6- Table of parameters and messages
Def.
column shows factory-set default parameters. Those marked with
*
are variable parameters depending on the application chosen in the wizard or the P3 parameter (see table "Default
parameters by application"). Unless otherwise stated, temperatures are expressed in °C. (Equivalent velues in °F)
-50
(-58ºF)
C3
-50
(-58ºF)
-20.0
0.1
0
0
0
0
0
0
0
0
0
0
99
(210ºF)
99
(210ºF)
99
(210ºF)
150
(302ºF)
-
-
150
(302ºF)
-50
(-58ºF)
C2
0.0
20.0
2.0
20.0
255
0
120
0
3
10
120
5
120
96
5
255
0
1
2
2
0
2
SP
C0
C1
d1
EP
C2
C3
C5
C6
C7
C8
EP
d0
d3
d8
d2
C4
Temperature Adjustment (Set Point)
(limits depending on probe type)
With NTC
With NTC
Calibrating probe 1 (Offset)
Probe 1 differential (Histeresis)
Maximum defrost duration (
0
=defrost deactivated)
Exit to Level 1
Upper blocking of the set point
(cannot be set above this value)
Lower blocking of the set point (cannot be set below this value)
Protection delay time (value of the option selected in parameter C4)
Status of COOL relay with probe fault
0
=OFF;
1
=ON;
2
=Average based on last 24 hours prior to probe fault;
3
=ON-OFF as prog. C7 and C8 (in heat mode always OFF)
Time relay ON in case of faulty probe
(If C7=0 and C8
¹
0,
the relay will always be OFF deenergised)
Time relay OFF in case of fault of probe 1
(If C8=0 and C7
¹
0, the relay will always be ON energised)
Exit to Level 1
Defrost frequency
(Time between two starts)
Maximum duration of message
(time added at the end of the defrost)
Calculated time between defrost periods:
0
=Total actual time;
1
=Sum of times the compressor is on
Type of message during defrost:
0
=Current temperature;
1
=Temperature at start of defrost;
2
=Display dEF message
Type of delay for protection of the compressor:
0
=OFF/ON (since the last disconnection);
1
=ON (since start-up/reset);
2
=OFF-ON/ON-OFF (since the last shut-down /start-up)
(ºC/ºF)
(ºC/ºF)
(ºC/ºF)
(min.)
(ºC/ºF)
(ºC/ºF)
(min.)
(min.)
(min.)
(h.)
(min.)
With PTC
With PTC
Level1
Menus and description
Level 2
rE
Control
Level 3
Description
Values
Min. Def. Max.
Level 2
dEF
DEFROST Control (if P0=0 Direct, Cold)
Level 3
Description
Values
Min. Def. Max.
Temperature display mode
0
= Integer °C
1
=One decimal in ºC
2
=Integer °F
3
=One decimal in °F
0
1
3
P7
0
0
1
P9
Selection of probe type
0
=NTC;
1
=PTC
EP
Exit to Level 1
Nivel 2
tid
Control Acceso e Información
Nivel 3
Descripción
Valores Mín. Def. Máx.
L5
E1
dEF
MESSAGES
Access code (Password) request
Probe 1 faulty (open circuit, crossover,
NTC
: temp. >110°C or <-55 °C
PTC
: temp. >150 °C or <58 °C) - (equivalent limits in °F)
Indicates a defrost is underway. (Only if parameter d2=2)
0
0
0
255
1
P1
P0
Delay of all functions on receiving electrical power
Type of operation
0
=Direct, Cold;
1
=Inverted, Heat
Set the default parameters according to the type of application (see accompanying table)
1
=Multipurpose
2
=Frozen
3
=Fruit and Vegetables
4
=Fresh Fish
5
=Soft Drinks
6
=Bottle Racks
7
=AC
8
=Heat/Incubators
(min.)
Level 2
CnF
General status
Level 3
Description
Values
Min. Def. Max.
1
-
8
P3
P5
Address (only systems with built-in communications)
1
1
255
Level 2
Access and information control
Level 3
Description
Values
Min. Def. Max.
DEFAULT SETTINGS BY APPLICATION (P3)
2 (35,6ºF)
-18 (-0,4ºF)
10 (50ºF)
0 (32ºF)
3 (37,4ºF)
12 (53,6ºF)
21 (69,8ºF)
37 (98,6ºF)
20
0
20
0
20
0
20
0
20
0
20
0
0
0
-
1
4
4
4
4
24
24
96
-
SP
d1
P0
d0
8
Heat/
Incubators
4
Fresh Fish
6
Bottle Racks
7
AC
5
Soft Drinks
3
Fruit and
Vegetables
2
Frozen
1
Multipurpose
7- Technical specifications
Power supply
AKO-D14023/D14024/D14123/D14124/D14125
. 230 V~ ±10 % 50/60 Hz 3.5 VA
AKO-D14120
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 V~ +8 % - 12 % 50/60 Hz 4 VA
AKO-D14023-C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50/60 Hz 6 VA
AKO-D14012
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±20% 2.5 VA
Maximum Voltage SELV circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Comunication (Only AKO-D14023-C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modbus RTU RS485
Inputs (According to P4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 NTC/PTC
Relay COOL 16 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 12(9) A 250 V~)
Number of relay operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN60730-1: 100.000 operations
Types of probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NTC
AKO-149xx
/ PTC
AKO-1558xx
Measurement range NTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +99,9 ºC (-58,0 ºF to 211 ºF)
PTC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +150 ºC (-58,0 ºF to 302 ºF)
Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1 ºC
Working environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10 to 50 ºC, humidity <90 %
Ambient storage humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30 to 70 ºC, humidity <90 %
Class of protection - front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65
Fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Panel-mounted with anchors
Panel cutout dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 x 29 mm
Front panel dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 x 38 mm
Depth
AKO-D14023-C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 mm
Other models
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 mm
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw terminals for cables up to 2.5 mm²
Rating of control device: built-in, automatic operation feature Type 1.B, for use in clean environments,
Class A software and continuous operation. Pollution classification 2 s/ UNE-EN 60730-1.
Double insulation between supply, secondary circuit and relay output.
Rated pulse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 V
Temperature during ball-pressure test
Accessible parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 ºC
Parts which position active elements . . . . . . . . . . . . 125 ºC
Voltage and current as per EMC tests
AKO-D14023/D14023-C/D14024/
AKO-D14123/D14124/D14125/
. . . . . . . . . 207 V, 17 mA
AKO-D14120
. . . . . . . . . . . . . . . . . . . . . . . . 105 V, 36 mA
AKO-D14012
. . . . . . . . . . . . . . . . . . . . . . . 9,6 V, 181 mA
Current of radio jamming supression tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 m
A
90-260 V ~
~
12/24 V –
AKO-D14012, AKO-D14023, AKO-D14024
AKO-D14023-C
AKO-D14120, AKO-D14123, AKO-D14124, AKO-D14125
·
·
·
· ·
·
·
·
·
·
·
·
·
·
·
· ·
·
·
·
·
·
·
·
·
·
·
·
·
·
· ·
·
· ·
·
· ·
D
D:
Displays the message on the display
S:
Shows the message in the
AKO-5004
software
(Only
AKO-D14023-C
)
D
D
S
-
Change
Menu
Change
param.
Change
value
Programming Menu (parameters)
3 KEY EQUIPMENT
1 KEY EQUIPMENT
Level 1
Menu
Temperature
Indication
Temperature
Indication
Level 2
Parameters
Level 3
Values
OK
10 sec.
5 sec.
OK
OK
SET
SET
SET
SET
SET
20 sec.
20 sec.
20 sec.
OK
OK
SET
SET
OUT OF
PROGRAMMING
PROGRAMMING
After 20 seconds with no key being pressed, the equipment will return to the previous level. If you are on level 3, the changes will not be saved
Change
Menu
< 5sec.
Key pressed
several times
Key pressed
several times
< 5sec.
> 5sec.
> 5sec.
> 5sec.
> 5sec.
Change
param.
Level 1
Menu
Temperature
Indication
Level 2
Parameters
Level 3
Values
OK
10 sec.
OK
20 sec.
20 sec.
20 sec.
OK
OK
OUT OF
PROGRAMMING
PROGRAMMING
SET
SET
SET
SET
SET
SET
SET
SET
SET
< 5sec.
> 5sec.
Change
value OK
SET
SET
Temperature
Indication
Current
Value
New
Value
Change
value
Accept value
and Esc.
Change set point
(only equipment with three keys)
SET
-
-
0
-
99
L5
PU
Pr
EP
EP
Access code (Password)
Program version (Information)
Program revision (Information)
Exit to Level 1
Exit Programming
·
· ·
·
· ·
·
· ·
·
· ·
·
· ·
5.2- Setting parameters
WARNING:
The default parameters by type of application have been defined for the
most common applications. Check that these parameters are suitable for your
installation.
User Manual available at
www.ako.com
0
0
2
P2
Access code (password) functions
0
=Inactive;
1
=Block access to parameters;
2
=Keyboard lock
·
· ·