Thermometers
7.1.3.- Parameters
The unit's operation parameters are organized into groups or families according to their function.
The
def.
column shows factory-set default parameters. Those marked with an are variable depending on the
application chosen in the wizard (see section 3.1). Temperature values are expressed in ºC. (Equivalent temperature
in ºF)
Level 1.- Regulation and Control
*
Description
Values
Min
Def
Max.
A
B
C
D
E
SP
Temperature Adjustment (Set Point)
(limits depending on probe type) (Page 10)
(ºC/ºF)
NTC
-50
*
99
No Yes Yes
Yes Yes
PTC
-
150
No No
C0
Calibrating probe 1 (Offset) (Page 8)
(ºC/ºF)
-20.0
0.0
20.0 Yes Yes Yes Yes Yes
C1
Probe 1 differential (Histeresis) (Page 10)
(ºC/ºF)
0.1
2.0
20.0 No Yes Yes Yes Yes
C2
Upper blocking of the set point (Page 8)
(cannot be set above this value)
(ºC/ºF)
NTC
C3
99
99
No Yes Yes
Yes Yes
PTC
-
150
No No
C3
Lower blocking of the set point
(cannot be set below this value)
(Page 8)
(ºC/ºF)
-50
-50
C2
No Yes Yes Yes Yes
C4
Type of delay for protection of the compressor (Page 11):
0
=OFF/ON (since the last disconnection);
1
=ON (since start-up/reset);
2
=OFF-ON/ON-OFF (since the last shut-down /start-up)
0
0
2
No Yes Yes Yes Yes
C5
Protection delay time
(value of the option selected in parameter C4) (Page11)
(min.)
0
0
120
NO Yes Yes Yes Yes
D:
Available in
AKO-D14212 / D14220 / D14223 / D14312 / D14320 / D14323 / D14323-C / D10223 / D10323
C:
Available in
AKO-D14112 / D14123-2 / D14123-2-RC
E:
Available in
AKO-D14412-RC, AKO-D14423-RC
B:
Available in
AKO-D14120 / D14123 / D14124 / D14125 / D10123
Level 2
OUT OF
PROGRAMMING
PROGRAMMING
24
OK
< 5 sec.
< 5 sec.
< 5 sec.
> 5 sec.
> 5 sec.
> 5 sec.
SET
SET
SET