection occurs along the optical path To get standard images enable the Flip Vertically option Fig 9 4 Horizontal and Vertical Flipped Image It happens when the engine is installed...
Page 102: ...91 Exit Setup Flip Do Not Flip Flip Vertically Flip Horizontally Flip Horizontally and Vertically Flip Vertically Flip Vertically Do Not Flip Vertically Flip Horizontally Flip Horizontally Do Not Flip Horizontally ...
Page 103: ...ote that there is no space between a command and its terminator semicolon 3 Use the barcode generator software to generate a 2D batch barcode Example Create a batch barcode for Illumination Always On 0200010 Sense Mode 0302010 Decode Session Timeout 0313000 2s 1 Input the commands 0200010 0302010 0313000 2000 2 Generate a batch barcode When setting up an engine with the above configuration scan th...
Page 104: ...ch as the Maximum Minimum Length Decode Session Timeout Timeout between Decodes Same Barcode and Sensitivity Example Set the Decode Session Timeout to 3000ms 0313000 3000 Set the Sensitivity to level 10 0312040 10 3 Syntax 3 Command Hexadecimal Digit s e g 0x101A 0x2C03 This syntax applies to the features options programming like the Custom Prefix Suffix Terminating Character Suffix Code ID Suffix...
Page 105: ...barcodes can be produced in the format of PDF417 QR Code or Data Matrix Example Create a batch barcode for Illumination Always On Sense Mode Decode Session Timeout 2s 1 Input the following commands 0200010 0302010 0313000 2000 2 Generate a QR batch barcode ...
Page 106: ...Enter Setup 95 Exit Setup Use Batch Barcode To put a batch barcode into use scan the following barcodes Use the example above Enter Setup Enable Batch Barcode Batch Barcode Exit Setup ...
Page 107: ...ution 1 If this problem happens to all barcodes and additional characters appear before after barcode data disable all prefix suffix 2 If this problem only happens to some barcodes and matches one of the following situations a incomplete barcode data Enable the check digit verification b both the first and last characters are asterisks Disable the transmission of start stop characters of Code 39 c...
Page 108: ... that the engine is properly powered up 2 Send to the engine If the engine returns a reply of then send programming commands to turn on illumination and aimer Problem Carriage Return Line Feed settings Solution See the Terminating Character Suffix section in Chapter 7 ...
Page 109: ...haracter ISBT 128 C4 Interleaved 2 of 5 I0 No check digit verification I1 Transmit check digit after verification I3 Do not transmit check digit after verification ITF 6 I1 Transmit check digit I3 Do not transmit check digit ITF 14 I1 Transmit check digit I3 Do not transmit check digit Industrial 2 of 5 S0 Not specified Standard 2 of 5 R0 No check digit verification R8 MOD10 do not transmit check ...
Page 110: ...99 A7 Full ASCII enabled do not transmit check digit Codabar F0 Standard Codabar F2 Transmit check digit after verification F4 Do not transmit check digit after verification ...
Page 111: ...0 ECC140 d1 ECC200 d2 ECC200 FNC1 is the 1st or 5th character after the start character d3 ECC200 FNC1 is the 2nd or 6th character after the start character d4 ECC200 ECI included d5 ECC200 FNC1 is the 1st or 5th character after the start character ECI included d6 ECC200 FNC1 is the 2nd or 6th character after the start character ECI included QR Code Q0 QR1 Q1 2005 version ECI excluded Q2 2005 vers...
Page 112: ...IM 128 f EAN 8 d EAN 13 d ISSN n ISBN B UPC E c UPC A c Interleaved 2 of 5 e ITF 6 e ITF 14 e Matrix 2 of 5 v Industrial 2 of 5 D Standard 2 of 5 s Code 39 b Codabar a Code 93 i Code 11 H Plessey p MSI Plessey m GS1 Databar R PDF417 r QR Code Q Data Matrix u Chinese Sensible Code h ...
Page 113: ...Feed 0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgment 16 22 SYN Synchronous Idle 17 23 ETB End of Trans Block 18 24 CAN Cancel 19 25 EM End of Medium 1a 26 SUB Substitu...
Page 114: ...ollar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Left Opening Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign ...
Page 115: ...65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket ...
Page 116: ...00 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete ...
Page 117: ... Idle to Sleep Example Set the time period from idle to sleep to 500ms 1 Scan the Enter Setup barcode 2 Scan the Time Period from Idle to Sleep barcode See the Auto Sleep section in Chapter 3 3 Scan the numeric barcodes 5 0 and 0 4 Scan the Save barcode 5 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step c Program the Image Stabilization Timeout Exampl...
Page 118: ...he threshold value of illumination change to 4 1 Scan the Enter Setup barcode 2 Scan the Threshold Value of Illumination Change barcode See the Sensitivity section in Chapter 3 3 Scan the numeric barcode 4 4 Scan the Save barcode 5 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step f Program the Timeout between Decodes Example Set the timeout between de...
Page 119: ...ing Area barcode 10 Scan the numeric barcodes 2 and 0 11 Scan the Save barcode 12 Scan the Right of Decoding Area barcode 13 Scan the numeric barcodes 8 and 0 14 Scan the Save barcode 15 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step h Program the Custom Prefix Suffix Example Set the custom prefix to CODE 1 Check the hex values of CODE in the ASCII ...
Page 120: ... ASCII Table p 70 2 Scan the Enter Setup barcode 3 Scan the Modify PDF417 Code ID barcode See the Modify Code ID section in Chapter 6 4 Scan the numeric barcodes 7 and 0 5 Scan the Save barcode 6 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step k Program the NGR Message Example Set the NGR message to ERR 1 Check the hex values of ERR in the ASCII Tabl...
Page 121: ...the Set Length Range for Code 128 section in Chapter 7 3 Scan the numeric barcode 8 4 Scan the Save barcode 5 Scan the Set the Maximum Length barcode See the Set Length Range for Code 128 section in Chapter 7 6 Scan the numeric barcodes 1 and 2 7 Scan the Save barcode 8 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step m Program the Code Page Example S...
Page 122: ...ding barcode according to the symbology your application needs from the Character Encoding section in Chapter 8 6 Scan the Mode 3 barcode from the Emulate ALT Keypad section in Chapter 2 7 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step p Program the engine to get proper output for Russian encoded with UTF 8 1 Scan the Enter Setup barcode 2 Scan the ...
Page 123: ...112 Appendix 5 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9 ...
Page 124: ...113 A F A B C D E F ...
Page 125: ...ast Digit barcode and then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you scan Delete the Last Digit The last digit 3 will be removed Delete All Digits All digits 123 will be removed Cancel The maximum length configuration will be cancelled And the engine is still in the s...
Page 126: ...J VT Vertical Tab 0B Vertical Tab Ctrl K FF Form Feed 0C Delete Ctrl L CR Carriage Return 0D Enter Ctrl M SO Shift Out 0E Insert Ctrl N SI Shift In 0F Esc Ctrl O DLE Data Link Escape 10 F11 Ctrl P DC1 XON Device Control 1 11 Home Ctrl Q DC2 Device Control 2 12 Print Screen Ctrl R DC3 XOFF Device Control 3 13 Backspace Ctrl S DC4 Device Control 4 14 tab shift Ctrl T NAK Negative Acknowledgment 15 F...
Page 127: ...B 1C 1D 1E 1F United States Ctrl Ctrl Ctrl Ctrl 6 Ctrl Belgium Ctrl Ctrl Ctrl Ctrl 6 Ctrl Scandinavia Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl France Ctrl Ctrl 8 Ctrl Ctrl 6 Ctrl Germany Ctrl à Ctrl Ctrl 6 Ctrl Italy Ctrl Ctrl Ctrl 6 Ctrl Switzerland Ctrl Ctrl Ctrl 6 Ctrl United Kingdom Ctrl Ctrl Ctrl Ctrl 6 Ctrl Denmark Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl Norway Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl Spain Ctrl Ctrl Ct...
Page 128: ...117 Appendix 8 Code Pages List Numeric Barcode Needed Code Page 0 Windows 1252 Latin I 1 Windows 1251 Cyrillic ...