2.5. If you want to hold or freeze the currently determined measured value, press the Hold 
       key on the device. If you want to make a new measurement or if the holding/freezing is 
       no longer required, press the Hold key again and the device is released for new 
       measurements. 

 

2.6. To turn off the unit, press and hold the power button          for about two (2) seconds 
       Alternatively, the unit will automatically turn off after two (2) minutes of inactivity. 

 
 
Technical data: 

 

Model: 

 

WDH-318KC 

Power supply: 

 

9 V Battery 

Current consumption:

 

  <35 mA 

Measuring ranges: 

 

0% ~ 53% Softwood 

 

  0% ~ 35% Hardwood 

 

  Results of walls, ceilings, floors and masonries 

         correspond to the displayed relative values. 

Precision: 

 

± 4%

 

Max. measuring depth:

 

  20 mm 

Application range:

 

  0 ~ 40° C and 0 ~ 70% r.L. 

Measurements (H/W/D):

 

  170 x 75 x 30 mm

 

Weight:

 

  186 g (with Battery) 

 

The technical data are subject to change without notice !!

 

 
 
Troubleshooting: 
 

The instrument does not determine any measurement results or the measured value 
appears unrealistic: 
 
1.  Check the battery or make sure that there is sufficient battery voltage. 
> Repeat the measuring procedure. 
> If a measurement error occurs again: 
 
2.  Calibrate the instrument manually as follows. Switch on the instrument. Make sure that 

the rear measuring field on the instrument is clean, dry and free of contact. Now press 
the Hold button on your instrument until the display shows the value of 101%. Now 
release the Hold button on your device and a value of 102% should appear briefly in 
the display. Followed by 000%. Now your meter has been calibrated manually and 
should function properly again. 

 
 

Summary of Contents for WDH-318KC

Page 1: ...ity product So that you have much joy with this product here are a few hints In case of any problems We hope the device meets your expectations Should there be any reason for a complaint despite the greatest possible care we ask you to contact us briefly as we are very interested in your satisfaction and we would like to clear up any misunderstanding ...

Page 2: ...y with mild detergents Do not make any independent changes to the device Only qualified personnel are permitted to open the device Equipment and quality features Moisture display both as LCD value and as LED bar graph Measures unsealed materials and surfaces such as walls ceilings floors walls and wood Four different measuring modes can be selected Hardwood softwood stone walls and walls ceilings ...

Page 3: ... Hardwood Mode H Power button On Off B Softwoood Mode I Material selection button left C Masonary Mode J Measured value freeze key Hold D Wall Mode K Material selection button right E Battery warning symbol L Measured value frozen Symbol F Moisture measured value in percent M Measuring field G LED bar graph N Battery ...

Page 4: ... The object to be measured contains no metal o The object to be measured is not made of plastic o The object to be measured does not consist of different materials Make sure that the entire sensor surface of the device is always in full contact with the measured object 2 Operation Settings 2 1 Push the On Off button of you product The display light then lights up 2 2 Select with the left right arr...

Page 5: ...layed relative values Precision 4 Max measuring depth 20 mm Application range 0 40 C and 0 70 r L Measurements H W D 170 x 75 x 30 mm Weight 186 g with Battery The technical data are subject to change without notice Troubleshooting The instrument does not determine any measurement results or the measured value appears unrealistic 1 Check the battery or make sure that there is sufficient battery vo...

Page 6: ...e due to external influences use of force or foreign objects Damage caused by non observance of the operating instructions e g connection to an incorrect mains voltage or non observance of the installation instructions Completely or partially dismantled devices Conformity The meter and or parts thereof have been tested and manufactured to the following safety standards Naturally CE EMC compliant C...

Page 7: ...e Pb lead Cd cadmium Hg mercury Correct disposal of this product Within the EU this symbol indicates that this product must not be disposed of with household waste Old appliances contain valuable recyclable materials which should be recycled In addition the environment and human health should not be polluted by uncontrolled waste disposal Please dispose of Old appliances should therefore be collec...