Translation from the original operating instruction
18
AL-KO AIR HEATER / AIR COOLER INDUSTRY
3.4
Condensate pump
The compact condensate pump is suited for removing accumulated condensate. The condensate pump is a self-priming
rotation membrane pump with condensate sensor.
The condensate is pumped through a flexible condensate pipe with an internal diameter of 6 mm.
Please take note of the installation and safety instructions in the chapter assembly.
3.5 Accessory
Bracket K
Bracket Set K is suited for wall and ceiling mounting of the air heaters and for wall mounting of the air coolers. It consists
of two brackets and the fastening screws for the air heater.
Type
B
mm
H
mm
C
mm
D
mm*
Weight
kg**
K-140
420
432
310
270
2.1
K-250
420
507
385
270
2.2
K-400
420
622
500
270
2.4
K-650
490
732
610
340
2.9
K-1000
540
882
760
390
3.3
* Distance Wall - air heater
** Weight of one bracket
Bracket KD
The KD bracket set is suitable for ceiling mounting of the air heating devices of Type N and NF with the MLK mixed air
box. The bracket is directly attached to the mixed air box. The distance of the mixed air box to the ceiling is approx. 10
cm. The set consists of two brackets and the fastening screws for the mixed air box.
Type
L
mm
n
mm
B
mm
Weight kg*
KD-140
437
1
357
1.2
KD-250
512
1
432
1.3
KD-400
627
2
273.5
1.6
KD-650
737
2
328.5
1.9
KD-1000
887
3
269
2.3