background image

number of digits in the new Master Code) and--without 
exiting Program Mode--change the Master Code via 
Function 31. 

 

Press:

  

31#

 [

G1

] (

new MC

#

 [

G1

] (

new MC

#*

 

[

G1

]. 

 

Be sure to either commit the Master Code to memory or 
record it in a safe place.  If the Master Code is ever lost, 
the keypad will need to be restarted using the First Time 
Startup procedure described on page 2. 
 

32  Add (or Edit) a User Code 

Allows you to add a new or edit an existing 

User Code

.  

User Codes are 3-6 digit numbers the User presses into 
the keypad keys to activate one or more Outputs.  The 
A-100IMWP keypad can hold up to 150 User Codes in 
its memory, thus allowing up to 150 people to possess 
their own individual User Codes.  The keypad memory 
associates each User Code with a 3-digit 

User Number

 

listed from 000 to 149.  Therefore, when adding new 
User Codes, you must also select a 3-digit User Number 
between 000 and 149 that will be associated ("linked") 
with the new User Code.  As with the Master Code, only 
numbers zero through 9 are valid digits for User Codes 
(keys 

*

 or 

#

 are not allowed) and each User Code 

must be unique.  Programming requires entering the 
new User Code twice for confirmation, as follows: 

 
 

Press:

   

32#

  [

G1

] (

User Number

#

  [

G1

] (

User Code

#

 [

G1

] (

re-enter User Code

#*

 [

G1

]. 

 

33  Add (or Edit) a User Code with Output 1 Duration  

Same as Function 32 plus the ability of the individual 
User Code to activate Output 1 for a specified duration 
(from 01 to 99 seconds).  Program 00 to select "latch 
mode" where output remains activated by the entry of a 
valid User Code (until deactivated by the entry of a sec-
ond valid User Code). 

 

Press:

   

33#

  [

G1

] (

time 01-99

#

  [

G1

] (

User Number

#

  [

G1

] (

User Code

#

  [

G1

] (

re-enter User Code

#*

 [

G1

]. 

 

34  Delete User Code 

Overwrites specified User Number with vacant data, 
thus erasing the User Code from memory. 

 

Press:

  

34#

 [

G1

] (

User Number

#*

 [

G1

]. 

 

40  Reset Keypad 

Erase all existing keypad programming and return the 
keypad back to its original "out of box" factory default 
condition 

 

Press:

  

40#

 [

G1

12345#

 [

G1

]  

               

12345#*

 [

G1

]. 

 

52  Add (or Edit) a User Code with Output Activation 

Same as Function 32 plus the ability of the individual 
User Code to activate the specified Output(s).   

 

Press:

  

52#

 [

G1

] (

2-digits*

#

 [

G1

] (

User Number

#

 

[

G1

] (

User Code

#

  [

G1

] (

re-enter User Code

#*

 [

G1

]. 

 

*

Some examples of the "2-digits" field: 

press "12" to activate Outputs 1 and 2 

press "23" to activate Outputs 2 and 3 

press "13" to activate Outputs 1 and 3 

press "02" to activate Output 2 only  

press "10" to activate Output 1 only ...etc. 

 

Note:

  If Function 70 ("

Output 3 Activates on First 

Keypress

") is enabled, Output 3 cannot be included in 

the choices offered by Function 52. 

 

Note: 

 If “Doorbell Active on Output 2” is enabled, Output 

2 cannot be included in the choices offered by Function 
52.  The value in “Output 2 timer value” (from 01 to 99 
seconds) is the duration of relay #2 activation when the 
door bell button is momentarily pressed.  If the door bell 
activation must follow the key press action, then “Output 
2 timer value” should be 00. 

 

60  Sounder Beeps 

Activate sounder beeping or deactivate when pressing 
User Codes only.   

 

Always ON Press:

  

60#

 [

G1

1#*

 [

G1

]. 

OFF for User Codes:

  

60#

 [

G1

0#*

 [

G1

]. 

 

Sounder factory default is "Always ON". 
 

70  Output 3 Activates on First Keypress 

Enable Output 3 to activate upon any first keypress 
when in "Normal Mode" (such as the first keypress when 
entering a User Code).  Output 3 is a 250mA open col-
lector transistor output.  Function 70 can be used for 
many purposes, such as to trigger a surveillance camera 
to record all activity at the keypad.  In addition, Output 3 
is silent, therefore Users will be unaware when Output 3 
is activated.  Function 70 can also be used to deactivate 
this feature, as follows: 

 

Activate Press:

  

70#

 [

G1

1#*

 [

G1

]. 

Deactivate Press:

  

70#

 [

G1

0#*

 [

G1

]. 

 

Note:

  If Function 70 is enabled, Output 3 cannot be in-

cluded in the choices offered by Function 52. 
 

80  Doorbell Feature 

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code).  

Note:

  By default, a 

valid User Code always activates Output 1 unless Out-
put selection is changed. 

 

Activate on Output 2 Press

:

  

80#

 [

G1

1#*

 [

G1

]. 

Deactivate Press:

  

80#

 [

G1

0#*

 [

G1

]. 

 

Note: 

 If “Doorbell Active on Output 2” is enabled, Output 

2 cannot be included in the choices offered by Function 
52.  The value in “Output 2 timer value” (from 01 to 99 
seconds) is the duration of relay #2 activation when the 
door bell button is momentarily pressed.  If the door bell 
activation must follow the key press action, then “Output 
2 timer value” should be 00. 

Summary of Contents for A-100IMWP

Page 1: ...150 User Codes of 3 to 6 digits Output activation duration programmable from 01 99 seconds program 00 to select toggle mode All programming stored in non volatile EEPROM mem ory Orange LED Keypress fe...

Page 2: ...below Think of a new four digit numeric Master Code and either commit it to memory or write it here ___ ___ ___ ___ Note Only numbers zero through 9 are valid digits for either User Codes or the Mast...

Page 3: ...vation Duration Program time from 01 to 99 seconds Program 00 to select latch mode where output remains activated by the entry of a valid User Code until deactivated by the entry of a second valid Use...

Page 4: ...er G1 User Code G1 re enter User Code G1 Some examples of the 2 digits field press 12 to activate Outputs 1 and 2 press 23 to activate Outputs 2 and 3 press 13 to activate Outputs 1 and 3 press 02 to...

Page 5: ...twhile waiting for a keypress Confirmserrors Blinkswhen editing an existing User Number Orange Flashes to confirmkeypress Steady On to confirmin ProgramMode Flashes to confirmkeypress Green Confirmsac...

Page 6: ...ter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or...

Page 7: ...7 MOUNTING TEMPLATE The A 100IMWP is designed to be installed in its stainless mounting base The base is 1 wide and 6 tall...

Page 8: ...roduct has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered...

Reviews: