17
USERS (Continued)
; 6 :
6. Enable Total User Lockout Mode
(This Function enabled through keypad only)
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
; 7 :
User Lockout Mode
Prevents all User Codes (Except User 1 Code) from operating the lock.
Note:
No other programming
functions or schedules will re-enable Users. Users must be re-enabled with Function 7.
Note:
Does not change the User enable/disable status.
Note:
If the lock is currently in Passage Mode
(door "unlocked") and Function 6 is programmed, the lock will remain in Passage Mode.
M
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
; 5 ;
[ _ _ _ _ ]
;
[ _ _ _ _ ]
:
(User Number) (XXX Hours)
•
With Function 5, User Numbers must be between 2-2000, hours must be between 1-999.
•
Function 5 can
temporarily
override a disabled User (disabled using Function 3 above).
•
Since this is a temporary feature, Function 5 can only be enabled using the keypad.
•
Example:
Brian, User Number 1157, rarely works at the office, but when he does, enable him for his 8 hour work day by entering
Program Mode and pressing:
;
5
;
1157
;
008
:
.
•
NOTE:
Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more
than 4 Timeout Functions.
2
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again.
NOTE:
User Number 297 is used to reset Service Code Use. See "Terminology Used in
this Manual" on page 7 for more information and examples regarding special Users 297-300.
; 9 :
9. Enable User 300
(Service Code)
2
2
; 1 0 ; 0 0 0 :
10. Erase All Users Except the Master Code
(User 1)
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
•
Function 10 can only be performed using the keypad.
M
11. Reserved
3. Disable User
; 3 ;
[ _ _ _ _ ]
:
(User Number)
4. Enable User
; 4 ;
[ _ _ _ _ ]
:
(User Number)
User Enable/Disable
(By User Number)
•
User Number must be between 2 and 2000.
NOTE:
Will Enable/Disable Users even if the User is associated with an enabled Group. Use Feature 3 to disable a specific User
Number and their associated User Code. If the disabled User Code is entered, the lock will flash 1 Green and 4 Red Flashes
(with 1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3.
2
8. Reserved
Programming Functions (cont'd)