GB
40
LSV 6, LSV 7, LSV 8
Start-up
5. Insert locking pin (06/2) into the aligned
bores of transverse bracket (06/3) and oper-
ating arm (06/4) as far as it will go.
6. Push spring cotter pin (06/1) into the bore of
locking pin (06/2) until it engages.
5.3
Installing splitting table (07, 08)
The splitting column has lateral brackets (07/1) at
three heights for installation of splitting table
(07/2) so that the height of the table can be
adapted to the different lengths of the logs to be
split.
1. Loosen locking screw (08/1) of lateral bracket
(08/2) until splitting table (08/3) can be
pushed in.
2. Position splitting table at an angle on fixing
block (08/4) and push into the lateral bracket
as far as it will go. Lower the splitting table
onto the fixing block until it is finally in the
horizontal position (08/a).
3. Insert the locking screw through bore (08/5)
of the splitting table to fix it in place.
Proceed analogously in reverse order to remove
the splitting table.
5.4
Installing splitting cross [LSV 7, LSV 8]
(09)
1. Push splitting cross (09/1) onto splitting
wedge (09/2) as far as it will go (09/a).
2. Insert screw (09/3) into the bore of the split-
ting wedge to secure the splitting cross.
3. Tighten screw (09/4) securely to push the
splitting cross upwards.
5.5
Adjusting retaining claws [LSV 7, LSV 8]
(10)
Each operating arm has a retaining claw. The re-
taining claws can be adjusted according to the di-
ameter of the logs to be split. Adjust both retain-
ing claws to the same dimension:
1. Loosen both locking screws (10/1) of retain-
ing claw (10/2).
2. Push retaining claw (10/2) to the required di-
mension.
3. Tighten both locking screws (10/1).
6
START-UP
6.1
Setting up and connecting log splitter
DANGER!
Risk of electric shock if
the log splitter is operat-
ed without residual cur-
rent circuit breaker
Operation of the appliance
without residual current cir-
cuit breaker in the mains
connection can result in
serious injuries or even
death due to electric
shock.
■
Before connecting the
appliance, check wheth-
er the mains connection
has a residual current
circuit breaker for a
maximum leakage cur-
rent of 0.03 A.
■
If you cannot be sure
that a residual current
circuit breaker is in-
stalled: Use an addition-
al portable residual cur-
rent device with
switched PE conductor.
Summary of Contents for 113601
Page 5: ...442310_a 5 14 1 2 15 a a b b c 16 1 1 1 1 1 2 3 17 1 2 3 4 5 6 7 8 18 1 2 a b...
Page 7: ...442310_a 7...
Page 224: ...224 LSV 6 LSV 7 LSV 8 LSV 6 LSV 7...
Page 225: ...442310_a 225 LSV 8...
Page 226: ...226 LSV 6 LSV 7 LSV 8...
Page 227: ...442310_a 227...