A-100IMWP Wiring Table  

TWO KEYPADS CONTROL ONE DOOR 

The below diagram displays how to control a single door with two keypads.  When you enter a valid code on Keypad 
2, the magnetic lock unlocks directly.  When you enter a valid code on Keypad 1, the Request-to-Exit input of keypad 
2 is triggered, unlocking the door.  

Note:  

Valid user codes must be programmed into both Keypads 1 and 2. 

Electromagnetic 

Door Lock  

(Fail Safe) 

Electromagnetic 
Door Lock  
(Fail Secure) 

N/O  
Request-
to-Exit 
Button 

WIRING EXAMPLES

 

ONE KEYPAD CONTROLS A 
DOOR 

The diagram at right displays 
basic wiring--how to control a 
single door with one keypad.  
When you enter a valid code on 
Keypad 1, the magnetic lock 
unlocks directly.  This wiring is 
"Fail Secure" which means that if 
power is lost, the door will re-
main locked. 

Visual LED Indicators 

LED 

In Normal Mode 

In Program Mode 

Red 

Remains lit while waiting for a 

keypress 

Confirms errors 

Blinks when editing an existing User Number 

Orange 

Flashes to confirm keypress 

Steady On to confirm in Program Mode.  

Flashes to confirm keypress 

Green  Confirms activation of Outputs, mem-

ory reset and Master Code reset 

Confirms valid data or empty User Number 

Audible Sounder Indicators 

Beep(s) 

In Normal Mode 

In Program Mode 

1 short 

Unit power up and when a key is 

pressed 

Valid data confirmation 

1 long 

Relay activation following a valid 

User Code 

Data recorded 

4 short 

Data error 

Data Error 

2 short 

Enter Program Mode 

Exit Program Mode 

A-100IMWP Wiring Table  

Description 

Wire Colors 

+ 12V or 24V AC/DC Input 

Red 

– Ground 

Black 

Request to Exit Input 

Purple 

Request to Exit Input 

Pink 

Relay 1 Normally Open 

Yellow   

Relay 1 Common 

Brown 

Relay 1 Normally Closed  

Dark Blue 

Relay 2 Normally Open 

Light Blue 

Relay 2 Common 

 

Light Green 

Relay 2 Normally Closed 

 

Orange 

Open Collector Output 

Dark Green 

Tamper SW Output 

Gray 

Tamper SW Output 

White 

12-24 VDC /

VAC Power 

Red 

Blac

Pu
rp

le

 

Pi

nk

 

Ye
llo

w

  

 

Brow

n

 

Dark Blue 

Light Blue 

Light Green 

Orange 

Dar
k Gree

Gr

ay

 

Wh
ite

 

A-100IMWP Wiring Table  

12-24 VDC /

VAC Power 

12-24 VDC /

VAC Power 

Summary of Contents for A-100IMWP

Page 1: ...150 User Codes of 3 to 6 digits Output activation duration programmable from 01 99 seconds program 00 to select toggle mode All programming stored in non volatile EEPROM mem ory Orange LED Keypress fe...

Page 2: ...below Think of a new four digit numeric Master Code and either commit it to memory or write it here ___ ___ ___ ___ Note Only numbers zero through 9 are valid digits for either User Codes or the Mast...

Page 3: ...vation Duration Program time from 01 to 99 seconds Program 00 to select latch mode where output remains activated by the entry of a valid User Code until deactivated by the entry of a second valid Use...

Page 4: ...er G1 User Code G1 re enter User Code G1 Some examples of the 2 digits field press 12 to activate Outputs 1 and 2 press 23 to activate Outputs 2 and 3 press 13 to activate Outputs 1 and 3 press 02 to...

Page 5: ...twhile waiting for a keypress Confirmserrors Blinkswhen editing an existing User Number Orange Flashes to confirmkeypress Steady On to confirmin ProgramMode Flashes to confirmkeypress Green Confirmsac...

Page 6: ...ter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or...

Page 7: ...7 MOUNTING TEMPLATE The A 100IMWP is designed to be installed in its stainless mounting base The base is 1 wide and 6 tall...

Page 8: ...roduct has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered...

Reviews: