background image

Orange LED lights  - sounder beeps twice. 

2.   

Press 

34#

  

Green LED blinks once - sounder beeps once. 

3.   

Press the 3-digit User Number 

associated with the 

User Code you wish to delete and press 

#*

.   

Green LED lights / sounder beeps for 1 second indi-
cating the User Code was deleted successfully.   

 

Exit Program Mode 

When you finish programming and wish to put the keypad 
into use, you exit Program Mode to enter "Normal Mode" 
as follows: 

 

Exit Program Mode

:  Press 

*

 

The orange LED turns off, the sounder beeps twice and 
the red LED lights.  

Note:

  The keypad will automatically 

exit Program Mode if no keys are pressed within 120 sec-
onds (2 minutes).   
 

Test the Keypad 

Be sure to test all User Codes.  Keep in mind the follow-
ing: 

Valid User Codes must be followed by the star (

*

) key 

Master Code and User Codes must all be the same 
length 

By default, a valid User Code always activates Output 1 
unless Output selection is changed 

 
 
 

ALL PROGRAMMING FUNCTIONS 

 
Your keypad is designed to support several options and 
functions.  Using the keypad, you can select the features 
you wish to activate, such as if the keypad sounder should 
be disabled or enabled or you wish to change the code 
length from 4 to 6 digits.. 

 

Each function is organized below by its function number, 
which is the first two digits pressed into the keypad when 
programming.  To program, first enter Program Mode as 
follows: 

 

Enter Program Mode

:  Press 

55#

  [

Master Code

*

 

When you finish programming and wish to put the key-
pad into use, exit Program Mode to enter "Normal Mode" 
as follows: 

 

Exit Program Mode

:  Press 

*

 

Note: 

 The audible sounder and visual LED indicators 

are displayed in the text below as follows: 

 

[

O2

] = Orange LED lights and sounder beeps twice 

[

G1

] = Green LED lights and sounder beeps once 

[

R2

] = Red LED lights and sounder beeps twice 

 

Note:

  Every duration field is a two digit field.  Master code 

is strictly reserved for entering Program Mode and cannot 
be used to activate an Output.   

 
 

21  Output 1 Activation Duration  

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code).  

Note:

  By default, a 

valid User Code always activates Output 1 unless Out-
put selection is changed. 

 

Press:

  

21#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

22  Output 2 Activation Duration  

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code). 

 

Press:

  

22#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

23  Output 3 Activation Duration  

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code). 

 

Press:

  

23#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

24  Illuminated Keypad 

Turns illuminated keypad ON, OFF or allows the illumi-
nation to remain ON for a specified duration after 
keypress (the duration is programmed by Function 25).   

 

Always ON Press:

  

24#

 [

G1

0#*

 [

G1

]. 

Always OFF Press:

  

24#

 [

G1

1#*

 [

G1

] and 

do NOT program Function 25. 

Timed ON Press:

   

24#

  [

G1

1#*

  [

G1

] and 

program Function 25 with two-digit time duration. 

 

25  Illuminated Keypad Duration  

See function 24.  Program time from 10 to 99 seconds. 

 

Press:

  

25#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

30  Code Length  

Changes the number of required digits in all new User 
Codes and the existing Master Code.  3-6 digits are al-
lowed, thus valid entries are "3", "4", "5" or "6".  The fac-
tory default Code Length is 4. 

 

WARNING: 

 When the Code Length is changed, all ex-

isting User Codes and the Master Code become invalid.  
Because the Master Code and all User Codes must 

al-

ways 

be the same number of digits in length, if you 

change the Code Length with Function 30 you MUST 
remain in Program Mode and change the Master Code 
to conform to the new programmed "Code Length".   

 

Press:

  

30#

 [

G1

] ___ 

#*

 [

G1

]. 

 

31  Modify Master Code 

Changes existing Master Code.  

Note:

  The Master 

Code and all User Codes must 

always 

be the same 

number of digits in length.  If changing the number of 
digits in the Master Code, you must first change the 
Code Length via Function 30 (to accommodate the new 

Summary of Contents for A-100IMWP

Page 1: ...150 User Codes of 3 to 6 digits Output activation duration programmable from 01 99 seconds program 00 to select toggle mode All programming stored in non volatile EEPROM mem ory Orange LED Keypress fe...

Page 2: ...below Think of a new four digit numeric Master Code and either commit it to memory or write it here ___ ___ ___ ___ Note Only numbers zero through 9 are valid digits for either User Codes or the Mast...

Page 3: ...vation Duration Program time from 01 to 99 seconds Program 00 to select latch mode where output remains activated by the entry of a valid User Code until deactivated by the entry of a second valid Use...

Page 4: ...er G1 User Code G1 re enter User Code G1 Some examples of the 2 digits field press 12 to activate Outputs 1 and 2 press 23 to activate Outputs 2 and 3 press 13 to activate Outputs 1 and 3 press 02 to...

Page 5: ...twhile waiting for a keypress Confirmserrors Blinkswhen editing an existing User Number Orange Flashes to confirmkeypress Steady On to confirmin ProgramMode Flashes to confirmkeypress Green Confirmsac...

Page 6: ...ter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or...

Page 7: ...7 MOUNTING TEMPLATE The A 100IMWP is designed to be installed in its stainless mounting base The base is 1 wide and 6 tall...

Page 8: ...roduct has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered...

Reviews: