Add Users with the Global Users Screen 

Overview 

The 

Global Users 

screen is used to enter all User information.  

Users can be assigned to specific locks and assigned to Groups 
within locks.  All Basic Users are entered here as well as the Level 
Assignment for DL3000/2800 locks.  User lists can be imported from 
other DL-Windows Accounts or from comma delimited formatted lists.  
Administrative Users can be accessed through the 

Global Users 

screen via the 

Add Administrative Users

 button.  Please see page 

29 for the 

Global Users 

screen layout and field descriptions. 

 

Add Users and User Codes 

As shown in the image below, type the first and last name of a User 
in the 

User Information Fields

, and enter the remaining personal 

information as needed.  Note that the names entered in the 

First 

Name 

and 

Last Name

 fields also appear in the 

User Name 

list.  

Note:

  A specific PIN Number ("User Code") may be typed in the 

Pin 

No.

 field for each User --or-- random User Codes may be auto-

generated for one or many Users by right-clicking in the 

User Name 

list.  In addition, a 

Custom Field 

(located under the 

Pin No.

 field) 

allows a customized field of up to 15 characters.  This field is set in the 

Options 

screen (click the 

Opt 

button) and once changed remains 

identical for all locks in all Accounts. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note:  

The 

ID

 column in the 

User Name

 list is used for identifying 

Users 

in this screen only 

and is NOT associated with positions in 

the 

Lock Data

 screen.  For this reason, if displaying these 

numbers is confusing, this column may be hidden using the 

Options

 screen (see page 41 for more information). 

 

The 

LockID Grid 

displays LockID numbers and is color-coded to 

describe the state of the selected User: 

Green = User entered in the lock and enabled 

Red = User entered in the lock but disabled 

White = User not in the lock 

 

Double-click on a 

LockID Grid 

number 

to cycle through the colors of the 
LockID number (from 

white 

to 

green 

to 

red 

and back to 

white

) thus adding, 

disabling or removing a User as 
needed.  In this way, the 

LockID Grid 

can be used to add a User to any lock 
in an Account.  One or multiple Users 
can also be added to one or more locks 
via the right-click menu in the 

User 

Name 

list. 

Select a Range of Users 

 
 
 
 
 
 
 
 
 
 
 
 
To select a range of Users, click to select the first User, press and hold 
the 

SHIFT

 key, then click the last User in the range (you can also 

press 

CTRL 

and click individual Users).  Within the range of Users 

highlighted, right-click in the highlighted area to display the menu 
shown above.  Click a selected action in the menu to perform the 
action for the selected Users.   

 

Random User Code Generation 

Random User Codes may be generated for one or many Users.  
(

Note:

  To avoid User Number conflicts, it is recommended to first 

assign specific User Codes to Users before selecting random User 
Code generation).  To generate random Codes, press and hold the 

CTRL

 key, click the right arrow ("

") located to the left of the 

User 

Name 

to select each User(s), then right-click and select “

Generate 

Selected New Codes

”.  You can select a range of Users (as 

described above) and click 

Generate All New Codes 

to create new 

codes for all Users.   

 

Adding a User to a Group/Level 

In the Global Users Screen, select a range of Users or click individual 
Users as described in the section "

Select a Range of Users

" (above), 

then click the 

Set Group Assignment

 button to display this screen: 

 
 
 
 
 
 
 
 
 
 
In the above dialog, rows represent Groups and columns represent 
locks (the number above each column is the LockID number).  
Double-click in the grid to add the User to a Group in a single lock 
(hold down the 

Ctrl

 key to allow single-click entry).  To save time, 

check the appropriate check box to add the User to the same Group 
in all locks.  When finished, click 

Add Selected Users to These 

Groups

 to add the selected Users to the Groups highlighted in 

green.  The same procedures apply to the 

Set Level Assignment

 

button and 

Set Level Assignment For User 

screen (note that 

Levels

 are only associated with the DL3000 and DL2800 locks). 

 

Administrative Users 

The 

Add Administrative 

Users

 button displays the 

Set Administrative Users 

screen.  Administrative 
Users are the same for all 
locks within an Account. 

 

Enter information the same 
way as if adding a basic 
User. 

 

Lock Grid 

To add a selected 
User, double-click on a 

LockID 

number box.   

To highlight a range of Users, 
click in this column to select the 
first User, press and hold the 

SHIFT

 key, then click the last 

User in the range… 

...then right-
click and select 
from any of 
these options. 

Right-click menu in 
the 

User Name 

list 

User 
Information 
Fields 

The 

LockID Grid

 

displays LockID 
numbers 

In this example, for LockID #6, 
double-click in a box (1-4) to 
set the Group assignment for 
this User. 

 

Summary of Contents for DL-WINDOWS V3.6.0

Page 1: ...0 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2007 Downloading Software for the Trilogy Line of Standalone Access Control Systems PDL3500 PDL4500 RESIDENCY LOCK PDK3000 DK3000 DL3000 DL4100 PRIVA...

Page 2: ...Screen Field Definitions 30 Lock Data Screen Field Definitions 31 Event Log Viewer Screen Field Definitions 32 Programmable Features Screen Options tab 33 Programmable Features Screen Customize DST 34...

Page 3: ...tiple Locks see page 15 Allows you to save time when creating a new lock Cloning duplicates all schedules and Users programmed from an existing lock You can clone up to 2000 locks of the same lock typ...

Page 4: ...e this cable to transfer the Lock Program from your lock to an AL PRE DB9 to DB9 Serial Cable supplied Enroll ProxCards quickly into DL Windows then transfer this new ProxCard data from the computer t...

Page 5: ...use you do not have to transport or find electricity for your computer Data can also flow in reverse from the lock through the AL DTM back to the computer for examination IBM COMPATABLE LAPTOP OR DESK...

Page 6: ...to the lock are organized by their Function Number Want to change the date inside the lock Use Function Number 38 Want to add a User Code Use Function Number 2 With DL Windows you first use the vario...

Page 7: ...example every Tuesday at 5PM that are referred to as TimeZones You use the Schedule TimeZone screen to create these TimeZones and once created you can link events to these TimeZones Note The Schedule...

Page 8: ...u wish to allow one time access to a temporary worker Simply enter the User 297 User Code into the lock keypad Later when the temporary worker enters the User 300 User Code into the lock keypad the Us...

Page 9: ...using the Schedule TimeZone screen Feat Opens the Programmable Features dialog which allows you to choose various Options within the DL Windows software Log Open the Event Log Viewer screen to examine...

Page 10: ...tup and Test Import CSV File Import CSV File From Excel Import CSV File From DL Windows Export Active Account to CSV Import a Single ADF Account File Backup Accounts Check for Ambush Code Conflict Com...

Page 11: ...3 Add Users and other data using Global Users screen see page 16 4 Enroll ProxCards for PDL locks only see page 17 5 Add Schedules and TimeZones see page 20 6 Send Information to the lock see page 21...

Page 12: ...port that passes the DL Windows automatic detection test will be selected When finished click Exit Note If you are not using COM1 you must run this utility to identify the active comm port Starting D...

Page 13: ...t the directory the Import Utility will use When selecting your database files the Files of type pull down menu lists two file types New DL Windows Index files Old DL Windows Index files The Old file...

Page 14: ...d field type a new password in the New Password field and re type the same new pass word in the Confirm field 3 Press Enter on your keyboard to accept the changes DL Windows can utilize a Security Pas...

Page 15: ...to delete an Account right mouse click the name of the Account and select Delete Account from the menu A warning popup will appear and click Yes to confirm and click No to can cel Add Locks to the Ac...

Page 16: ...ct the first User press and hold the SHIFT key then click the last User in the range you can also press CTRL and click individual Users Within the range of Users highlighted right click in the highlig...

Page 17: ...he Add Cards button The ProxCard Enrolling dialog opens The AL PRE is now ready to accept Prox entries 5 In the ProxCard Enrolling dialog right check Enable AL PRE Enroll ProxCards with the AL PRE DB9...

Page 18: ...below To manually add proximity information first uncheck Enable AL PRE The Card No and Facility fields become active as shown in the following image If you choose to add the Proximity data manually...

Page 19: ...pe manually by selecting User Defined You will need the HID form like the one shown below With out this you will not be able to complete this entry and possibly corrupt your data If you have this data...

Page 20: ...a single ended schedule is a single Lock event with the TimeZone 1 start time set to 5 00 PM only This schedule will cause the device to lock every day at 5 00 PM An example of a double ended schedul...

Page 21: ...y of entering a Master or Manager Code entering Program Mode and inputting Function 58 Simply enter User 298 s User Code to initiate PC communications with the lock It is an option with all the locks...

Page 22: ...een Verify that this information is correct 5 If Communicating is not displayed after Step 3 as shown in the image below then communications have failed Check the following a COM Port Selection b Cabl...

Page 23: ...r data was changed at the lock Because DL Windows will not automatically receive and accept User changes made at the lock if you wish to retain the data displayed in the Lock Differences screen you mu...

Page 24: ...e Max Event Log Length pull down list as shown in the image below When using a PC the complete log up to a maximum of 40 000 events can be received When Update Group Status is selected in the Receive...

Page 25: ...to PC COMM MODE If not already in PC COMM MODE press green button to enter this mode 2 Press and HOLD both the left and green buttons on the AL DTM After several messages appear release the buttons wh...

Page 26: ...tion of User 299 1 Plug the AL PCI2 cable into the correct COM port in your PC and plug the 2 pin banana plug connector into the AL DTM observing correct tab direction 2 Open an Account in DL Windows...

Page 27: ...Steps for each lock to be programmed Make sure that each Lock is being assigned the correct LockID This will ensure that the locks are programmed Re enter 299 Code to Continue Door 0001 Send PGM Packe...

Page 28: ...d to retrieve event logs 1 In DTM Support screen click in the DTM Function column for the selected lock click the down arrow and the pull down menu will display Select the Receive Log Function Multipl...

Page 29: ...orrect identity Includes Custom Field described below User Name Names appear in this column when First Name and Last Name fields in this screen are populated Field turns yellow when both a User Code a...

Page 30: ...the Master Code is highlighted displaying the default User information in the window with the fields ready to be populated ProxCard Data Use the AL PRE to enroll ProxCards and ProxKey keyfobs and the...

Page 31: ...User s department or the shift to which the User is assigned If any User attempts to access the lock outside of the Group s scheduled hours the lock will deny entry Indicates the current status of the...

Page 32: ...Log Viewer screen is used to view each event also called the Audit Trail The date the event occurred MM DD YY Click the heading to sort its contents The time the event occurred in 24 hour military ti...

Page 33: ...For version 3 5 6 see page 53 The above screen is from a PDL3000 lock Note the Daylight Saving Time area includes the 24 pre programmed modes as well as a 25th mode to allow customization selecting mo...

Page 34: ...ill take place at 2 00 AM the days selected Click OK to save and click Cancel to discard changes Programmable Features Screen Customize DST Click the pull down menu and a calendar will appear Daylight...

Page 35: ...e an alert that an unauthorized Use Code entry has been detected Will activate relay anytime a User enters a valid User Code and is granted access Will activate relay if the lock has been programmed f...

Page 36: ...ough the door without the need for a User Code Remote input disables the lock while a short is maintained across remote input Therefore if a switch is used for the remote input as long as the switch i...

Page 37: ...he 4100 series lock can be programmed to disable User Code and PROX card access for up to 250 minutes When active all User Numbers 12 and higher are disabled and User Numbers 1 11 or a key can always...

Page 38: ...to occur only on this specific day every month of the year Double click on the day s desired If the day is enabled a 9 will appear under the Enable column Add TimeZone Click the Add Button the Select...

Page 39: ...ly two columns for one event and the third column is left blank all information for the event will be automatically deleted At any time all programmed schedules can be printed by clicking on Print Sch...

Page 40: ...his is the Day of the Week entered in the TimeZone area of the Schedule TimeZone screen This is the time entered in the TimeZone area of the Schedule TimeZone screen This is the Event entered in the S...

Page 41: ...obal Users screen and simply lists all potential Users within an Account DL Windows keeps track of each Global User listed in the Global Users screen by use of the Global ID number The number acts as...

Page 42: ...ou to combine Users from one Account with another Account Before using either Import utility first open the Account to which the data will be imported If the Account does not yet exist a new test Acco...

Page 43: ...ion folder if you selected the default folders look in C DL Windows Highlight the Account files you wish to transfer hold down the Ctrl key and click on each file Right click the highlighted files and...

Page 44: ...onfigurations Use this button after the AL DTM had valid data loaded from the lock Data will be received from all locks that have been selected in the DTM Support screen The DTM Support screen will re...

Page 45: ...ams from DL Windows to AL DTM Receive multiple lock logs or lock programs stored in the AL DTM back to DL Windows 2 LOCK Mode AL DTM Lock Communications Transfer lock program from the AL DTM to a spec...

Page 46: ...If database errors occur within Accounts click Tools Compact and Repair To ensure that your Account data is not lost you can back up all of your Accounts into a single folder Simply click Tools Backup...

Page 47: ...he Find phrase No field and press ENTER on your keyboard Changing the Default Language On the toolbar click Opt and the Options dialog opens see below Additional languages are available in the Select...

Page 48: ...unlock event adding the days when the lock should remain locked In the example shown below the lock will remain locked on the 4th of July Click the Select TimeZone pull down menu and select TimeZone 2...

Page 49: ...k will stay locked all day This feature allows for a window of time to be created where if any Group 1 User Code is entered within the programmed window a relay will be activated for 2 seconds This re...

Page 50: ...he Change Password dialog type the existing password in the Old Password field type a new password in the New Password field and re type the same new password in the Confirm field Press f on your keyb...

Page 51: ...nnect the double ended banana plug into the AL DTM and into the lock that is to be programmed observing proper tab direction 3 Press the Green Button on the AL DTM until the AL DTM displays the follow...

Page 52: ...iving PGM Packet 008 Lock s Time and Date Updated Comm Complete 07 24 04 02 28PM Current date and Time 0993 FREE MEMORY BLOCKS Current Memory Status Press the left black button answer YES Waiting for...

Page 53: ...imum number of invalid entry attempts with wrong User Code has been reached valid entries are 1 60 seconds The duration in seconds that the lock will remain unlocked after a valid code has been entere...

Page 54: ...unicate with the Lock and or Data Transfer Module DATA TRANSFER MODULE A device that permits transfer of program data between a computer and the lock DATE Month Day and Year entered as MMDDYY DAY OF W...

Page 55: ...ram data to be entered through the keypad Only specific Users can program a lock manually by entering their USER CODE followed by the key To exit program mode hold any key until repeated beeps are hea...

Page 56: ...n purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALAR...

Reviews: