16
1. New Master Code
(User Number 1)
2. Add/Delete/Change User Codes 2-2000
; 1 ;
[ _ _ _ _ _ _ ]
;
[ _ _ _ _ _ _ ]
:
(New Master Code) (Confirm New Master Code)
; 2 ;
[ _ _ _ _ ]
*
;
[ _ _ _ _ _ _ ]
:
(User Number) (User Code)
•
User Number must be between 2 and 2000.
•
To delete a code/card, leave the User Code blank and wait for the rapid beeping to stop, then
to avoid erroneously enrolling Proximity Cards, press and hold
:
for three seconds to exit
Programming Mode. If more programming is desired, re-enter Programming Mode.
•
User Code must be 3-6 digits.
•
Each User Code can be thought of as a person. As long as each person possesses their own
unique User Code, you can control access to the lock by adding or deleting User Codes. See
"Terminology Used in this Manual" on page 6 for more information.
•
Master Code must be 6 digits-only.
•
Master Code is Keypad Code Access only.
•
Factory Default =
123456
•
See "Lock Design Overview" on page 5 for more information about Master Codes.
3
M
USERS
Lock Defaults for
PDL3000/3500 & ETPDL
See page 8. Users added
will default to a Group Association and a Program Level Ability as follows:
USER TYPE
USER NUMBER
GROUP DEFAULT
ASSOCIATION
MINIMUM PROGRAM
LEVEL (see page 6)
Master
1
-
M
(All Programming Abilities)
Installers
2 & 3
none
4
(Also 3, 2, 1)
Managers
4 - 6
none
3
(Also 2, 1)
Supervisors
7 - 9
none
2
(Also 1)
Print Only Users
10 - 11
none
1
Basic Users
12 - 50
none
none
Basic Users in Group 1
51 - 100
1
none
Basic Users in Group 2
101 - 150
2
none
Basic Users in Group 3
151 - 200
3
none
Basic Users in Group 4
201 - 250
4
none
Basic Users
251 - 296
none
none
Quick Enable User 300
297
none
none
Quick PC Access
298
none
none
AL-DTM2 Code
299
none
none
Service User
300
none
none
Basic Users
301-2000
none
none
Programming Functions
User 299 is a Non-Pass Code. This is the only code that will initiate data transfer with the AL-DTM.