Alasking AH-500R Installation & Operation Manual Download Page 15

- 12 -

1.

Mode:

It can do Heat (MED) and Ventilation (Lo) functions by the receiver when the remote controller 

is abnormality.

Operation

功能

Function

用 途

Application

運轉狀態

Operation of each component

加熱器

Heater

預設時間

Time Pre-Set Up

啟動中溫暖房/低速換氣

Start Heat(MED)/Ventilation (LO)

設定遙控器頻率

Setting the frequency of the remote controller

功能全部停止/濾網計時賦歸

Stop all the functions/Re-timing about the filter

馬達

Motor

運轉

Operation

0.5小時

0.5 hour

2小時

2 hours

1100(W)

低速運轉

Operation(LO)

Function

1. 功能:

如遙控器發生異常時,可由接收器”功能”執行中溫暖房及低速換氣。

(6)

 

接收器使用說明:

2. 對頻:

更換遙控器或接收器時,須重新校正頻率。

按        3秒,黃、綠燈同時閃爍1秒閃1次 ,等待遙控器裝上電池後(       

 

與        同時按

下)回饋對頻訊號後,接收器重新自動對頻,對頻完成後長”嗶”聲約1秒。1分鐘內對頻不
完成恢復待機狀態。

OPERATE

對頻

功能

MODE

功能

MODE

啟動:按壓        一次為中溫暖房啟動,狀態指示燈紅燈亮起;再按壓        一次為低速換氣功能
         啟動,狀態指示燈綠燈亮起。

停止:按壓        或運轉所設時間到後,紅色指示燈或綠色指示燈會熄滅,本機自動停止。

停止

OFF

當熱功能運轉停止後,扇葉仍會運轉約20秒,以對加熱器進行冷卻。

(1) Start Press         button once to start the function of Heat (MED), and the status light shows 

with the red. If you need to change to the Ventilation (Lo) function, and then press

button again, and the status light will show with green.

功能

MODE

(2) Stop To stop midway in running, press        button. This product will stop automatically when 

the set time is up. The Red and Green indicator light go out and then the product will 

stop automatically. 

停止

OFF

(3) After operation stops , the fan operates for about 20 seconds. For cooling the heater .

Receiver

 

Instruction :

Summary of Contents for AH-500R

Page 1: ...AH 500R Model Please read the operation manual before use Read and retain this for future reference manual Thermo Ventilator Installation Operation Manual...

Page 2: ......

Page 3: ...Main Parts Installation Outline Installation Safety Instructions Electrical Distribution Instruction Remote Controller Instruction Receiver Maintenance and Safety Guide Breakdown Repair Specification...

Page 4: ...1 Name of Main Parts Main Body RF Wireless Remote Control Timer OFF Button Control Button Controller holder Main Body Cover Unit Dust Filter Receiver Outlet Adapter...

Page 5: ...295 Adapter Tapping screw 4x20 1pcs Corrugated Board Please follow the indicator of the arrowhead for making the mark 7 A A 1 Make a supportive frame Use strengthened frame to support the whole weigh...

Page 6: ...Main Body Install the mainbody to the suspenders The user needs to purchase suspenders separately and the suspender should use M8 only M8 M8 Suspenders Nut Suspension Bracket 1 2 3 2 4 20 4 A A 3 Inst...

Page 7: ...dy slot To ensure that snap fit is fixed with the body slot until hearing the Ca sound Please close the cover unit indeed Dust Filter Cover Unit Main Body Snap Fit Body Slot Cover Unit 2 Install the C...

Page 8: ...two plastic plugs then fix by two 4x20 screws Attach the wireless remote controller to the controller holder 0 5 1 2 3 4 6 8 TIME hr OFF 24 Hr VE NT HI VE NT LO VE NT CO OLDR Y HI HEA T MID HE AT HO T...

Page 9: ...vent or use shutter for circulation and air change Don t make transformation to this product Don t install the product as the method which is not approved in the instruction 10 Do not install onto sla...

Page 10: ...ugh to install the product Ensure that the appliance is switched off from the supply mains before removing the guard Electrical Distribution Overbend With too many bends on pipe The exhaust bend pipe...

Page 11: ...hours 24 24 hours 0 5 0 5 hour 0 5 0 5 hour 1700 W 1700 W 1200 W Operate Operate HI Operate LO Operate LO Operate Operate Wire Connection Way 1 To unload the electric case 2 Strip the cover of wire f...

Page 12: ...and also be used for drying the bathroom and clothes Operation 1 Start Press button to start the cool drying mode for operation and the green indicator blinks 3 green and yellow indicators go out and...

Page 13: ...uct will stop automatically when the set time is up The green and yellow indicators go out and then the product will stop automatically This product shows the remaining time by yellow indicator and me...

Page 14: ...urrent operating function and the indicator light of remainder will show the surplus time Press button to start the heat mode for operation and the red indicator blinks 2 3 4 After operation stops the...

Page 15: ...O Function 1 6 2 3 1 1 1 1 OPERATE MODE MODE OFF 20 1 Start Press button once to start the function of Heat MED and the status light shows with the red If you need to change to the Ventilation Lo func...

Page 16: ...cleaned 3 3 1000 OFF OFF 2 2 Remote When you change the remote controller or the receiver and then it has to do frequent pairs again Operation 1 Press for 3 seconds and the yellow indicator light and...

Page 17: ...ter neutral detergent and rinse with clean water To wipe cover unit when install it Please wipe it with cloth and neutral detergent can t leave detergent in the cover unit Clean the Dust Filter Please...

Page 18: ...ng 24 hours Vent 24 m h Air Volume Ventilation m h Air Volume Circulation 8 9 Phenomena Check Method Fan can t running when the power is on Receiver doesn t blink Remote doesn t blink Ask registered e...

Page 19: ...d in order to avoid danger 3 Porduct specification may subject to change without prior notice 4 Sheng Yuan has right to revise the contents of instruction manual without advice Controller Plastic plug...

Page 20: ...imited 469 471 13 Address 13 F Sunbeam Commercial Building 469 471 Nathan Road Kowloon HK Tel 852 2300 1210 Website www hklpg com hk 469 471 12 Address 12 F Sunbeam Commercial Building 469 471 Nathan...