ACV Measurement
The measurement is shown as in Figure 3-2, with voltage range being of AC 0.23V
~
1000V and the measurement methods
being as follows:
1.
Turn on the power switch and set the rotary switch to the position of .
2.
Insert the red and black testing lines into
VΩHz
end and
COM
end respectively.
3.
Press
FUNC.
key to select
AC
V measurement mode.
4.
Connect the meter to the two ends of the measured voltage with the red and black probes.
5.
Read the meter’s data from the display screen. When OL displaying on the meter, it indicates the measured voltage
exceeding the meter’s range and it is necessary to remove both the red and black probes from the measured circuit
immediately.
6.
By pressing the
RANGE
key it is possible to select range manually. Indicator of range displays range. While displaying OL
during manual range measurement, it is necessary to select a larger range. When OL displaying under the maximum range,
it indicates the voltage exceeding 1000V, so it is necessary to remove both the red and black probes from the measured
circuit immediately.
Notes: in case of probe hanging in the air, the voltage inducted by the testing line may cause unstable readings on the display screen, but
that will not affect the accuracy of measurement.
V
Summary of Contents for ??M-1130
Page 1: ...AMM 1130 USER S MANUAL www tmatlantic com...
Page 18: ...M 1130 18 Figure 3 2 AC Measurement Warning Not try to measure a voltage higher than 1000 Volt...
Page 20: ...M 1130 20 Figure 3 3 DC AC mV Measurement...
Page 22: ...M 1130 22 Figure 3 4 Logic Frequency Duty Ratio Measurement...
Page 24: ...M 1130 24 Figure 3 5 Resistance continuity Test Diode Measurement...
Page 26: ...M 1130 26 Figure 3 6 Capacitance Measurement...
Page 28: ...M 1130 28 Figure 3 8 DC AC A Measurement...
Page 30: ...M 1130 30 Figure 3 9 DC AC mA Measurement...