4
number of digits in the new Master Code) and--without
exiting Program Mode--change the Master Code via
Function 31.
Press:
31#
[
G1
] (
new MC
)
#
[
G1
] (
new MC
)
#*
[
G1
].
Be sure to either commit the Master Code to memory or
record it in a safe place. If the Master Code is ever lost,
the keypad will need to be restarted using the First Time
Startup procedure described on page 2.
32 Add (or Edit) a User Code
Allows you to add a new or edit an existing
User Code
.
User Codes are 3-6 digit numbers the User presses into
the keypad keys to activate one or more Outputs. The
A-100IMWP keypad can hold up to 150 User Codes in
its memory, thus allowing up to 150 people to possess
their own individual User Codes. The keypad memory
associates each User Code with a 3-digit
User Number
listed from 000 to 149. Therefore, when adding new
User Codes, you must also select a 3-digit User Number
between 000 and 149 that will be associated ("linked")
with the new User Code. As with the Master Code, only
numbers zero through 9 are valid digits for User Codes
(keys
*
or
#
are not allowed) and each User Code
must be unique. Programming requires entering the
new User Code twice for confirmation, as follows:
Press:
32#
[
G1
] (
User Number
)
#
[
G1
] (
User Code
)
#
[
G1
] (
re-enter User Code
)
#*
[
G1
].
33 Add (or Edit) a User Code with Output 1 Duration
Same as Function 32 plus the ability of the individual
User Code to activate Output 1 for a specified duration
(from 01 to 99 seconds). Program 00 to select "latch
mode" where output remains activated by the entry of a
valid User Code (until deactivated by the entry of a sec-
ond valid User Code).
Press:
33#
[
G1
] (
time 01-99
)
#
[
G1
] (
User Number
)
#
[
G1
] (
User Code
)
#
[
G1
] (
re-enter User Code
)
#*
[
G1
].
34 Delete User Code
Overwrites specified User Number with vacant data,
thus erasing the User Code from memory.
Press:
34#
[
G1
] (
User Number
)
#*
[
G1
].
40 Reset Keypad
Erase all existing keypad programming and return the
keypad back to its original "out of box" factory default
condition
Press:
40#
[
G1
]
12345#
[
G1
]
12345#*
[
G1
].
52 Add (or Edit) a User Code with Output Activation
Same as Function 32 plus the ability of the individual
User Code to activate the specified Output(s).
Press:
52#
[
G1
] (
2-digits*
)
#
[
G1
] (
User Number
)
#
[
G1
] (
User Code
)
#
[
G1
] (
re-enter User Code
)
#*
[
G1
].
*
Some examples of the "2-digits" field:
•
press "12" to activate Outputs 1 and 2
•
press "23" to activate Outputs 2 and 3
•
press "13" to activate Outputs 1 and 3
•
press "02" to activate Output 2 only
•
press "10" to activate Output 1 only ...etc.
Note:
If Function 70 ("
Output 3 Activates on First
Keypress
") is enabled, Output 3 cannot be included in
the choices offered by Function 52.
Note:
If “Doorbell Active on Output 2” is enabled, Output
2 cannot be included in the choices offered by Function
52. The value in “Output 2 timer value” (from 01 to 99
seconds) is the duration of relay #2 activation when the
door bell button is momentarily pressed. If the door bell
activation must follow the key press action, then “Output
2 timer value” should be 00.
60 Sounder Beeps
Activate sounder beeping or deactivate when pressing
User Codes only.
Always ON Press:
60#
[
G1
]
1#*
[
G1
].
OFF for User Codes:
60#
[
G1
]
0#*
[
G1
].
Sounder factory default is "Always ON".
70 Output 3 Activates on First Keypress
Enable Output 3 to activate upon any first keypress
when in "Normal Mode" (such as the first keypress when
entering a User Code). Output 3 is a 250mA open col-
lector transistor output. Function 70 can be used for
many purposes, such as to trigger a surveillance camera
to record all activity at the keypad. In addition, Output 3
is silent, therefore Users will be unaware when Output 3
is activated. Function 70 can also be used to deactivate
this feature, as follows:
Activate Press:
70#
[
G1
]
1#*
[
G1
].
Deactivate Press:
70#
[
G1
]
0#*
[
G1
].
Note:
If Function 70 is enabled, Output 3 cannot be in-
cluded in the choices offered by Function 52.
80 Doorbell Feature
Program time from 01 to 99 seconds. Program 00 to
select "latch mode" where output remains activated by
the entry of a valid User Code (until deactivated by the
entry of a second valid User Code).
Note:
By default, a
valid User Code always activates Output 1 unless Out-
put selection is changed.
Activate on Output 2 Press
:
80#
[
G1
]
1#*
[
G1
].
Deactivate Press:
80#
[
G1
]
0#*
[
G1
].
Note:
If “Doorbell Active on Output 2” is enabled, Output
2 cannot be included in the choices offered by Function
52. The value in “Output 2 timer value” (from 01 to 99
seconds) is the duration of relay #2 activation when the
door bell button is momentarily pressed. If the door bell
activation must follow the key press action, then “Output
2 timer value” should be 00.