General Specifications 

Clamp jaw opening 

2.0" (52mm) approx. 

Display 

Dual 40,000/4,000 count backlit LCD 

Continuity check 

Threshold 50

; Test current < 0.5mA 

Diode test 

Test current of 0.3mA typical; 

 

Open circuit voltage 

[

 2.8VDC typical 

Low Battery indication

 

Battery symbol is displayed 

Over-range indication

 

‘OL’ display 

Measurement rate 

2 readings per second, nominal 

Peak detector 

>1ms 

Thermocouple sensor

 

Type K thermocouple required 

Input Impedance 

10M

 (VDC and VAC) 

Function 

Range& Resolution 

Accuracy (% of reading) 

DC Current 

400.00 ADC 

± (2.0% +30digits) 

1500.0 ADC 

± (2.5% +30digits) 

AC Current 

True RMS (50Hz to 60 Hz) 

400.00 AAC 

± (2.5% +30digits) 

1500.0 AAC 

± (2.8% +30digits) 

All AC voltage ranges are specified from 5% of range to 100% of range 

DC Voltage 

400.00 mVDC 

± (0.1% + 9digits) 

4.0000VDC 

± (0.1% + 4 digits) 

40.000 VDC 

400. 00 VDC 

1000.0 VDC 

± (0.5% + 4 digits) 

AC Voltage 

True RMS (50 Hz to 1000 Hz) 

400.0 mVAC 

± (0.8% + 9digits)(50/60Hz) 

4.0000 VAC 

± (1.0% + 30 digits) 

40.000 VAC 

400. 00 VAC 

750.0 VAC 

All AC voltage ranges are specified from 5% of range to 100% of range 

Resistance 

400.00 

Ω 

± (0.5% + 9 digits) 

4.0000K

Ω 

± (1.0% + 4 digits) 

40.000K

Ω 

400.00K

Ω 

4.0000M

Ω 

± (2.0% + 10digits) 

40.000M

Ω 

± (3.0% + 10 digits) 

Capacitance 

400.00nF 

±

(3.5% r 40digits) 

4000.0nF 

±

(3.5% r 10digits) 

40.000μF 

400.00μF 

4.0000mF 

±

(5% r 10 digits) 

20.000mF 
40.000mF 

Not specified 

Frequency 

 

40.000 Hz 

±

(0.3% r 2 digits) 

 

400.00 Hz 

4.0000KHz 
40.000KHz 
400.00KHz 

4.0000MHz 

40.000MHz 

Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 

20% to 80% duty cycle and > 100kHz. 

Duty Cycle 

10.0 to 95.0% 

±

(1.0% r 2 digits) 

Pulse width: 100µs - 100ms, Frequency: 10Hz to 100kHz 

Temp 

(type-K) 

(probe accuracy not included) 

-100.0 to 1000.0

°

±

(1.0% r 2.5 

°

C) 

-148.0 to 1832.0

°

±

(1.0% r 4.5

°

F) 

(probe accuracy not included) 

AC KW/kVA(0-600V,0-
1500A,50/60Hz TRMS) 

900.0kW 

± (3% +10digits) 

All AC voltage ranges are specified from 5% of range to 100% of range 

DC KW/kVA(0-600 V,0-1500A) 

900.0kW 

± (2.8 % +10digits) 

 

 

 

Summary of Contents for ACM-2352

Page 1: ...Clamp Watt Meter ACM 2352 USER S MANUAL...

Page 2: ...equipment SAFETY NOTES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set the function switch OFF when the meter is...

Page 3: ...button 5 MAX MIN button 6 INRUSH button 7 Backlit LCD Display 8 Non Contact Voltage Detector 9 NCV LED indicator 10 Function switch 11 KVA KW COS select button 12 Back light button 13 ZERO button 14...

Page 4: ...rent measurements To perform a zero select ADC and with no conductor in the jaw press the ZERO button The display will show zero The offset value is now stored and removed from all measurements Freque...

Page 5: ...egative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the device Touch the red test probe tip to the other side of the device...

Page 6: ...o the OFF position and then turn to the desired function position To disable APO 1 From the OFF position hold the MODE button and rotate the FUNCTION switch to a measurement function 2 will appear in...

Page 7: ...True RMS 50 Hz to 1000 Hz 400 0 mVAC 0 8 9digits 50 60Hz 4 0000 VAC 1 0 30 digits 40 000 VAC 400 00 VAC 750 0 VAC All AC voltage ranges are specified from 5 of range to 100 of range Resistance 400 00...

Page 8: ...ating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 7000ft 2000meters maximum Battery One 1 9V Battery NEDA 1604 Auto power OFF After a...

Reviews: