Aktakom ACM-2352 User Manual Download Page 3

www.tmatlantic.com 

  Expired or damaged batteries can cause cauterization on contact with the skin. Always, therefore, use suitable hand gloves in such 

cases 

  See that the batteries are not short-circuited. Do not throw batteries into the fire. 

 

Function 

Maximum Input 

A AC,  

1500A DC/AC 

A DC  

1500A DC/AC 

V DC, V AC 

1000V DC/AC 

Resistance, Capacitance, Frequency, Diode Test 

250V DC/AC 

Type K Temperature  

30V DC, 24V AC 

Description 

Meter Description 

1. 

Current clamp 

2. 

Clamp opening trigger 

3. 

 RANGE Button 

4. 

MODE button 

5. 

MAX/MIN button 

6. 

INRUSH  button 

7. 

Backlit LCD Display 

8. 

Non-Contact Voltage Detector 

9. 

NCV LED indicator 

10.  Function switch 

11.  KVA/KW/COS

θ

select button 

12.  Back light button 

13.  ZERO button 

14.  PEAK button 

15.  Multimeter input jacks 

 

 

 

 

 

 

Display icons Description 

HOLD 

Data Hold 

APO 

Auto Power Off 

AUTO 

Autoranging 

P

 

Peak Hold 

DC 

Direct Current  

AC 

Alternating Current 

MAX 

Max reading 

MIN 

Min reading 

 

Low battery 

ZERO 

DCA or CAP zero 

mV or V 

Milli-volts or Volts (Voltage) 

 

Ohms (Resistance) 

Amperes (Current) 

Farad (Capacitance) 

Hz 

Hertz (Frequency) 

Duty Ratio 

o

F and 

o

Fahrenheit and Celsius units (Temperature) 

n, m, 

µ

, M, k  Unit of measure prefixes: nano, milli, micro, mega, and kilo

 

)

)

Continuity test 

Diode test 

 

Summary of Contents for ACM-2352

Page 1: ...Clamp Watt Meter ACM 2352 USER S MANUAL...

Page 2: ...equipment SAFETY NOTES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set the function switch OFF when the meter is...

Page 3: ...button 5 MAX MIN button 6 INRUSH button 7 Backlit LCD Display 8 Non Contact Voltage Detector 9 NCV LED indicator 10 Function switch 11 KVA KW COS select button 12 Back light button 13 ZERO button 14...

Page 4: ...rent measurements To perform a zero select ADC and with no conductor in the jaw press the ZERO button The display will show zero The offset value is now stored and removed from all measurements Freque...

Page 5: ...egative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the device Touch the red test probe tip to the other side of the device...

Page 6: ...o the OFF position and then turn to the desired function position To disable APO 1 From the OFF position hold the MODE button and rotate the FUNCTION switch to a measurement function 2 will appear in...

Page 7: ...True RMS 50 Hz to 1000 Hz 400 0 mVAC 0 8 9digits 50 60Hz 4 0000 VAC 1 0 30 digits 40 000 VAC 400 00 VAC 750 0 VAC All AC voltage ranges are specified from 5 of range to 100 of range Resistance 400 00...

Page 8: ...ating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 7000ft 2000meters maximum Battery One 1 9V Battery NEDA 1604 Auto power OFF After a...

Reviews: