MEASUREMENT RESULTS
1) ADC part
[Measurement condition]
•
Measurement unit : Audio Precision, System two, Cascade
•
MCLK : 512fs at 48kHz, 256fs at 96kHz
•
BICK
:
64fs
•
fs :
48kHz,
96kHz
•
BW : 20Hz
∼
20kHz at fs=48kHz, 20Hz
∼
40kHz at 96kHz
•
Bit
:
24bit
•
Power Supply : AVDD=DVDD= TVDD=5V
•
Interface
:
DIT
(AK4118)
•
Temperature
: Room
a)
Single-ended Inputs
fs=48kHz
Parameter Input signal
Measurement filter
LIN1
RIN1
Units
S/(N+D)
1kHz,
-0.5dBFS
20kHz LPF
95.7
96.3
dB
DR
1kHz,
-60dBFS
20kHz LPF+A-weighted
102.7
102.6
dB
S/N
No signal
20kHz LPF+A-weighted
103.0
103.0
dB
fs=96kHz
Parameter Input signal
Measurement filter
LIN1
RIN1
Units
S/(N+D)
1kHz,
-0.5dBFS
40kHz LPF
91.6
92.3
dB
DR
1kHz,
-60dBFS
40kHz LPF+A-weighted
105.0
105.0
dB
S/N
No signal
40kHz LPF+A-weighted
105.2
105.2
dB
b)
Differential Inputs
fs=48kHz
Parameter Input signal
Measurement filter
LIN1
RIN1
Units
S/(N+D)
1kHz,
-0.5dBFS
20kHz LPF
96.9
96.7
dB
DR
1kHz,
-60dBFS
20kHz LPF+A-weighted
103.2
103.1
dB
S/N
No signal
20kHz LPF+A-weighted
103.5
103.5
dB
fs=96kHz
Parameter Input signal
Measurement filter
LIN1
RIN1
Units
S/(N+D)
1kHz,
-0.5dBFS
40kHz LPF
93.5
94.5
dB
DR
1kHz,
-60dBFS
40kHz LPF+A-weighted
105.9
105.7
dB
S/N
No signal
40kHz LPF+A-weighted
106.2
106.2
dB