16
1. New Master Code
(User Number 1)
2. Add/Delete/Change User Codes 2-2000
(Access through either side)
; 1 ;
[ _ _ _ _ _ _ ]
;
[ _ _ _ _ _ _ ]
:
(New Master Code) (Confirm New Master Code)
; 2 ;
[ _ _ _ _ ]
;
[ _ _ _ _ _ _ ]
:
(User Number) (User Code)
•
User Number must be between 2 and 2000.
•
User Codes added with this feature are enabled to pass from
either side of the lock
. To add User Codes for use with
only the Primary Lock Side or only the Secondary Lock Side, see Functions 62 and/or 63.
•
To delete a code, leave the User Code blank and wait for the rapid beeping to stop, then press and hold
:
for three
seconds to exit Programming Mode. If more programming is desired, re-enter Programming Mode.
•
User Code must be 3-6 digits.
•
Each User Code can be thought of as a person. As long as each person possesses their own unique User Code, you
can control access to the lock by adding or deleting User Codes. See "Terminology Used in this Manual" on page 6 for
more information.
•
Master Code must be 6 digits-only.
•
Master Code is Keypad Code Access only.
•
Factory Default =
123456
•
See "Lock Design Overview" on page 5 for more information about Master Codes.
3
M
USERS
Lock Defaults for
DL5300
See page 8. Users added
will default to a Group Association and a Program Level Ability as follows:
USER TYPE
USER NUMBER
GROUP DEFAULT
ASSOCIATION
MINIMUM PROGRAM
LEVEL (see page 6)
Master
1
-
M
(All Programming Abilities)
Installers
2 & 3
none
4
(Also 3, 2, 1)
Managers
4 - 6
none
3
(Also 2, 1)
Supervisors
7 - 9
none
2
(Also 1)
Print Only Users
10 - 11
none
1
Basic Users
12 - 50
none
none
Basic Users in Group 1
51 - 100
1
none
Basic Users in Group 2
101 - 150
2
none
Basic Users in Group 3
151 - 200
3
none
Basic Users in Group 4
201 - 250
4
none
Basic Users
251 - 296
none
none
Quick Enable User 300
297
none
none
Quick PC Access
298
none
none
AL-DTM Code
299
none
none
Service User
300
none
none
Basic Users
301-2000
none
none
Programming Functions