21
Akribis Systems GmbH
Am Weichselgarten 19a
T: +49 (0) 9131 811 79-0
E:
D-91058 Erlangen
F:
+49 (0) 9131 811 79-99
W:
4.3
Assembling voice coil table
The voice coil motor module is secured as standard from below.
•
Mounting holes in the mounting surface in accordance with dimensional
drawing (see Chapter 9)
•
Clean mounting surface
•
Position the voice coil motor module on the mounting holes.
•
Insert the mounting bolts in the mounting holes, and tighten them a crosswise
fashion, noting the maximum torque.
Any person installing or working near the voice coil table should
not have any items such as watch, credit card, keys etc. that
could be damaged by the magnetic field.
Strongly advised that personnel with heart pacer or medical
device that could be interfered by the strong magnetic field be
prohibited from handling these magnet tracks.
Warning
Danger from heavy loads!
Lifting heavy load may damage your health
Use a host of an appropriate size when positioning heavy loads!
Observe applicable occupational health and safety regulations
when handling suspended loads!
CAUTION
Be careful when sliding the motor from its shipping container.
Slide the motor from the box onto a flat, firm surface to prevent
bending. Bending can damage the magnets.
CAUTION
Danger from electrical voltage
Before and during assembly, disassembly and repair work,
dangerous currents may flow
Work may only be carried out by a qualified electrician and with the
power supply disconnected!
Before carrying out work on the voice coil table, disconnect the
power supply and protect it from being switched back on!
Danger