background image

15 

Function 1 

Change Master Code 

See page 16 

Function 2 

Add/Delete/Change User Codes 

See page 16 

Function 3 

User Disable (By User Number) 

See page 17 

Function 4 

User Enable (By User Number) 

See page 17 

Function 5 

User Enable with Timeout  

See page 17 

Function 6 

Enable Total User Lockout 

See page 17 

Function 7 

Disable Total User Lockout 

See page 17 

Function 8 

Reserved 

-- 

Function 9 

Enable User 300 (Service Code) 

See page 17 

Function 10 

Erase All Users Except the 
Master Code 

See page 17 

Function 11 

Reserved 

-- 

Function 12 

Clear All Schedules and Timeout 
Functions 

See page 18 

Function 13 

Clear All Timeout Functions 

See page 18 

Function 14 - 17 

Group 1-4 Disable 

See page 18 

Function 18 

Disable All Groups 

See page 18 

Function 19 - 22 

Group 1-4 Enable 

See page 18 

Function 23 

Enable All Groups 

See page 18 

Function 24 

Reserved 

-- 

Function 25 - 28 

Group Disable with Timeout 

See page 19 

Function 29 

Disable All Groups with Timeout 

See page 19 

Function 30 - 33 

Group Enable with Timeout 

See page 19 

Function 34 

Disable All Groups with Timeout 

See page 19 

Function 35 

Group Add/Delete Association 

See page 19 

Function 36 - 37 

Reserved 

-- 

Function 38 

Set Date 

See page 20 

Function 39 

Set Time 

See page 20 

Function 40 

Set Weekday 

See page 20 

Function 41 

Daylight Saving Time Start Date 

See page 20 

Function 42 

Daylight Saving Time End Date 

See page 20 

Function 43 

Speed Up Clock 

See page 21 

Function 44 

Slow Down Clock 

See page 21 

Function 45 - 46 

Passage Mode Enable/Disable 

See page 21 

Function 47 

Timed Passage Mode 

See page 21 

Programming Functions--Overview 

Function 48 

Enable Passage Mode  

See page 22 

Function 49 

Disable Passage Mode 

See page 22 

Function 50 

Return Lock to Normal Passage 
Mode Schedule 

See page 22 

Function 51 

Passage Mode Configuration  

See page 22 

Function 52 - 54 

Pass Time 

See page 22 

Function 55 

Print Audit Trail  

See page 23 

Function 56 

Print User Code List  

See page 23 

Function 57 

Print Clock Settings and Software 
Version  

See page 23 

Function 58 

Upload/Download PC Data 

See page 23 

Function 59 

AL-DTM2 Door Number 

See page 24 

Function 60 

Number of Attempt Before 
Lockout  

See page 24 

Function 61 

Set the Attempts Lockout Time 

See page 24 

Function 62 - 63 

Reserved 

-- 

Function 64 - 65 

Disable/Enable Remote Input  

See page 24 

Function 66 

Ambush Code 

See page 24 

Function 67 

Add Relay/System Features 

See page 25 

Function 68 

Delete All Relay Functions and 
System Options added by 
Function 67 

See page 25 

Function 69 - 70 

Enable/Disable Enter Key  

See page 26 

Function 71 

Reserved 

-- 

Function 72 - 73 

Scheduled Enable/Disable  
Passage Mode 

See page 26 

Function 74 - 77 

Schedule Enable Group 1 - 4 

See page 26 

Function 78 

Schedule Enable All Groups 

See page 26 

Function 79 - 82 

Schedule Disable Group 1 - 4 

See page 26 

Function 83 

Schedule Disable All Groups 

See page 26 

Function 84 - 87 

Quick Schedules - Enable Group 

See page 27 

Function 88 

Passage Mode  

(Open Time Window) 

See page 27 

Function 89 

Passage Mode  

(Close Time Window) 

See page 27 

Function 90 

Relay Activation  

(Open Time Window) 

See page 28 

Function 91 

Relay Activation  

(Close Time Window) 

See page 28 

Function 92 

Enable Group 4  

(Open Time Window) 

See page 29 

Function 93 

Enable Group 4  

(Close Time Window) 

See page 29 

Function 94 - 98 

Reserved 

-- 

Function 99 

Clear All Lock Programming 

See page 29 

Summary of Contents for Trilogy ETPDL

Page 1: ...Access Control Systems with ProxCard Access WI1021C 9 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASD...

Page 2: ...ader and a real time clock calendar that automatically adjusts for Daylight Saving Time and allows for automated programming of events Features three methods of programming 1 all fea tures can be prog...

Page 3: ...nctions see page 17 21 User Access Methods Keypad Entered User Codes see pages 12 13 16 ProxCard and ProxKey Keyfob see page 13 User Code and ProxCard For highest security see page 13 Batch Enroll Qui...

Page 4: ...ation Double ended Mini Banana Plug Connector After you create the program in DL Windows and transfer the program from your computer to an AL DTM transfer the program from the AL DTM to the lock s via...

Page 5: ...r lock to start working To begin programming you must first enter something called Program Mode What is Program Mode Most technical people find working with hardware easy they use tools to make fixes...

Page 6: ...sses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming task...

Page 7: ...associated with User 300 User 297 does this by first entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock al lows access for...

Page 8: ...ser Type For example PDL Series locks can hold up to 2000 Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology secti...

Page 9: ...Mode Information If a wrong key is pressed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All progr...

Page 10: ...ode to send or receive data Using DL Windows IBM COMPATABLE LAPTOP OR DESKTOP PC NOTE OBSERVE TAB DIRECTION WHEN INSERTING CABLE INTO LOCK AL PCI CABLE CONNECT TO SERIAL PORT COM 1 4 PDL3000 LOCK Scen...

Page 11: ...battery pack 2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all ca pacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not he...

Page 12: ...ode to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly...

Page 13: ...three times the card has been enrolled 4 Press to end the process To return to normal operation exit Program Mode see below For example you wish to enroll two ProxCards for User 14 and User 15 respec...

Page 14: ...Security Access ProxCard User Code Test ProxCard programmed for High Security Access A ProxCard and User Code are both required for access 1 Enter the User Code for the User Number programmed for High...

Page 15: ...gramming Functions Overview Function 48 Enable Passage Mode See page 22 Function 49 Disable Passage Mode See page 22 Function 50 Return Lock to Normal Passage Mode Schedule See page 22 Function 51 Pas...

Page 16: ...is Keypad Code Access only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes 3 M USERS Lock Defaults for PDL3000 3500 ETPDL See page 8 Users added will...

Page 17: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Page 18: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Page 19: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Page 20: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Page 21: ...xample if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 second...

Page 22: ...ode is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...

Page 23: ...Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDO...

Page 24: ...OUT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enab...

Page 25: ...rammed relay features Subsequent relay feature pro gramming will not take effect while this feature is active Before pro gramming any other relay features press 6 8 0 0 0 to delete this feature Use Fu...

Page 26: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Page 27: ...Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled P...

Page 28: ...of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NO...

Page 29: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 30 For day ent...

Page 30: ...To Disarm a Burglary Control Panel on page 28 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of tim...

Page 31: ...of the alarm panel Functions 92 93 Use Function 92 and 93 see page 29 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1...

Page 32: ...apply 1 Remote Input switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow A...

Page 33: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 34: ...programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter...

Page 35: ...LE A device that permits transfer of program data between a computer and the lock DATE Month Day and Year entered as MMDDYY DAY OF WEEK Sunday through Saturday where 1 Sunday and 7 Saturday DEFAULT De...

Page 36: ...ll have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire...

Reviews: