Operation 

NOTES

: Read and understand all 

Warning

 and 

Caution

 statements in this operation manual prior to using this meter. Set the function 

select switch to the OFF position when the meter is not in use. 
 

Non-Contact Voltage Detector 

WARNING:  

Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation

1. 

Rotate the Function switch to any measurement position. 

2. 

Place the detector probe tip on the conductor to be tested. 

3. 

If AC voltage is present, the NCV detector will turn on with a steady red light. 

NOTE

: The conductors in electrical cord sets are often twisted. For best results, move the probe tip along a length of 

the cord to assure placing the tip close to the live conductor. 

NOTE

: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip 

the sensor. This is normal operation.  

AC/DC Current Measurements  

 

WARNING: 

Disconnect the test leads before measuring with clamp. 

 

1. 

Rotate the Function switch to the 

1500A

AC/DC

 position. 

2. 

Press the 

MODE

 button to select AC or DC. 

3. 

Press the trigger to open  jaw. Fully enclose only one conductor. 

4. 

Read the current value in the display. 

5. 

If the value is less than 400A, rotate the function switch to the 

400A

AC/DC

 position to improve 

resolution. 

DCA Zero

 

The Zero feature removes offset values and improves accuracy for DC current 
measurements. To perform a zero, select A

DC,

 and, with no conductor in the jaw, press the ZERO 

button. The display will show zero. The offset value is now stored and removed  from all 
measurements. 

Frequency

 

When ACV is selected, the measured frequency can be viewed in the lower display. 

 

AC/DC Voltage Measurements

  

CAUTION: 

 Do not measure voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can 

damage the meter. 

 

1. 

Rotate the function switch to the 

position.  

2. 

Press the 

MODE

 button to select AC or DC Voltage. 

3. 

Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

4. 

Touch the black test probe tip to the negative side of the circuit.  
Touch the red test probe tip to the positive side of the circuit. 

5. 

Read the voltage value in the display. 

Frequency

 

When ACA is selected, the measured frequency can be viewed in the 
lower display. 

Resistance Measurements 

Note: Remove power from the device under test before measuring resistance. 

1. 

Set the function switch to the 

Ω 

position. 

2. 

Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

3. 

Touch the black test probe tip to one side of the device to be measured.  
Touch the red test probe tip to the other side of the device to be measured. 

4. 

Read the resistance value in the display. 

Continuity Test 

1. 

Connect

  

as described for resistance measurements. 

2. 

Press the 

MODE

 button to select continuity

)

)

)

3. 

Touch the test probe tips across the circuit or component under test. 

Summary of Contents for ACM-2352

Page 1: ...Clamp Watt Meter ACM 2352 USER S MANUAL...

Page 2: ...equipment SAFETY NOTES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set the function switch OFF when the meter is...

Page 3: ...button 5 MAX MIN button 6 INRUSH button 7 Backlit LCD Display 8 Non Contact Voltage Detector 9 NCV LED indicator 10 Function switch 11 KVA KW COS select button 12 Back light button 13 ZERO button 14...

Page 4: ...rent measurements To perform a zero select ADC and with no conductor in the jaw press the ZERO button The display will show zero The offset value is now stored and removed from all measurements Freque...

Page 5: ...egative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the device Touch the red test probe tip to the other side of the device...

Page 6: ...o the OFF position and then turn to the desired function position To disable APO 1 From the OFF position hold the MODE button and rotate the FUNCTION switch to a measurement function 2 will appear in...

Page 7: ...True RMS 50 Hz to 1000 Hz 400 0 mVAC 0 8 9digits 50 60Hz 4 0000 VAC 1 0 30 digits 40 000 VAC 400 00 VAC 750 0 VAC All AC voltage ranges are specified from 5 of range to 100 of range Resistance 400 00...

Page 8: ...ating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 7000ft 2000meters maximum Battery One 1 9V Battery NEDA 1604 Auto power OFF After a...