3. Insert the magnet into the nibs on the top cover and press the magnet clip down over the magnet until it clicks into
place into the cover.
Figure 6: Case tamper switch installation
Power Up
To power up the module and panel and start communication between them, do the following:
1. Verify that all wiring between the panel and module is correct.
2. Connect the backup battery and restore AC power to the panel.
Note
: Whenever the module is added or changed, remove panel power and reapply it for the panel and module to
communicate successfully.
3. Enter installer program mode and turn off the Access Code Lock feature (Security menu). This must be set to off
for the system to communicate with Alarm.com. The module PWR LED should turn on. After a few seconds, the
module BUS and AUTO LEDs should flash to indicate successful communication with the panel.
4. Verify that LTE status LED L1 is not flashing any errors (see Module Status LEDs on page 4). Also, verify that LED
L4 is flashing an LTE signal level of two or higher. Otherwise, relocate the module. If LED L1 and LED L4 are not
flashing, and LED L2 and LED L3 are flashing together, the module is in PowerSave Mode and the battery needs
to be charged.
Perform an installer LTE manual phone test
To perform a phone test using the system touchpad:
1. Press
[8]
.
2. Enter the installer code.