24
;62 ;
[ _ _ _ _ ]
;
[ _ _ _ _ _ _ ]
:
(User Number) (User Code)
60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
LOCKOUT
; 6 4 :
64. Disable Remote Input
Remote Input
; 6 5 :
65. Enable Remote Input
66. Reserved
•
Number of attempts before lockout must be 1-9 attempts.
•
The number of attempts is reduced by half every time the keypad is locked out without a successful code entry (default is
6 attempts).
•
The attempt count is reset each time a valid code is entered.
•
Lockout Time must be 1-60 seconds.
How long the keypad is locked-out after a series of unsuccessful attempts (default is 18 seconds).
•
Wire a Normally Open Contact to Wires (White & White). Momentarily close switch to unlock door to allow person to pass through door.
•
Enter the functions below to Disable/Enable the Remote Input.
NOTE:
The Remote Input is enabled as part of the default program.
REMOTE INPUT
; 6 0 ;
[ _ ]
:
(Number of Attempts)
; 6 1 ;
[ _ _ ]
:
(Lockout Time)
Programming Functions (cont'd)
59. Reserved
4
2
62. Add/Delete/Change User Codes 2-2000
(for Primary Side code entry)
•
User Number must be between 2 and 2000. User Codes entered are enabled for use with the Primary side keypad only.
•
To delete a code, leave the User Code blank and wait for the rapid beeping to stop, then press and hold
:
for three seconds
to exit Programming Mode. If more programming is desired, re-enter Programming Mode.
•
User Code must be 3-6 digits.
•
Each User Code can be thought of as a person. As long as each person possesses their own unique User Code, you can con-
trol access to the lock by adding or deleting User Codes. See "Terminology Used in this Manual" on page 6 for more information.
3
4
;63 ;
[ _ _ _ _ ]
;
[ _ _ _ _ _ _ ]
:
(User Number) (User Code)
63. Add/Delete/Change User Codes 2-2000
(for Secondary Side code entry)
•
Same as Function 62, except User Codes entered are enabled for use with the Secondary side keypad only.
3