27
Description
Page
Units
Min
Def
Max.
Defrost at Start-up
16
No
Defrost delay at Start-up
16
(min.)
0
0
255
Signals end defrost time
16
No
Drip time
16
(min.)
0
1
255
Description
Page
Units
Min
Def
Max.
Fans stop temperature (controlled by probe 2)
(Probe 2 should be active)
17
(ºC/ºF)
–40.0
4.0
99.9
Fans differential s2
17
(ºC/ºF)
0.1
1.0
20.0
Stops when compressor OFF?
17
No
Fans state during defrost
Connected
Disconnected
17
Dis.
Fans delay after defrost
17
(min.)
0
3
255
Stop when opening door?
(It requires a digital input configured as door contact)
17
No
Description
Page
Units
Min
Def
Max.
Alarm configuration:
Relative to the SP
Absolute
19
Rel.
Maximum alarm in sensor 1 (limits according to the alarm configuration)
19
(ºC/ºF)
A. Min.
50.0
320
Minimum alarm in sensor 1 (limits according to the alarm configuration)
19
(ºC/ºF)
–40.0
50.0
A. Max.
Alarm differential
19
(ºC/ºF)
0.1
1.0
20.0
Temperature alarm delay
19
(min.)
0
30
255
Start-up alarm delay
19
(min.)
0
0
255
Alarm delay after defrost
19
(min.)
0
0
255
On-Off door alarm delay
19
(min.)
0
0
255
Off-On door alarm delay
19
(min.)
0
0
255
Alarm relay after key (After pressing the
ESC
key, alarm silenced):
Connected
Disconnected
19
Con.
FAN control
ALARM control