The unit seems too loud to me: 

 

 

Check that the unit has a firm stand with all four castors and is not uneven. Quieter operation is achieved if the 
air conditioner is placed on a carpet or a piece of floor mat. Furthermore, a short exhaust hose for the warm air 
in the room is advantageous. 

 

In the event of a defect, do not attempt to repair the air conditioner yourself! 

 
 
 
 
 
Technical data: 

 

 
Model designation: 

 

 

 

 

WDH-FGA1075 

 

Energy efficiency rating (EER): 

 

 

A

 

 

Energy consumption per hour according to EER: 

1.115 kW/h 

 

Cooling capacity: 

 

 

 

 

10,000 BTU/h (2,930 watts)

 

 

Energy efficiency ratio (EER):  

 

 

2,6 

 

Unit type:

 

 

 

 

 

 

Cooling only 

 

Cooling type:

   

 

 

 

 

Air cooling

 

 

Noise emission:

 

 

 

 

 

65 dB(A)

 

 

Voltage: 

 

 

 

 

 

220-240V ~ 50Hz 

 

Max. Power consumption:

 

 

 

 

1,130 W (5.0 A) 

 

Power consumption in operating mode 
"Temperature controller off" (PTO): 

 

 

155 W 

 

Power consumption in standby mode (PSB):   

0,4 W 

 

Electricity consumption (QSD): 

 

 

1.12 kWh/a 

 

Air circulation:

  

 

 

 

 

350 m3/h 

 

Dehumidification capacity:

 

 

 

 

1.0 litre/h 

 

 

Range of use:

   

 

 

 

 

18°C - 32°C 

 

Compressor: 

 

 

 

 

 

Rotary compressor 

 

Refrigerant:

 

 

 

 

 

 

R290 (230 g)

 

 

Dimension (H/W/D):

 

 

 

 

 

770 x 317 x 402 mm

 

 

Dimension hot air duct:

 

 

 

 

Ø 150 x 1500 mm

 

 

Intake pressure:

 

 

 

 

 

0.85 Mpa 

 

Discharge pressure:   

 

 

 

2.2 Mpa

 

 

Weight:

 

 

 

 

 

 

25,5 kg 

 

The above data have been determined in accordance with EU standard: EN 14511, as well as EU safety and test regulations: EN 60335-2-40. 
COOLING - dry temperature = 35°C; wet temperature = 24°C 
Fuse: F2AL250V or T2AL250V 

 
 
 
 
 
 

Summary of Contents for WDH-FGA1075

Page 1: ...per transport can sometimes occur despite careful instructions on the carton Therefore we ask you to let it stand upright for at least 4 hours before using it for the first time so that the refrigeran...

Page 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Page 3: ...ust air cold 6 air filter 7 condensation drain 8 mains plug compartment 9 air intake 10 air intake Accessories 11 adapter for connecting the warm air hose with the window slit shutter bar 12 exhaust a...

Page 4: ...ng This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Page 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Page 6: ...gnal light when fan operation is activated h Signal light during dehumidification operation i Signal light when heating mode is activated inactive on this unit type j Signal light when the water tank...

Page 7: ...M Average operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating level you have just selected is indicated by a sma...

Page 8: ...es not included 9 Error display The air conditioner detects malfunctions and displays them in the unit s display panel If the display field shows E1 or E2 please contact your dealer 10 Other operating...

Page 9: ...zontally Now the condensation water can drain out of the tank 4 If your drip tray is full but there is still water in the condensation tank simply put the rubber plug back on the drain hole and then e...

Page 10: ...acent illustration Use the original carton to store the air conditioner Troubleshooting The unit does not switch on Check the mains plug and try a different socket Check if the house fuse has popped o...

Page 11: ...930 watts Energy efficiency ratio EER 2 6 Unit type Cooling only Cooling type Air cooling Noise emission 65 dB A Voltage 220 240V 50Hz Max Power consumption 1 130 W 5 0 A Power consumption in operatin...

Page 12: ...tage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under...

Reviews: